Calibration
Overview
User
Calibrations
T
able
3-3.
Miscellaneous
User
Calibration
Summary
Calibration
What
is
calibrated
Measurements
Aected
Recommended
Interval
K
ey
Path
Probe
calibration
Probe
Attenuation
An
y
electrical
measurement
taken
with
the
probe
Whenever
a
probe
is
connected
4
Electrical
Channel
Setup
5
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
probe
Channel
Skew
Calibrates
out
the
small
dierences
in
dela
y
between
channels.
Useful
for
looking
at
timing
dierences
between
channels
Multiple
channel
measurements
Before
multiple
channel
measurements
when
measuring
timing
dierences
between
channels.
4
Channel
Setup
5
FFFFFFFFFFFFFFFFFFFFFFFFFF
Calibrate
FFFFFFFFFFFFF
Skew
External
Scale
Compensates
for
gain
or
loss
associated
with
external
devices
(calibrates
vertical
scale
to
external
device)
An
y
measurement
taken
through
an
external
device
(component
or
transducer)
Whenever
using
external
devices
(component
or
transducer)
4
Channel
Setup
5
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
External
Scale
Plug-in
Module
V
ertical
Calibration
The
plug-in
module
vertical
calibration
allows
the
instrument
to
establish
the
calibration
factors
for
a
specic
plug-in
when
the
plug-in
is
installed
in
the
mainframe
.
The
plug-in
calibration
factors
are
valid
only
for
the
specic
mainframe
slot
in
which
it
was
calibrated.
The
plug-in
vertical
calibration
establishes
vertical
accuracy
.
A
plug-in
vertical
calibration
should
be
done
if:
The
mainframe
has
cycled
power
.
The
plug-in
has
been
repaired,
reprogrammed,
or
removed
from
the
mainframe
.
The
instrument's
operating
temperature
has
changed
and
remains
more
than
5
C
from
the
temperature
at
which
the
Plug-in
calibration
was
performed.
3-7
Содержание 54751A
Страница 1: ......
Страница 2: ...FINAL TRIM SIZE 7 5 in x 9 0 in User s Guide Agilent 83483A 4A 4B and 54751A 2A 2B Plug In Modules ...
Страница 8: ...FINAL TRIM SIZE 7 5 in x 9 0 in Declaration of Conformity vii ...
Страница 9: ...FINAL TRIM SIZE 7 5 in x 9 0 in viii ...
Страница 15: ...FINAL TRIM SIZE 7 5 in x 9 0 in Contents ...
Страница 16: ...FINAL TRIM SIZE 7 5 in x 9 0 in 1 The Instrument at a Glance ...
Страница 22: ......
Страница 25: ...FINAL TRIM SIZE 7 5 in x 9 0 in TheInstrumentata Glance ...
Страница 26: ...FINAL TRIM SIZE 7 5 in x 9 0 in 2 Channel Setup Menu ...
Страница 28: ...FINAL TRIM SIZE 7 5 in x 9 0 in ChannelSetupMenu Figure2 1 ElectricalChannel Setupmenu 2 3 ...
Страница 38: ...FINAL TRIM SIZE 7 5 in x 9 0 in 3 Calibration Overview ...
Страница 52: ...FINAL TRIM SIZE 7 5 in x 9 0 in 4 Speci cations and Characteristics ...
Страница 60: ......
Страница 67: ...FINAL TRIM SIZE 7 5 in x 9 0 in InCaseofDi culty ...
Страница 68: ...FINAL TRIM SIZE 7 5 in x 9 0 in Index ...
Страница 73: ...FINAL TRIM SIZE 7 5 in x 9 0 in ...