background image

   

10

                                                                                                                              

                            

N5101-90001  

Installing the Baseband Studio Software using the CD-ROM

The Baseband Studio software CD-ROM is no longer shipped with the N5101A Baseband Studio PCI card. The most 
recent versions of the Baseband Studio applications are only available by downloading them from the Agilent web site.

If you have the Baseband Studio software CD-ROM, you can install the older Baseband Studio versions of fading and 
waveform streaming without downloading them from the Agilent web site. This section contains the instructions for 
installing these older applications using the CD-ROM.

Licensing the Software

Baseband Studio applications require a license file to be fully functional. You will need to provide the following 
information to obtain the license file. 

1. Go to http://www.agilent.com/find/softwarelicense and follow the software license redemption process to obtain 

your license file. The license file will be e-mailed to you promptly. 

2. Copy the file into the following program directory:  C:\Program Files\Agilent\Baseband Studio\LicenseFiles

3.

Make a back-up copy of the license file and store it in a safe place. You will need this back-up file if the license file 
is lost or erased.

Installing the Software

1. If not already done, reconnect the AC power cable and turn on the PC.

The PC’s Found New Hardware wizard prompts you for a suitable driver, which is located on the Baseband Studio 
Software CD.

2. Insert the software CD into your PC’s CD-ROM drive.

3. In the Found New Hardware wizard, click 

Next

.

Follow the instructions in this wizard, and accept the driver N5101A.inf. If the wizard does not find the driver 
automatically, browse the driver folder on the CD and select it.

4. Locate AgilentBasebandStudioInstall.exe on the CD and run it. The Agilent Baseband Studio-InstallShield Wizard 

appears; click 

Next

, and follow the setup instructions. The Baseband Studio PCI card software installs.

5. If not already done, configure Agilent IO Libraries to include the signal source.

See 

“Configuring the Vector Signal Generator Using the LAN Interface” on page 11

 for an example using the LAN 

interface. Signal sources connected using GPIB are configured in a similar manner.

6. Run the Baseband Studio IO Config utility: This utility provides the system configuration and verification required 

by Baseband Studio applications. 

Start > Programs > Agilent Baseband Studio > Baseband Studio IO Config > IO Config

Follow the on-screen instructions. For details on using this utility, refer to the utility’s help. Run this utility 
whenever you make a change that could affect the configuration of the Baseband Studio PCI cards and instruments.

From the entitlement certificate:

From the N5101A PCI card

a

:

a. Applications are licensed to a specific PCI card; you may license more than one application to a given PCI card. 

Refer to 

page 3

 for the location of the bar code license number and the serial number.

Order Number

Certificate Number

PCI card Bar Code License Number

Instrument (Model) Serial Number (optional)

Содержание N5101A

Страница 1: ...internal PCI card hardware see page 6 for external cabling see page 8 4 Install the Baseband Studio PCI card driver see page 9 After the PCI card installation is complete the procedure directs you to...

Страница 2: ...06 Replaceable Parts of GPIO Bracket SMB to MCX Cable P N 8121 0655 Ribbon Cable Assembly P N N5101 60004 7 PCI card ISA Retainer Screws Retainer P N 1400 3295 Screws P N 0624 0858 2 each 4 SMB to SMB...

Страница 3: ...quire a license file to be fully functional The entitlement certificate shipped with your application purchase lists the products purchased and has two of the four numbers required to obtain the licen...

Страница 4: ...Application specific requirements Table 2 N5110A Baseband Studio for Waveform Streaming Streaming Rate Slow 5 MSa s Medium 20 MSa s Fast 40 MSa s Processor Pentium 4 2 GHz or greater Pentium 4 2 GHz o...

Страница 5: ...Dual Channel Configuration Two 32 bit 33 MHz and two additional PCI slot openings Operating System Windows XP Professional SP 1 or greater or Windows 2000 Professional SP 3 or greater Table 5 Require...

Страница 6: ...the GPIO bracket ribbon cable to J3 on the PCI card The remaining cables can be connected as shown either before or after you install the PCI card in the computer 2 For PCI compliant computer cases i...

Страница 7: ...shielding using the two screws provided See the illustration below The extender will slip into the guides at the front of the ISA compliant PC case as shown in the illustration above 5 Secure the rear...

Страница 8: ...s to ensure that they are clean 2 Connect a digital bus cable between each N5101A Baseband Studio PCI card and a source or N5102A Baseband Studio digital signal interface module connecting the end of...

Страница 9: ...seband Studio PCI Card page click the Baseband Studio PCI Card Driver link and follow the download instructions Application Software To install the Baseband Studio application software refer to the Ag...

Страница 10: ...Software CD 2 Insert the software CD into your PC s CD ROM drive 3 In the Found New Hardware wizard click Next Follow the instructions in this wizard and accept the driver N5101A inf If the wizard doe...

Страница 11: ...When you initially run a Baseband Studio application it looks for the required license file Configuring the Vector Signal Generator Using the LAN Interface Direct LAN Connection between PC and Vector...

Страница 12: ...ice 7 Enter the signal source s IP address a device name is not required 8 Click OK OK OK OK to close IO Config windows 9 As verification run the Agilent IO Libraries Visa assistant program Start Prog...

Страница 13: ...lect Properties In the Device status area you should see the message This device is working properly If not the N5101A Baseband Studio PCI card is probably not seated properly in the PC N5101A PCI Car...

Страница 14: ...internally using three MCX to MCX cables Agilent part number 8121 0620 These cables are not provided with the PCI card The cables have MCX male connectors on both ends They are connected as shown belo...

Страница 15: ...to contact your local Agilent office http www agilent com find assist If you do not have access to the Internet please contact your field engineer NOTE In any correspondence or telephone conversation...

Страница 16: ...ent web site search tool to search for the document part number Agilent N5101A Baseband Studio PCI Card Memory Upgrade Installation Note Agilent part number N5101 90003 Agilent Technologies Software I...