background image

5

Quick Comparison of Agilent Technologies 30W to 200W Low Power DC Power Supplies

Features

E363XA

E364XA

661XC

663XB

664XA

No. of Models

4

10

4

4

5

Delivery

< 1 week, typically

< 1 week, typically

1 week

1 week

1 week

No. of Outputs

1 or 3

1 or 2

1

1

1

Applications

Semi-automated 

Moderate speed

High performance

High performance

High performance

general purpose 

semi-automated and

automated production

automated production

automated production

bench testing

automated production  test

test

test

test

Size

Half rack, 3U

Half rack, 2U/3U

Half rack, 2U

Full rack, 2U

Full Rack, 2U

Connections

E3631/2A, Front only 

Front & rear

Rear only

Rear only

Rear only

E3633/4A, Front & rear 

Programming

GPIB and RS-232

GPIB and RS-232

GPIB and RS-232

GPIB and RS-232

GPIB only

Programmable No

No

Yes

Yes

Yes

Wakeup State

Throughput Capabilities

Output rise/fall

130 to 550 ms

<90 ms

6 ms

6 ms

35 ms

Transient Response

<50µs for output to 

<50µs for output to

100µs(50µs in the

100µs(50µs in the

100µs for output

recover within 15mV 

recover within 15mV

fast mode) for output

fast mode) for output

voltage to recover

following a change in 

following a change

voltage to recover

voltage to recover

from zero to full load

output current

in output current 

from zero to full load 

from zero to full load

within 20mV

within 20mV

within 20mV

DFI/RI

Relay control available  Relay control available Allows shut down of

Allows shut down of

Allows shut down of

from pin 1 of RS-232 

from pin 1 of RS-232

multiple supplies or

multiple supplies or

multiple supplies or

connector

connector

other h/w, provides for  other h/w, provides

other h/w, provides

output relay control

for output relay control for output relay control

Active Down 

No

No

Yes

Yes, negative current is Yes, sinks 20% of rated

programmer

programmable.

output current.

Performance

Ripple and Noise 

2 – 3mVpp/0.35 –

<5mVpp/0.5mVrms for 3mVpp/0.3mVrms for

3mVpp/0.3mVrms for

3mVpp/300mVrms for

(20 Hz to 20 MHz)

0.5mVrms

8V/20V models

8V/20V models

8V/20V models

8V/20V models

<8mVpp/1mVrms for

3mVpp/0.5mVrms for

3mVpp/0.5mVrms for

4mVpp/400mVrms for

35V/60V models

50V model

50V model

35V model

3mVpp/0.5mVrms for

3mVpp/0.5mVrms for

5mVpp/500mVrms for

100V model

100V model

60V model
7mVpp/700mVrms for 
120V model

Line/Load Regulation

Voltage <0.01% + 2mV Voltage <0.01% + 3mV Voltage 0.5mV – 5 mV

Voltage 0.5mV – 5 mV

Voltage 0.5mV – 5 mV

Current <0.01% + 250mA Current <0.01% + 250mA Current 0.25mA – 1mA

Current 0.25mA – 1mA Current 0.25mA – 1mA

Remote Sensing

Can drop up to 0.7V 

Can drop up to 1V in

Can drop up to 2V in

Can drop up to 2V in

Can drop up to 2V in

in each load lead

each load lead

each load lead

each load lead

each load lead

E3631A, None

Meters

4 or 5 digit voltage/

4 digit

4 digit

4 digit

4 digit

4 digit current

Отзывы: