background image

TriScroll 610 Dry Scroll Vacuum Pump 

14

Factory Service Options

Agilent  offers  factory-rebuild  service  or  advance  exchange 

of 

complete  TriScroll  Pumps  or  Factory  Service  Options

(Table 7).

PTSS0600TS

Replacement Tip Seal 
Set

Replacement Tip Seals 
and static O-rings for 
TriScroll 600 series 
pumps.

Note: Maintenance 
Tool Kit required for 
tip seal replacement.

All TriScroll 600 and

610 models.

Table 6

Maintenance and Troubleshooting Kits (Continued)

Part Number

Description

Contents

Applicable TriScroll 

Model

Table 7

Factory Service Options

Model

Factory Service Options

EXPPTS06001

Advance Exchange TriScroll 600 Single Phase Pump

EXPPTS06003

Advance Exchange TriScroll 600 Three Phase Pump

EXPPTS06101

Advance Exchange TriScroll 610 Single Phase Pump

EXPPTS06103

Advance Exchange TriScroll 610 Three Phase Pump

EXPTS0600SC

Advance Exchange TriScroll 600 Pump Module Only

EXPTS0610SC

Advance Exchange TriScroll 610 Pump Module Only

PTS0600KMA

Service/Rebuild TriScroll 600 Pump (Single, or Three Phase)

TS0610KMA

Service/Rebuild TriScroll 610 Pump (Single, or Three Phase)

PTS0600SCRP

Service/Rebuild TriScroll 600 Pump Module Only

PTS0610SCRP

Service/Rebuild TriScroll 610 Pump Module Only

Содержание TriScroll 610

Страница 1: ...D R A F T 4 1 4 1 1 INSTALLATION AND OPERATION MANUAL Vacuum Products Division TriScrollTM 610 Dry Scroll Vacuum Pump Manual No 699904295 Revision F February 2005...

Страница 2: ...gilent Inc TriScroll 610 Dry Scroll Vacuum Pump TriScroll is a trademark of Agilent Loctite and PST are registered trademarks of Loctite Corporation Krytox Teflon and Viton are registered trademarks o...

Страница 3: ...ntents Contacting Agilent vi Specifications 1 Unpacking and Inspection 4 Installation 5 Safety 5 Electrical Connections 6 Operation 11 Start Up Procedure 11 Shutdown Procedure 11 Troubleshooting 12 Tr...

Страница 4: ...TriScroll 610 Dry Scroll Vacuum Pump This page intentionally left blank D R A F T 4 1 4 1 1...

Страница 5: ...ue se refiere esta declaraci n es conforme a la s norma s u otro s documento s normativo s waamaar deze verklaring verwijst aan de volende norm en of richtlijn en beantwoodt a cui se rifersce questa d...

Страница 6: ...Agilent In the United States you can contact Agilent Customer Service at 1 800 882 7426 See the back cover of this manual for a listing of our sales and service offices Visit our web site at http www...

Страница 7: ...nterface dimensions See Figure 2 on page 3 Peak pumping speed 50 Hz 420 I m 25 2 m3 hr 14 8 cfm 60 Hz 500 I m 30 m3 hr 17 6 cfm Ultimate pressure Torr 7 0 x 10 3 Torr 9 3 x 10 3 mbar Maximum inlet pre...

Страница 8: ...1 00 HP 0 75 kW 3 phase 50 Hz 200 230 380 415 VAC 3 Phase 60 Hz 200 230 460 VAC Motor full load currents See Table 2 Motor thermal protection Type N automatic Operating speed 1725 RPM 60 Hz 1425 RPM...

Страница 9: ...3 TriScroll 610 Dry Scroll Vacuum Pump Figure 2 TriScroll 610 Vacuum Pump Interface Drawing...

Страница 10: ...removing the foam packing and this manual slit open the inner box Lift the pump with plywood base out of the inner box Remove the four bolts securing the pump frame to the plywood base Locate the NW2...

Страница 11: ...se electric shock short circuits and severe bodily injury WARNING Before inspecting or servicing the pump be sure the electrical supply is disconnected Consult a qualified electrician when ever changi...

Страница 12: ...e relevant electrical component manufacturer s instructions Table 2 lists the full load motor currents in Amps at various voltages Table 2 TriScroll 610 Full Load Motor Currents VAC 100 115 200 230 1...

Страница 13: ...al cover in the groove provided The groove is sized for a 14 gauge cable A 1 2 14 NPSM hole is also provided next to the motor cover The clamp fitting is not provided 5 Wire L 1 and L2 per Figure 4 us...

Страница 14: ...rotation With the intake uncovered a large gas flow should come out the pump exhaust If there is no flow out the exhaust reverse any two of the leads L 1 L2 or L3 Repeat the test to verify correct rot...

Страница 15: ...Installation Data TriScroll Vacuum Pump VPI Valve Part NW25 VPI Valve Part NW40 Solenoid Operating Volt age Range Wiring Diagram 100 120 V 50 60 Hz 1 Phase VPI251205060 VPI401205060 90 132 V 50 60 Hz...

Страница 16: ...clamp and inlet O ring 3 Remove three 3 M5 screws item 1 on Figure 1 on page 1 that secure the cowling to the scroll module Remove the cowling 4 Tilt the pump back so that the rear end of the motor to...

Страница 17: ...g purge port item 6 on Figure 1 on page 1 is provided to protect the main crankshaft bearings in applications where large amounts of water are being pumped In the standard configuration the port is se...

Страница 18: ...ectrical cover Inspect and repair Wiring loose or cut Repair or replace Excessive voltage drop Check size and length of cable Defective motor Inspect Contact Agilent Poor ultimate pressure System leak...

Страница 19: ...0 series pumps are listed in Table 5 Maintenance and Tooling Kits Material and tooling required to perform maintenance on TriScroll pumps is provided in kit form A description of each kit and ordering...

Страница 20: ...Scroll Model Table 7 Factory Service Options Model Factory Service Options EXPPTS06001 Advance Exchange TriScroll 600 Single Phase Pump EXPPTS06003 Advance Exchange TriScroll 600 Three Phase Pump EXPP...

Страница 21: ...the core product e g inlet screens vent valves x Prior to shipment drain any oils or other liquids purge or flush all gasses and wipe off any excess residue x If ordering an Advance Exchange product...

Страница 22: ...ed or been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled...

Страница 23: ...Other Vacuum leak Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Prod...

Страница 24: ...TriScroll 610 Dry Scroll Vacuum Pump This page intentionally left blank...

Страница 25: ......

Страница 26: ...y Agilent Technologies Vacuum Products Division via F lli Varian 54 10040 Leini Torino ITALY Tel 39 011 997 9111 Toll Free 00 800 234 234 00 Fax 39 011 997 9350 Japan Agilent Technologies Vacuum Produ...

Отзывы: