Agilight SignRayz Ultra Mini Colors Скачать руководство пользователя страница 1

AgiLight Inc. 1074 Arion Circle, Suite 116, San Antonio, TX 78216, United States of America, +1.866.482.0203                  

www.AgiLight.com                

 

 

                                                                                                                                                                                                     

UL Installation Guide

 

© 2017 AgiLight Inc. 2017 All rights reserved.

 

  Product Specifications subject to change without notice.

 

  ING

-

00103     4

-

2017

 

Read Instructions Completely Before Installation. Altering The Product In Any Way Voids The Warranty.

 

Components:

 

 

1. AgiLight® Class II Power Supply

 

  2. AgiLight® SignRayz® ULTRA MINI COLORS modules

 

  3. Minimum 24 AWG (0.82mm) wire

-

(UL Listed)

 

      

*Under certain conditions, a heavier gauge wire may be necessary

 

  4. PLTC Cable

-

 (UL Listed)

 

  5. Wire connectors, wire nuts, IDC, or butt splice connectors (UL Listed)

 

Tools:

 

 1. Wire Strippers

 

 2. Screw Driver

 

 3. Taper Measurer

 

 4. Drill w/ 

(1/4” 

bit)

 

LED Module Installation

 

1.Clean inside of the sign with   
denatured alcohol. Allow alcohol to 
dry before proceeding.

 

2.Place LED modules in the sign 
according to AgiLight®  layout or 
Population Density Guide. Cut 
product accordingly 

 

*Product may be cut in between modules

 

WARNING–

 

READ BEFORE WIRING

 

1. Must use General LED

s Class 2 power supply rated for 12 volts DC or less; proper wire gauge to connect to LED modules.

 

2. Check polarity for DC standard, 

BLACK ( 

-

 ) to BLACK STRIPE ( 

-

 ) 

and 

RED ( + ) to WHITE ( + ).

 

3. UL 48 Standard requires a spacing between power supplies be at least 1 inch (25.4mm) from end to end, and 4 inches (101.6m m) from side to side.

 

4. Do not overload power supply and do not use products in submersed applications.

 

5. Ground and bonding of the LED power supply must be done in accordance with National Electric Code (NEC) Article 600.

 

6. Follow all National Electric Codes (NEC) and local codes.

 

Page 1 of 4

 

3.To adhere the LED module to the 
sign

s back panel, remove liner from 

tape and firmly press the module in 
place. Repeat process for the rest 
of the layout.

 

4.Drill a hole near the beginning 
of the string of LED modules and 
fit with an insulator for feeding 
power supply wire to the      
modules. 

 

*Access hold should be approximately 1/4 
inch (6.4mm) in diameter, minimum.

 

5.Remove debris and clean the inside 
of channel.

 

Tc cannot 

exceed 65°C

 

Отзывы: