Agilight SignRayz Ultra Mini Colors Скачать руководство пользователя страница 2

AgiLight Inc. 1074 Arion Circle, Suite 116, San Antonio, TX 78216, United States of America, +1.866.482.0203                  

www.AgiLight.com                

 

 

                                                                                                                                                                                                     

UL Installation Guide

 

© 2017 AgiLight Inc. 2017 All rights reserved.

 

  Product Specifications subject to change without notice.

 

  ING

-

00103     4

-

2017

 

Page 2 of 4

 

Wiring Instructions

 

1. Use appropriate wire connectors to 
cover the ends of exposed wires not 
being used as a connection point.

 

Note:

 

  *Have a licensed electrician make connections to primary (AC) input.

 

  *Per NEC 2008 Article 725.121 through 725.130, secondary class 2 cables do not 

 

    require conduit when installing.

 

  *Seal all wall penetrations with silicone to avoid intrusion of water.

 

Troubleshooting

 

Problem

 

Possible Cause

 

 

All LED modules are OFF or some of the LED 
modules are not illuminated.

 

1. Power supply may not be loaded properly with LED modules.

 

2. Wrong Power Supply. Must be constant current.

 

3. Bad or loose connections.

 

 

 

Entire section does not light or lights intermittently.

 

1. Bad, loose, or improper connections.

 

2. Power supplies are spaced too close together; overheating.

 

Note: Spacings between LED power supplies shall be at least 1 inch (25.4mm) 
from end to end, and 4 inches (101.6mm) from side to side.

 

 

 

LEDs flicker or appear dim.

 

1. Power supply may not be properly loaded with LED modules.

 

2. Power supply may be damaged or defective.

 

3. Power supply may not be wired correctly. Check AC input wiring.

 

(Green to Ground, Black to Black, and White to White).

 

2. To connect (splice) wires, use an 
in

-

line (IDC) connector, butt         

connector or a twist–on wire       
connector.

 

3. Connect the power supply to the 
product via the access hole in the 
sign

s back.

 

Power Supply Wiring Instructions

 

Model

 

Modules 60W

 

Single 

String

 

Parallel 

Strings 

Total

 

LS

-

UMIN

-

TRD

-

L4

-

50A

 

200

 

460

 

LS

-

UMIN

-

GRN

-

L4

-

50A

 

200

 

460

 

LS

-

UMIN

-

BLU

-

L4

-

50A

 

200

 

460

 

LS

-

UMIN

-

TRD

-

L4

-

35A

 

245

 

460

 

LS

-

UMIN

-

GRN

-

L4

-

35A

 

245

 

460

 

LS

-

UMIN

-

BLU

-

L4

-

35A

 

245

 

460

 

Power Supply Load Chart

 

Wire Size

 

Maximum Distance*

 

Gauge 

(AWG)

 

Metric 

 

(        )

 

Feet

 

Meters

 

26

 

0.13

 

3

 

0.9

 

24

 

0.21

 

4

 

1.2

 

22

 

0.33

 

7

 

2.1

 

20

 

0.52

 

11

 

3.4

 

18

 

0.82

 

18

 

5.5

 

16

 

1.31

 

29

 

8.8

 

14

 

2.08

 

45

 

13.7

 

12

 

3.31

 

71

 

21.6

 

10

 

5.26

 

120

 

36.6

 

LED Module to Power 
Supply  Wire Size

 

*Distance from 60 watt power supply to load at full capacity

 