For example, in the figure above, the four Most Significant Bit (MSB) switches are shown in the "1" position,
the next bit is shown in the "0" position. The three Least Significant bit switches (shown in the "1" position)
are not used and may be in either the "1" or "0" position. Only the four Most Significant Bit address switches
need to be set for the 1 MByte modules; or five Most Significant Bit address switches for the 512 kByte
modules. Note: Ignore any numbering on the switch bank. Use the figure above to properly orient the address
switch.
Table 1-1. Memory Module Address Switch Settings
Module(s) being
installed:
Set one module’s address to:
("x" signifies a “Don’t Care” state)
Set the other module’s address to:
("x" signifies a “Don’t Care” state)
One
1
MByte
Module
MSB LSB
1 1 1 1 x x x x
Two
1MByte
Modules
MSB LSB
1 1 1 1 x x x x
MSB LSB
1 1 1 0 x x x x
One
512
kByte
Module
MSB LSB
1 1 1 1 1 x x x
Two
512
kByte
Modules
MSB LSB
1 1 1 1 1 x x x
MSB LSB
1 1 1 1 0 x x x
One 1 MByte Module and
One 512 kByte Module
Set the 1MByte module address to:
MSB LSB
1 1 1 1 x x x x
Set the 512 kByte module address to:
MSB LSB
1 1 1 0 1 x x x
Step 10: Set the memory module address switch(es) according to Table 1-1.
Address Switch
Installing Memory into an Agilent E1300B/E1301B Mainframe 1-7