2 - Verification and Performance Tests
12
Resistor
(substitute for electronic
load if load is too noisy
for CC PARD test)
1 ohm, 50 W
3 ohm, 100 W (Agilent 66332A/6632B)
24 ohm, 100 W (Agilent 6633B)
99 ohm, 100 W (Agilent 6634B)
1k ohm, 5%, 3W (all models)
Ohmite L50J1R0
Ohmite RLS5R0 (adjustable)
Ohmite RLS25R (adjustable)
Ohmite RLS100 (adjustable)
Agilent 0813-0001
Oscilloscope
Sensitivity: 1 mV
Bandwidth Limit: 20 MHz
Probe: 1:1 with RF tip
Agilent 54504A or equivalent
RMS Voltmeter
True RMS
Bandwidth: 20 MHz
Sensitivity: 100
µ
V
Agilent 3400B or equivalent
Variable-Voltage
Transformer
Adjustable to highest rated input voltage range.
Power: 500 VA
Measurement Techniques
Test Setup
Most tests are performed at the rear terminals of the supply as shown in Figure 2-1a. Measure the dc voltage directly
at the +S and -S terminals.
Figure 2-1. Test Setup
Load
resistor
DC
Ammeter
-
+
Load
resistor
DC
Ammeter
-
+
+
-
External
DC supply
b.
c.
+S
+
-
-S
+ 240 VDC MAX
-
+S
+
-
- S
+ 240 VDC MAX
-
+S
+
-
-S
+ 240 VDC MAX
-
a.
DVM or
Current
monitor
RMS voltmeter
-
+
Electronic
-
+
DVM, Scope, or
-
+
RMS voltmeter
Load
(for CV tests)
(for CC tests)
Note: Use dc supply with same polarity
connections for - CC tests.
Replace load with appropriate
resistor for CC noise test.
(see note)
1 k ohm
400 ohm
Содержание 6632B
Страница 8: ......
Страница 27: ...Troubleshooting 3 27 Figure 3 1 Sheet 3 Main Flowchart continued...
Страница 49: ...Principles of Operation 4 49 Figure 4 1 A2 A3 Block Diagram...
Страница 51: ...Principles of Operation 4 51 Figure 4 2 A1 Block Diagram...
Страница 54: ......
Страница 57: ...Replaceable Parts 5 57 Figure 5 1 Mechanical Parts ldentification...
Страница 75: ...Figure 6 1 A1 Board Component Locations...
Страница 76: ...Figure 6 2 A4 and A6 Board Component Locations...
Страница 77: ...Figure 6 3 A1 Board schematic sheet 1...
Страница 78: ...Figure 6 3 A1 Board schematic sheet 2...
Страница 79: ...Figure 6 3 A1 Board schematic sheet 3...
Страница 80: ...Figure 6 4 A6 Relay Option Board schematic...