FINAL
TRIM
SIZE
:
7.5
in
x
9.0
in
Calibration
Overview
User
Calibrations
Channel
Skew
Calibration
The
skew
calibration
changes
the
horizontal
position
of
a
waveform
on
the
display
.
The
skew
calibration
has
a
range
of
approximately
100
s
.
Y
ou
can
use
skew
to
compensate
for
the
dierences
in
cable
or
probe
lengths
.
It
also
allows
you
to
place
the
trigger
edge
at
the
center
of
the
display
when
you
are
using
a
power
splitter
connected
between
the
channel
and
trigger
inputs
.
Another
use
for
skew
is
when
you
are
comparing
two
waveforms
that
have
a
timing
dierence
.
If
you
are
interested
in
comparing
the
shapes
of
two
waveforms
rather
than
the
actual
timing
dierence
,
you
can
use
skew
to
overlay
one
waveform
on
top
of
the
other
waveform.
T
o
skew
two
channels
1.
Turn
both
channels
on
and
overlay
the
signals
vertically
.
2.
Expand
the
time
base
so
that
the
rising
edges
are
at
about
a
45
angle
.
3.
Press
the
plug-in
module's
front-panel
channel
4
SETUP
5
key
.
4.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Calibrate
and
then
NNNNNNNNNNNNNN
Skew
.
5.
A
djust
the
skew
on
one
of
the
channels
so
that
the
rising
edges
overlap
at
the
50%
points
.
Probe
Calibration
F
or
active
probes
such
as
the
Agilent
54701A,
which
the
instrument
can
identify
through
the
probe
power
connector
,
the
instrument
automatically
adjusts
the
channel
vertical
scale
factors
to
the
probe's
nominal
attenuation,
even
if
a
probe
calibration
is
not
performed.
F
or
passive
probes
or
non-identied
probes
,
the
instrument
adjusts
the
vertical
scale
factors
only
if
a
probe
calibration
is
performed.
Probe
calibration
allows
the
instrument
to
establish
the
gain
and
oset
of
specic
probes
that
are
connected
to
a
channel
of
the
instrument,
and
then
apply
those
factors
to
the
calibration
of
that
channel.
3-10
Содержание 54751A
Страница 1: ......
Страница 2: ...FINAL TRIM SIZE 7 5 in x 9 0 in User s Guide Agilent 83483A 4A 4B and 54751A 2A 2B Plug In Modules ...
Страница 8: ...FINAL TRIM SIZE 7 5 in x 9 0 in Declaration of Conformity vii ...
Страница 9: ...FINAL TRIM SIZE 7 5 in x 9 0 in viii ...
Страница 15: ...FINAL TRIM SIZE 7 5 in x 9 0 in Contents ...
Страница 16: ...FINAL TRIM SIZE 7 5 in x 9 0 in 1 The Instrument at a Glance ...
Страница 22: ......
Страница 25: ...FINAL TRIM SIZE 7 5 in x 9 0 in TheInstrumentata Glance ...
Страница 26: ...FINAL TRIM SIZE 7 5 in x 9 0 in 2 Channel Setup Menu ...
Страница 28: ...FINAL TRIM SIZE 7 5 in x 9 0 in ChannelSetupMenu Figure2 1 ElectricalChannel Setupmenu 2 3 ...
Страница 38: ...FINAL TRIM SIZE 7 5 in x 9 0 in 3 Calibration Overview ...
Страница 52: ...FINAL TRIM SIZE 7 5 in x 9 0 in 4 Speci cations and Characteristics ...
Страница 60: ......
Страница 67: ...FINAL TRIM SIZE 7 5 in x 9 0 in InCaseofDi culty ...
Страница 68: ...FINAL TRIM SIZE 7 5 in x 9 0 in Index ...
Страница 73: ...FINAL TRIM SIZE 7 5 in x 9 0 in ...