Chapter 1
55
Programming Fundamentals
Printer Setup and Operation
6. Press
Printer Type
to access the
Printer Type
menu keys. Press
Auto
to make
the analyzer attempt to identify the connected printer. When you press
Auto
,
the analyzer will respond in one of the three following ways:
•
The
Print Setup
menu will be displayed with the
Auto
key selected and no
new message will be displayed in the display status line. This indicates that
the analyzer has successfully identified the connected printer and no further
setup is required. As long as
Auto
remains selected in the
Printer Type
menu, the analyzer will attempt to identify the printer when the front panel
key is pressed.
•
The
Print Setup
menu will be displayed with the
Custom
key selected and
one of the following diagnostic messages will be displayed in the display
status line:
Unknown printer, Define Custom to set up printer
No printer response, Define Custom to set up
printer
Invalid printer response, Define Custom to set up
printer
This indicates that the analyzer was unable to automatically identify the
connected printer, and
Custom
has been selected in the
Printer Type
menu.
Press
Print Setup
,
Define Custom
to select specific printer characteristics
such as the printer language (PCL3 or PCL5) and color printing capability.
Once you have set these characteristics to match those of your connected
printer, the printer setup process is complete. As long as
Custom
remains
selected in the
Printer Type
menu, the analyzer will not attempt to
automatically identify the connected printer when the front panel
key
is pressed.
•
The
Print Setup
menu will be displayed with the
None
key selected and the
following message will appear in the display status line:
Unsupported printer, Printer Type set to None
This indicates that the analyzer has successfully identified the connected
printer, but the printer is not supported by the analyzer. As long as
None
is
selected in the
Printer Type
menu, the analyzer will respond to any print
command by displaying the message
Printer Type is None
in the
display status line.
Содержание E7401A
Страница 36: ...36 Commands Alphabetical Listing ...
Страница 92: ...92 Chapter 2 Status Registers Use Status Registers to Determine the State of Analyzer Events and Conditions ...
Страница 185: ...185 4 Programming Command Cross References ...
Страница 283: ...Chapter 5 283 Language Reference SENSe DETector Subsection Figure 5 4 Auto Rules of Detector Selection ...
Страница 339: ...339 6 Agilent 8590 EMC Analyzers Programming Conversion Guide ...