background image

7

 

Characteristics, Regulatory, and Safety Information

Electrical Characteristics

The following electrical characteristics are the specification of the U7242A 
USB3.0 test fixture:

Operating and Non-operating Environmental Characteristics

The following are the environmental characteristics of the U7242A USB3.0 
test fixture:

Safety Information

The U7237A 10GBASE- T transmitter test fixture herewith complies with 
the essential requirements of the Low Voltage Directive 73/23/EEC and the 
EMC Directive 89/336/EEC, and carries the CE- marking accordingly. The 
product was tested in a typical configuration with HP/Agilent test systems.

The following are the safety regulatory information of the U7237A 
10GBASE- T transmitter test fixture:

Description

Specification

Trace Impedance

100 ohm + 10%

Mated Connector

90 ohm + 10%

Cable

90 ohm + 10%

Description

Minimum Requirement

Ambient temperature

Operating = 0°C to 40°C 
Non-operating = - 51°C to 71°C

Humidity

Operating = 95% RH at 40°C for 24 hours

Altitude

Operating = 4,570m (15,000 ft)
Non-operating = 15,244m (50,000 ft)

Indoor use

This fixture is rated for indoor use only

Random vibration

HP/Agilent class B1 and MIL-PRF-2880 OF Class 3 random

Mechanical shock

HP/Agilent class B1 and MIL-PRF-2880 OF (operating 30g, 
1/2 sine, 11-ms duration, 3 shocks/axis along major axis. 
Total of 18 shocks)

Содержание U7242A

Страница 1: ...Agilent Technologies U7242A USB3 0 Test Fixture User s Guide...

Страница 2: ...cribed in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of...

Страница 3: ...Test Fixture Description 5 Fixture and Accessories 6 Dimension 6 Characteristics Regulatory and Safety Information 7 Electrical Characteristics 7 Operating and Non operating Environmental Characterist...

Страница 4: ...4 Agilent U7242AUSB 3 0 Test Fixture User s Guide...

Страница 5: ...lps you to easily access the USB3 0 test signals The U7242A USB3 0 test fixture is required for the all the Far End TP1 tests including Far End Unit Internal test Far End SSC Slew Rate test Far End Te...

Страница 6: ...oard is as follows PCB board height 2 00 inches PCB board width 7 75 inches PCB board thickness 0 063 inches Part Number Description Quantity U7242 66501 USB 3 0 test fixture 1 unit 8121 1880 USB 3 0...

Страница 7: ...duct was tested in a typical configuration with HP Agilent test systems The following are the safety regulatory information of the U7237A 10GBASE T transmitter test fixture Description Specification T...

Страница 8: ...8 Minimum Requirement IEC 61010 1 Second edition 2001 2 EN 61010 1 2001 UL3111 1 or UL 6101B 1 2003 must be an Agilent ID Canada CSA C22 2 No 1010 1 1992...

Страница 9: ......

Страница 10: ...Agilent Technologies Inc 2009 First edition May 2009 U7242 97000 U7242 97000 www agilent com Agilent Technologies...