U1253A Quick Start Guide

Agilent U1253A True RMS OLED Multimeter

Quick Start Guide

The following items are included with your multimeter: 

Silicone test leads and alligator clips

Printed Quick Start Guide

CD containing the User’s and Service Guide, application software, and 
instrument drivers

Rechargeable 7.2 V battery

Power cord and AC adapter

Certificate of Calibration

If anything is missing or damaged, please contact the nearest Agilent 
Sales Office.

WA R N I N G

Ensure the terminal connections are correct for that particular measurement 
selection before starting any measurement. To avoid damage to the device, do not 
exceed the input limit.

Agilent Technologies

U1253A QSG.fm  Page 1  Tuesday, September 23, 2008  9:44 AM

Содержание U1253A

Страница 1: ...n software and instrument drivers Rechargeable 7 2 V battery Power cord and AC adapter Certificate of Calibration If anything is missing or damaged please contact the nearest Agilent Sales Office WARNING Ensure the terminal connections are correct for that particular measurement selection before starting any measurement To avoid damage to the device do not exceed the input limit Agilent Technologi...

Страница 2: ... or Ensure that is shown on the display 2 Connect the red and black test leads to input terminals V mV red and COM black respectively 3 Probe the test points and read the display 4 Press to display dual measurements Parameter can be switched consecutively Measuring AC current 1 Set the rotary switch to or Press to ensure is shown on the display 2 Connect the red and black test leads to input termi...

Страница 3: ... Set the rotary switch to 2 Connect the red and black test leads to input terminals red and COM black respectively 3 Connect the red test lead to the positive terminal of the capacitor and the black test lead to the negative terminal 4 Read the display Temperature 1 Set the rotary switch to Press to select temperature measurement 2 Connect the red and black test leads to input terminals red and CO...

Страница 4: ...ill be shown on the display This accommodates a higher frequency range of up to 20 MHz 6 The signal is out of the U1253A frequency measurement range of 20 MHz if the reading is still unstable after Step 5 Square Wave Output 1 Turn the rotary switch to 2 Press to select duty cycle on the primary display 3 The default square wave frequency is 600 Hz as shown by the secondary display with a 50 duty c...

Страница 5: ... Turns on dual display Press Starts manual data logging Press and hold for 1 s Views the logged data Press for 1 s press or to scroll through the logged data Clears the logged data Press for 1 s press for 1 s Measurement Functions Input Terminal Overload Protection Voltage COM 1000 Vrms Diode 1000 Vrms 0 3 A short circuit current Resistance Capacitance Temperature Current μA and mA µA mA COM 440 m...

Страница 6: ...cated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It calls atten tion to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated condi tions are fully understood and met Safety Symbols CAT III 1000 V Category III 1000 V overvolt...

Отзывы: