background image

PGC 750 Speed Control Kit 

D

R

A

F

T

5

Refer to the manuals in Table 1-2 for more details of PGC-750 and inverter pump operation.

Table 1-1

Related Instruction Manuals

Description

Model

Manual no.

Pirani Capacitance Diaphragm 
Gauge

PGC-750

tqna77e1

TriScroll 300 inverter pump

PTS03001INV XX

699904355

TriScroll 600 inverter pump

PTS06001INV XX

699904360

Содержание PCG-750

Страница 1: ...D R A F T Vacuum Products Division PCG 750 Speed Control Kit Part No X3814 90002 Rev A April 2015 INSTALLATION MANUAL ...

Страница 2: ...D R A F T Copyright 2015 Agilent Inc PCG 750 Speed Control Kit ...

Страница 3: ...nd except as stated herein Seller shall have no liability under any warranty express or implied either in fact or by operation of law statutory or otherwise Statements made by any person including representatives of Seller which are inconsistent or in conflict with the terms of this warranty shall not be binding upon Seller unless reduced to writing and approved by an officer of Seller Warranty Re...

Страница 4: ...PGC 750 Speed Control Kit This page intentionally left blank D R A F T ...

Страница 5: ...tion Before operating or servicing equipment read and thoroughly understand all operation maintenance manuals provided by Agilent Be aware of the hazards associated with this equipment know how to recognize potentially hazardous conditions and how to avoid them Read carefully and strictly observe all cautions and warnings The consequences of unskilled improper or careless operation of the equipmen...

Страница 6: ...PGC 750 Speed Control Kit This page intentionally left blank D R A F T ...

Страница 7: ...erated only as specified CAUTION Disconnect the mains power before assembly and disassembly 1 Mount the Tee and PGC 750 as shown in Figure 1 1 with the NW 16 and NW 40 Quick Clamps Figure 1 1 Quick Clamps 2 Plug the communication cable DB9 connector labeled to PGC 750 into the PGC 750 gauge and plug the FCC 68 compliant connector into the inverter I O 3 Set the set points as specified in Setting t...

Страница 8: ...oint Screwdriver Adjustments When a set point is activated the corresponding open collector on pin 1 for set point 2 and on pin 2 for set point 1 becomes active and can sink current to the common ground This connection may be used to drive a relay coil or other indicator that shows the trigger set point has been reached Setpoint 1 Setpoint 2 ...

Страница 9: ...PGC 750 Speed Control Kit D R A F T 3 Figure 1 3 gives the output signal versus pressure graph and an explanation of how the results were generated Figure 1 3 Output Signal vs Pressure ...

Страница 10: ...PGC 750 Speed Control Kit 4 D R A F T Figure 1 4 gives a calibration curve for different gas types along with the calculation used to generate the curves Figure 1 4 Gas Type Dependence ...

Страница 11: ... more details of PGC 750 and inverter pump operation Table 1 1 Related Instruction Manuals Description Model Manual no Pirani Capacitance Diaphragm Gauge PGC 750 tqna77e1 TriScroll 300 inverter pump PTS03001INV XX 699904355 TriScroll 600 inverter pump PTS06001INV XX 699904360 ...

Страница 12: ...PGC 750 Speed Control Kit This page intentionally left blank D R A F T ...

Страница 13: ...core product e g inlet screens vent valves x Prior to shipment drain any oils or other liquids purge or flush all gasses and wipe off any excess residue x If ordering an Advance Exchange product please use the packaging from the Advance Exchange to return the defective product x Seal the product in a plastic bag and package product carefully to avoid damage in transit You are responsible for loss ...

Страница 14: ... been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled out Check boxes for all materials to which product s pumped or was exposed Toxic Corrosive Reactive Flammable Explosive Biological Radioactive List all toxic hazardous materials Include product name chemic...

Страница 15: ...er Vacuum leak Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Products and Services Terms of Sale x Customer is responsible for the freight charges for the returning product Return shipments must comply with all applicable Shipping Regulations IATA DOT etc and carrier r...

Страница 16: ...PGC 750 Speed Control Kit This page intentionally left blank ...

Страница 17: ......

Страница 18: ...an 54 10040 Leini Torino ITALY Tel 39 011 997 9111 Fax 39 011 997 9350 Toll Free 00 800 234 234 00 Japan Agilent Technologies Japan Ltd Vacuum Products Division 8th Floor Sumitomo Shibaura Building 4 16 36 Shibaura Minato ku Tokyo 108 0023 JAPAN Tel 81 3 5232 1253 Toll Free 0120 655 040 Fax 81 3 5232 1710 Korea Agilent Technologies Vacuum Products Division Shinsa 2nd Bldg 2F 966 5 Daechi dong Kang...