background image

2

Agilent U7242A USB 3.0 Test Fixture User’s Guide

Notices

© Agilent Technologies, Inc. 2009

No part of this manual may be reproduced in 
any form or by any means (including elec-
tronic storage and retrieval or translation 
into a foreign language) without prior agree-
ment and written consent from Agilent 
Technologies, Inc. as governed by United 
States and international copyright laws.

Manual Part Number

U7242-97000

Edition

First edition, May 2009

Agilent Technologies, Inc.
1900 Garden of the Gods Road 
Colorado Springs, CO 80907 USA

Warranty

The material contained in this docu-
ment is provided “as is,” and is sub-
ject to being changed, without notice, 
in future editions. Further, to the max-
imum extent permitted by applicable 
law, Agilent disclaims all warranties, 
either express or implied, with regard 
to this manual and any information 
contained herein, including but not 
limited to the implied warranties of 
merchantability and fitness for a par-
ticular purpose. Agilent shall not be 
liable for errors or for incidental or 
consequential damages in connec-
tion with the furnishing, use, or per-
formance of this document or of any 
information contained herein. Should 
Agilent and the user have a separate 
written agreement with warranty 
terms covering the material in this 
document that conflict with these 
terms, the warranty terms in the sep-
arate agreement shall control.

Technology Licenses 

The hardware and/or software described in 
this document are furnished under a license 
and may be used or copied only in accor-
dance with the terms of such license.

Restricted Rights Legend

If software is for use in the performance of a 
U.S. Government prime contract or subcon-
tract, Software is delivered and licensed as 
“Commercial computer software” as 
defined in DFAR 252.227-7014 (June 1995), 
or as a “commercial item” as defined in FAR 
2.101(a) or as “Restricted computer soft-
ware” as defined in FAR 52.227-19 (June 
1987) or any equivalent agency regulation or 
contract clause. Use, duplication or disclo-
sure of Software is subject to Agilent Tech-
nologies’ standard commercial license 
terms, and non-DOD Departments and 
Agencies of the U.S. Government will 
receive no greater than Restricted Rights as 

defined in FAR 52.227-19(c)(1-2) (June 
1987). U.S. Government users will receive 
no greater than Limited Rights as defined in 
FAR 52.227-14 (June 1987) or DFAR 
252.227-7015 (b)(2) (November 1995), as 
applicable in any technical data.

Safety Notices

C A U T I O N

CAUTION

 notice denotes a haz-

ard. It calls attention to an operat-
ing procedure, practice, or the like 
that, if not correctly performed or 
adhered to, could result in damage 
to the product or loss of important 
data. Do not proceed beyond a 

CAUTION

 notice until the indicated 

conditions are fully understood and 
met. 

WA R N I N G

A WARNING notice denotes a 
hazard. It calls attention to an 
operating procedure, practice, or 
the like that, if not correctly per-
formed or adhered to, could result 
in personal injury or death. Do not 
proceed beyond a WARNING 
notice until the indicated condi-
tions are fully understood and 
met.

 

Содержание U7242A

Страница 1: ...Agilent Technologies U7242A USB3 0 Test Fixture User s Guide...

Страница 2: ...cribed in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of...

Страница 3: ...Test Fixture Description 5 Fixture and Accessories 6 Dimension 6 Characteristics Regulatory and Safety Information 7 Electrical Characteristics 7 Operating and Non operating Environmental Characterist...

Страница 4: ...4 Agilent U7242AUSB 3 0 Test Fixture User s Guide...

Страница 5: ...lps you to easily access the USB3 0 test signals The U7242A USB3 0 test fixture is required for the all the Far End TP1 tests including Far End Unit Internal test Far End SSC Slew Rate test Far End Te...

Страница 6: ...oard is as follows PCB board height 2 00 inches PCB board width 7 75 inches PCB board thickness 0 063 inches Part Number Description Quantity U7242 66501 USB 3 0 test fixture 1 unit 8121 1880 USB 3 0...

Страница 7: ...duct was tested in a typical configuration with HP Agilent test systems The following are the safety regulatory information of the U7237A 10GBASE T transmitter test fixture Description Specification T...

Страница 8: ...8 Minimum Requirement IEC 61010 1 Second edition 2001 2 EN 61010 1 2001 UL3111 1 or UL 6101B 1 2003 must be an Agilent ID Canada CSA C22 2 No 1010 1 1992...

Страница 9: ......

Страница 10: ...Agilent Technologies Inc 2009 First edition May 2009 U7242 97000 U7242 97000 www agilent com Agilent Technologies...