TriScroll 610 Dry Scroll Vacuum Pump
6
Electrical Connections
Wire the motor and electrical interlocks (if applicable) in accordance with local electrical codes and the relevant electrical
component manufacturer's instructions. Table 2 lists the full load motor currents in Amps at various voltages.
Table 2
TriScroll 610 Full Load Motor Currents
VAC
100
115
200
230
1 phase motor 50 Hz
14.0
13.6
7.0
6.8
1 phase motor 60 Hz
15.2
12.6
7.6
6.3
VAC
200
230
380
415
460
3 phase motor 50 Hz
4.4
4.4
2.2
2.2
-
3 phase motor 60 Hz
4.4
4.4
-
-
2.2