ADM Flow Meter

Using the Flow Meter Stand

36

Agilent CrossLab CS ADM Flow Meter Operation Manual

Using the Flow Meter Stand

The flip down wire stand will give you a better viewing angle 
when the flow meter is placed above bench level. Pull the stand 
down until it is in the locked position.

Stand

Содержание CrossLab CS

Страница 1: ...Agilent CrossLab CS ADM Flow Meter Operation Manual...

Страница 2: ...y and fitness for a particular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or performance of this document or of any...

Страница 3: ...2 Operating Modes 13 Volumetric flow mode 13 Mass flow mode 13 Split mode 14 Info mode 14 Making a Flow Measurement 20 Storing Flow Measurements 21 Reading and Setting a Split Ratio 23 About Flow Meas...

Страница 4: ...eter cartridge 31 Replacing the Batteries 33 Upgrading the Firmware Retrieving Certificate of Calibration 35 Using the Flow Meter Stand 36 A Note About Backpressure 37 Technical Support 37 Other Featu...

Страница 5: ...n Power Mode button The Power Mode button is used to switch the flow meter on and off as well as to scroll through and select different operational modes To turn on the instrument briefly press and re...

Страница 6: ...to access additional functionality within the operating modes To store flow measurements in Volume mode and Mass mode briefly press and release Enter Clear toggle button To set a reference value in S...

Страница 7: ...y press and release Power Mode button to turn the unit on The screen will flash the words ADM Flow Meter for approximately three seconds then begin operating With the unit powered on press and hold th...

Страница 8: ...er purposes The measurement calibration can be affected if the instrument is exposed to temperatures above 50 C for extended periods of time Please inspect the temperature label attached to the inside...

Страница 9: ...on USB 5 V CC 0 5 A et le c ble USB fourni pour charger cet appareil N utilisez pas le d bitm tre ADM comme quipement de s curit ATTENZIONE Per caricare questo dispositivo utilizzare solo una fonte di...

Страница 10: ...mperature and pressure sensors installed in the mainframe of the flow meter The flow meter uses a replaceable cartridge that contains all parts subject to calibration This eliminates the need to ship...

Страница 11: ...ified at ambient temperature of 20 to 24 C 2 of reading or 0 2 mL min whichever is greater Accuracy 501 to 750 mL min 3 of reading Tubing Temperature Range 62 to 110 C Operating Temperature Range 0 to...

Страница 12: ...gth indicator The unit automatically adjusts the resolution of the display in response to various gas flow ranges as follows When the battery strength indicator shows that the battery strength is low...

Страница 13: ...The available modes are as follows Volumetric flow mode This is the default mode on power up In this mode the volumetric flow rate is displayed in mL min Mass flow mode In this mode the volumetric fl...

Страница 14: ...d control the Auto off functionality To access Info mode 1 With the unit switched on repeatedly press the Power Mode button until Info mode is displayed 2 Once in Info mode pressing the Enter Clear To...

Страница 15: ...usly until it is manually turned off In USB power mode the Auto off function is always off and the option to change the Auto off setting is disabled To change the Auto off setting 1 With Info mode dis...

Страница 16: ...arning code Type Description Troubleshooting 01 No Cal Info Error No calibration information Contact Agilent Technical Support 02 No Verif Error Flowmeter is not verified Contact Agilent Technical Sup...

Страница 17: ...ror Out of operating temperature range condition 0 to 45 C Operate the flow meter within the acceptable temperature range 11 Op Pres Error Out of operating atmospheric pressure range Operate the flow...

Страница 18: ...play cartridge information The first Cartridge screen displays the date information about the currently installed cartridge This includes the date that the cartridge was first used Activation date and...

Страница 19: ...ey number Key The key number is used to access the online copy of the cartridge s calibration certificate Mainframe information With Info mode displayed briefly press and release the Enter Clear Toggl...

Страница 20: ...the transducer NOTE Always turn the flow meter on before connecting it to a flow source 1 When the unit is powered on it defaults to volumetric flow mode If you want to use the mass flow mode briefly...

Страница 21: ...screen for reference later To store one or more values 1 With either volumetric flow mode or mass flow mode displayed briefly press the Enter Clear Toggle button The measurement storage screen appear...

Страница 22: ...Press the Enter Clear Toggle button to store a value to the first available slot 4 Repeat step 2 to store additional values to the subsequent slots Up to four values can be stored To clear the stored...

Страница 23: ...ratio 1 With the unit switched on repeatedly press the Power Mode button until Split mode is displayed NOTE Accurate column flow rates can only be determined when detector gases have been turned off...

Страница 24: ...ent CrossLab CS ADM Flow Meter Operation Manual 7 Adjust for the desired ratio by adjusting the flow of the split vent or the other reference flow until the required ratio is displayed To clear the st...

Страница 25: ...owever bubble type flow meters add water vapor to the gas being measured which introduces error into the flow rate measurement Even when accurately calibrated soap bubble meters typically read slightl...

Страница 26: ...e unit NOTE Using the USB port to supply power does not recharge the installed batteries The flow meter can communicate with a connected PC via the USB port Data from the flow meter can be collected b...

Страница 27: ...flow meter to your PC instrument sheet NOTE When using the data acquisition capability of the ADM flow meter you should disable the Auto off feature See Auto off on page 15 When the flow meter is bei...

Страница 28: ...een as appropriate Each is described below Warning indication A warning icon appears on the screen when the flow meter is being operated outside of acceptable conditions when the filter is expired whe...

Страница 29: ...nt CrossLab CS ADM Flow Meter Operation Manual 29 Low battery indication When the batteries need to be replaced a low battery indication is displayed on the screen When power is too low for operation...

Страница 30: ...ADM Flow Meter Operation Manual Power Indications The flow meter can be powered by batteries or through the USB port When powered by batteries a battery icon will appear on the screen When powered th...

Страница 31: ...ectronic Leak Detector Cartridge P N G6694A NOTE If you purchased the leak detector cartridge standalone update your existing mainframe to the latest firmware when using your leak detector for the fir...

Страница 32: ...tridge with ADM flow meter cartridge 32 Agilent CrossLab CS ADM Flow Meter Operation Manual 3 Insert cartridge of ADM flow meter in to the CrossLab CS Mainframe body Hand tighten the two captive thumb...

Страница 33: ...ries in accordance with all applicable governmental requirements for your location To replace the batteries do the following 1 Press and hold the Power Mode button for three seconds to power off the f...

Страница 34: ...Flow Meter Operation Manual 3 Remove and replace the three AA batteries 4 Reinstall the battery cover Position the battery cover over the batteries and slide onto the flow meter until it locks in plac...

Страница 35: ...the flow meter firmware is available you can upgrade to the latest version using your PC via the USB connection of the ADM flow meter Please visit http www agilent com chem ADMflowmeter for instructi...

Страница 36: ...ilent CrossLab CS ADM Flow Meter Operation Manual Using the Flow Meter Stand The flip down wire stand will give you a better viewing angle when the flow meter is placed above bench level Pull the stan...

Страница 37: ...transducer creates an ever so small backpressure that compresses the gas slightly Technical Support Agilent s Technical Support Specialists are chemists with years of laboratory experience They can pr...

Страница 38: ...tic Compatibility EMC and Radio Frequency Interference RFI CISPR 11 EN 55011 Group 1 Class A IEC EN 61326 1 This ISM device complies with Canadian ICES 001 A Cet appareil ISM est conforme a la norme N...

Страница 39: ...39 Agilent CrossLab CS ADM Flow Meter Operation Manual This page intentionally left blank...

Страница 40: ...www agilent com Agilent Technologies Inc 2021 Third edition December 2021 G6691 90000 G6691 90000...

Отзывы: