U1701A Quick Start Guide

8

Power-On Options

To select power- on options, press and hold

while turning the ON/OFF switch to ON 

position. The power- on options are listed in 

Table 1- 1

How to Enter Setup Mode

Press and hold 

 and power on the instrument from OFF status. Release 

 

when 

you hear a beep, the instrument will then enter setup mode. These parameters will be 
remained in the non- volatile memory even after the instrument is turned off. To 
configure the related parameters on setup mode, ensure that the following procedures are 
followed: 

1

Press 

 (Left) or 

 (Right) to select the menu item to be set.

2

Press 

 (Up) or 

 (Down) to change the parameter.

3

Press 

 

to select the digit to be adjusted, the selected digit will flash. 

4

Press and hold 

 for more than 1 s to save your setting.

5

Press 

 

for more than 1 s to exit setup mode. 

Table 1-1

Power-On Options

Key

Description

HOLD

Demonstrate Annunciators

To demonstrate the annunciators, the entire annunciators will 
be displayed. Press any button to exit demonstration mode.

Reset the high and low limits to factory’s default values.

RANGE

Fast power off test for factory’s purpose

REL

To view the firmware revision

SET

Setup Mode

To configure related parameter, please refer to “How To Enter 
Setup Mode”.

Содержание U1701A

Страница 1: ...Agilent Technologies Agilent U1701A Dual Display Handheld Capacitance Meter Quick Start Guide...

Страница 2: ...he indicated conditions are fully understood and met WARNING WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not cor rectly performed or adher...

Страница 3: ...pacitance of more than 1000 F first discharge the capacitor then select a suitable range to measure it This will shorten the measuring time to achieve an accurate value Degradation of some product spe...

Страница 4: ...out of HI limit 13 Audible alert for tolerance and compare mode 5 Auto power off indicator 14 Unit for tolerance display 6 Tolerance mode to set 1 5 10 and 20 for sorting capacitance 15 Unit for Beepe...

Страница 5: ...ARD Guard terminal 4 Compare mode 5 TOL Tolerance mode 6 REL Relative mode 7 HOLD SAVE Data hold To store the setting value into the memory 8 RANGE AUTO Manual range Auto range 9 HI LO High Low limits...

Страница 6: ...n respectively to indicate which value is being displayed Press momentarily To exit the recording mode Press for more than 1 s To enable relative function Relative function shows the difference betwee...

Страница 7: ...ditions After setting the recording mode After setting the compare mode Display showing either OL or below 10 counts Press momentarily To exit tolerance mode Press and hold for more than 1 s To enable...

Страница 8: ...t The following buttons will be used for this setting mode a To select which digit to be adjusted b To increase or decrease the current digit s value c To select High or Low limit to be set d To store...

Страница 9: ...ocedures are followed 1 Press Left or Right to select the menu item to be set 2 Press Up or Down to change the parameter 3 Press to select the digit to be adjusted the selected digit will flash 4 Pres...

Страница 10: ...7 bits Stop bit is always 1 bit Echo oFF Echo on or oFF Prnt oFF Print on or oFF beep 4800 Driving frequency 4800 2400 1200 600 Hz oFF To disable beep LbUt oFF Lock buttons oFF Enable keypad on Disab...

Страница 11: ...Battery type Alkaline ANSI NEDA 1604A IEC 6LR61 Power consumption 5 6 mA Battery operation Battery life 80 hours without backlight based on new alkaline Operating temperature 0 C to 50 C Storage tempe...

Страница 12: ...t Range Resolution Accuracy The accuracy is specified to measure film capacitor or better and use relative mode to zero residual first Measuring rate as full scale approx 1000 0 pF 0 1 pF 1 10 5 times...

Страница 13: ...U1701A Quick Start Guide 12...