3 - Troubleshooting
36
Disable the OV capability by
shorting R351. After the
protection is disabled, program
the output voltage to zero,
current to full scale and Output
ON. If the unit is in "Protect"
mode, Press Protect Clear. The
output should now go high and
not trip the OV.
Is the CV
annunciator on
?
Vmon,
U315B-7,
OK ?*
No
Check Voltage Monitor
Amplifier, U315B
circuit
No
CV_Prog,
R401
~0V
?
Yes
A2 Interface Board
No
Check Voltage Control
U315A, circuit
Yes
Voltage <0.6V
?
Measure voltage at the
base of Q303 with
respect to its' emitter
Yes
Troubleshoot Voltage
Gain Stage
No
Troubleshoot Output
Stage
Yes
* V_mon should be approximately
6632B or 66332A Vout/4.25
6633B Vout/10.52
6634B Vout/21
Figure 3-1 Sheet 12. High Output Voltage