background image

21

16allp17

When a system is shipped, the factory installs the current operating system

and ordered processor support packages and tools.

Software Installation

for 16700B/ 16702B/ Measurement Modules

Содержание 16700B

Страница 1: ...Copyright Agilent Technologies 2000 All Rights Reserved Logic Analysis Systems Publication Number 16700 97014 16allp01 Installation Guide 16700B Measurement Modules 16702B...

Страница 2: ......

Страница 3: ...Proper Cooling Monitor Connection Monitor Configuration 16700B 6 8 7 9 Changing Monitors Printers Software Installation LAN 16701A B Expander Frame Probing Self Test Specifications Characteristics Dis...

Страница 4: ...Power Cable 16701A B Expander Frame 16allp04 Making Basic Measurements If ordered Monitor Monitor Cable Monitor Power Cable 16700B Mainframe Training Board and Training Kit External Disk Drive and Cab...

Страница 5: ...1A B Expander Frame 16allp05 Monitor Monitor Cable and Monitor Power Cable If ordered Making Basic Measurements Mouse and Keyboard Training Board and Training Kit 16702B Overview External Disk Drive a...

Страница 6: ...ol Keyboard Mouse Keyboard Mouse 6 16700B or 16702B 16allp06 Mouse Keyboard for 16700B 16702B The 16700B must have the system mouse and keyboard connected for the system to boot up properly Once enabl...

Страница 7: ...ame Target Control Target Control Keyboard Mouse 7 16700B or 16702B 16allp07 If applicable international versions of the power cables can be found in the accessories box Monitor Power Cable Optional f...

Страница 8: ...Power Busy 8 Allow a minimum of 5 cm spacing between instruments for proper cooling 16allp08 Power Busy 5cm 5cm 5cm 5cm 16700B Proper Cooling for 16700B 16702B Measurement Modules 16702B...

Страница 9: ...a monitor and ordered your logic analysis system without the optional monitor you will need to configure your monitor The display will change on the screen every few seconds as the system cycles throu...

Страница 10: ...o an 16702B Enter Press ENTER to select the monitor choice and Y to confirm Monitor power 1 System power 3 4 Immediately press the TAB key about ten times Tab Tab Tab Tab Tab Tab Tab Tab Tab Tab Tab C...

Страница 11: ...oice and Y to confirm Monitor power 1 3 4 Immediately press the TAB key about ten times Tab Tab Tab Tab Tab Tab Tab Tab Tab Tab System power 2 16700B 16702B Different Monitor Cycling choices Monitor c...

Страница 12: ...12 16allp12 Help 10Base T 100Base TX 16700B or 16702B LAN for 16700B 16702B To 16701 Expansion Frame To 16701 Expansion Frame Target Control Target Control Keyboard Keyboard Mouse...

Страница 13: ...To 16701 Expansion Frame To 16701 Expansion Frame Target Control Target Control Keyboard Mouse 13 16allp13 Your printer 16700B or 16702B Printers for 16700B 16702B...

Страница 14: ...14 16allp14 Printer Setup Done Done Your printer Refer to the online help for networked printers Network Printer Setup in Printers for 16700B 16702B...

Страница 15: ...Drive Cable To 16701 Expansion Frame To 16701 Expansion Frame Target Control Target Control Keyboard Mouse Set the External Disk drive address to 3 or 4 Removable Drive External Disk Drive for 16700A...

Страница 16: ...Busy 16700A B or 16702A B Data Drive Done Done 1 External Disk Drive for 16700A 16700B 16702A 16702B as External Data Drive Option 008 To power up the system To power down the system System power 1 1...

Страница 17: ...ernal Disk Drive Cable To 16701 Expansion Frame To 16701 Expansion Frame Target Control Target Control Keyboard Mouse Set the External Disk Drive address to 6 Removable Drive External Disk Drive for 1...

Страница 18: ...nitor Power If applicable 2 Disk Drive Power System power 3 16700A Logic Analysis System Power Busy 16700B or 16702B 1 To power up the system To power down the system System power 1 16700A Logic Analy...

Страница 19: ...et Control Target Control Keyboard Mouse A CD ROM drive and an external hard drive s may be connected to the SCSI II port at the same time CD ROM Drive 1 68 pin 50 pin 50 pin 50 pin External Disk Driv...

Страница 20: ...Drive Power 2 When a system is shipped the factory installs the current operating system and ordered processor support packages and tools Done Done 1 External Disk Drive Power System power 4 External...

Страница 21: ...21 16allp17 When a system is shipped the factory installs the current operating system and ordered processor support packages and tools Software Installation for 16700B 16702B Measurement Modules...

Страница 22: ...22 16allp18 Install Additional Tools System Software Processor Support Select Media Type Software Installation for 16700B 16702B Measurement Modules AUXILIARY SW HP1670X PROC SUPPORT 167XXB...

Страница 23: ...e or packages The system will automatically reboot if it is required by the newly installed package Software Installation Done Done Software Installation for 16700B 16702B Measurement Modules Install...

Страница 24: ...pander frame Connect the power cable to the 16701A B Power up the 16700B or 16702B system To 16701 Expansion Frame To 16701 Expansion Frame Target Control Target Control Keyboard Mouse 16701A B Interc...

Страница 25: ...e Tip Assembly 01650 61608 Probe Tip Assembly 01650 61608 Probe Tip Probe Lead Logic Analyzer Pod The advantages of this are High input impedance See Equivalent Load Signal ground at the probe tip for...

Страница 26: ...be used You can use only this ground but signal quality for high speed signals will be poor For best results and when probing signals with rise and fall times of 1 ns or less ground each probe lead w...

Страница 27: ...arget board from 40 pins to 20 27 Target Connector Termination Adapter Target Connector Pinout Top View N C 2 4 D15 6 D13 8 D11 10 D9 12 D7 14 D5 16 D3 18 D1 20 GND 5V 1 3 CLK1 5 D14 7 D12 9 D10 11 D8...

Страница 28: ...4 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 5V 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2 Power GND 4 Signal GND 6 Signal GND 8 Signal GND 10 Signal GND 12 Signal GND 14 Signal GND 1...

Страница 29: ...er E5346A With Tip RC Network Tip RC Network Equivalent Load 10pF 250 ohm 370 ohm 90 9k ohm Signal Signal To Logic Analyzer Pod Ground Ground Includes logic analyzer 9pF 3pF 100k ohm Amp Mictor 38 Con...

Страница 30: ...8 Connector E5351A No Tip Network Suggested On Board RC Network 10pF 250 ohm 90 9k ohm Signal To High Density Adapter Cable Ground Must be terminated on board Equivalent Load 370 ohm Signal Ground Inc...

Страница 31: ...31 Measurement Modules 16allp26 Self Test for 16700B 16702B all Measurement Modules Choose a module and select the desired test...

Страница 32: ...32 16allp28 Select an instrument Specifications Characteristics for 16700B 16702B all Measurement Modules Select on the Main Menu...

Страница 33: ...quired follow the steps in this book to setup the instrument and CD ROM drive Insert the CD ROM containing the instrument operating software into the CD ROM drive Allow a couple of moments for the med...

Страница 34: ...must be installed manually once the operating system has been reinstalled Reinstalling the Operating System Done Done 6 After about 30 seconds you will see the message WARNING The configuration inform...

Страница 35: ...lexible disk or a mounted directory you create a backup file that can be used to quickly setup systems or restore current system settings after the Disaster Recovery procedure My Backup Disk 35 disas...

Страница 36: ...or was not initially saved to the file the selection will be greyed out in the interface Also if no file extension is added a set extension is automatically added for you 36 disasbk 1 My Backup Disk 5...

Страница 37: ...es must have its port open and the last frame in the series must have its port open INPUT OUTPUT Agilent 16700B and 16702B logic analysis systems ordered with the multi Agilent 16700 68717 multiframe...

Страница 38: ...38 16allp39 Multiframe for 16700B 16702B Install the Multiframe Modules into 16700B or 16702B frames CAUTION Be sure to unplug the power cable before beginning this procedure 2 1...

Страница 39: ...39 16allp40 Multiframe for 16700B 16702B Multiframe Module 3 4...

Страница 40: ...clean the cabinet of the instrument or the front of the modules Harsh soap might damage the water based paint Do not immerse the instrument or modules in water CAUTION Instrument Cabinet and Module Fr...

Страница 41: ...Measurement Modules 16533 34A 16720A 16557D 16522A 16715 16710 11 12A 16 17 18 19A 16517 18A 16517 18A 16522A 16533 34A 16557D 16710 11 12A 16715 16 17 18 19A 16720A 16750 51 52A for 16700A B 16702A B...

Страница 42: ...apply pressure to the center of the module or filler panel while tightening the thumb screws Use filler panels in empty slots for proper cooling Some require calibration if they are moved to a differ...

Страница 43: ...43 16517p08 2 Card Module OR Expander Master 16518A 16517A 2 Connector Cable MASTER EXPANDER Expander Master 2 Connector Cable 16518A 16517A EXPANDER MASTER 16517A 18A...

Страница 44: ...44 16517p07 3 Card Module 3 Connector Cable Expander Expander Master 16518A 16518A 16517A EXPANDER EXPANDER MASTER 16517A 18A...

Страница 45: ...45 16517p06 3 Card Module 16517A 16518A 16518A 2 Connector Cable 2 Connector Cable Expander Expander Master EXPANDER MASTER EXPANDER 16517A 18A...

Страница 46: ...46 16517p05 3 Card Module 3 Connector Cable Expander Expander Master 16518A 16518A 16517A MASTER EXPANDER EXPANDER 16517A 18A...

Страница 47: ...47 16517p04 4 Card Module 3 Connector Cable 2 Connector Cable Expander Expander Expander Master 16518A 16518A 16518A 16517A EXPANDER EXPANDER MASTER EXPANDER 16517A 18A...

Страница 48: ...48 16517p03 4 Card Module 3 Connector Cable 2 Connector Cable Expander Expander Expander Master 16518A 16518A 16518A 16517A EXPANDER MASTER EXPANDER EXPANDER 16517A 18A...

Страница 49: ...9 16517p02 5 Card Module 3 Connector Cables Need 2 Expander Expander Expander Expander Master 16518A 16518A 16518A 16518A 16517A EXPANDER EXPANDER MASTER EXPANDER EXPANDER 16517 18 Done Done 16517A 18...

Страница 50: ...on can be installed in any available slot Be sure the frame is unplugged before removing or installing modules The following pages will show you how to connect the to configure two three four and five...

Страница 51: ...Card Module Expander J12 J11 J10 J9 J7 J8 Master J12 J11 J10 J9 J7 J8 Expander J12 J11 J10 J9 J7 J8 Master J12 J11 J10 J9 J7 J8 Expander J12 J11 J10 J9 J7 J8 MASTER EXPANDER EXPANDER MASTER EXPANDER 2...

Страница 52: ...Expander J12 J11 J10 J9 J7 J8 EXPANDER MASTER EXPANDER EXPANDER 2x10 Cable Carefully slide the four cards half way into the mainframe slots Cable the bottom Expander to the Master Card first Cable th...

Страница 53: ...7 J8 Expander J12 J11 J10 J9 J7 J8 Carefully slide the five cards half way into the mainframe slots Cable the bottom two Expanders to the Master first Cable the upper two Expanders to the Master Gentl...

Страница 54: ...ot be saved when the system is shut down The system will default to the previous settings The new calibration settings would be effective for the current active session only Remove the module from the...

Страница 55: ...wer ON 5 16600A Series 16700A B 16702A B Reinstall the 16533A 34A module into the mainframe and reconnect the power cable Monitor power ON If applicable 3 4 Keyboard Mouse RS 232 Monitor Parallel Prin...

Страница 56: ...6 16533p03 Connect the BNC Tee and the equal length BNC cables to the module 7 For more accurate calibration allow the system 30 minutes to warm up 6 15 15 30 0 Single Card Module 16533 34A Calibratio...

Страница 57: ...57 16533p04 Single Card Module 16533 34A Calibration RUN Select 16534A...

Страница 58: ...58 16533p05 Single Card Module 16533 34A Calibration...

Страница 59: ...59 16533p06 Connect the BNC Tee adapter and the equal length BNC cables to the module Single Card Module 16533 34A Calibration...

Страница 60: ...emember to set the PROTECTED UNPROTECTED switch back to PROTECTED If you just calibrated this card as one of a multi card set you must leave the PROTECTED UNPROTECTED switch in the UNPROTECTED positio...

Страница 61: ...See previous pages The following example is of a two board arrangement Up to four cards may be configured in a 16700A 16700B 16702A or 16702B mainframe 16533 34A Single Card Module Connect the module...

Страница 62: ...Connect the equal length BNC calibration between channel 1 AC DC cal and channel 1 of the second card Channel 1 of the third card next time etc up to four cards Chan 1 Chan 1 Chan 1 Chan 1 Chan 2 Chan...

Страница 63: ...dditional card in your multi card module Select the appropriate combination for each additional card Remember to set the switch back to PROTECTED UNPROTECTED PROTECTED Multi Module Calibration Done Do...

Страница 64: ...ter J3 J9 J10 J6 J8 J5 J7 J4 64 Single Card Module 16557p03 When ordered as a single card the 16557D is shipped with the factory configured as a single card module 2x10 cable 2x10 Cable 2x10 Cable 165...

Страница 65: ...x10 Cables Expander Master Master J3 J9 J10 Expander J6 J6 J8 J8 J5 J5 J7 J7 J4 J4 J3 J9 J10 MASTER EXPANDER Find the required two connector and connect the cables as shown 2x25 cables Connect the on...

Страница 66: ...J7 J7 J7 J4 J4 J4 J3 J3 J9 J9 J10 J10 2x25 Cables Need 2 2x10 Cables Expander Expander Master EXPANDER MASTER EXPANDER Find the required three connector and connect the cables as shown 2x25 cables Co...

Страница 67: ...J5 J5 J7 J7 J7 J7 J4 J4 J4 J4 J3 J3 J3 J9 J9 J9 J10 J10 J10 Expander Expander Expander Master 2x25 Cables Need 2 EXPANDER MASTER EXPANDER EXPANDER 2x10 Cables Find the required four connector and con...

Страница 68: ...pander Expander J6 J6 J6 J6 J6 J8 J8 J8 J8 J8 J5 J5 J5 J5 J5 J7 J7 J7 J7 J7 J4 J4 J4 J4 J4 J3 J3 J3 J3 J9 J9 J9 J9 J10 J10 J10 J10 Find the required five connector and connect the cables as shown 2x25...

Страница 69: ...le The 16700A 16700B 16702A and 16702B require Rev A 01 20 00 or higher See the Software Installation chapter in the book Select 1660X 70XA A single 16710A 16711A and 16712A will have the cable connec...

Страница 70: ...70 16710P03 Expander Master J7 J5 J5 J6 J6 J7 J8 J8 J9 J9 Multi Card Module 2x25 Cable 2x40 Cable 2x40 Cable 2x25 Cable 16710 11 12A...

Страница 71: ...71 16710P04 Other modules or filler panels J5 J5 J6 J7 J9 J6 J7 J9 J8 J8 Multi Card Module Multi Card Module Done Done 16710 11 12A...

Страница 72: ...50 00 or higher require software Rev A 02 00 00 or higher 16715 16 17A s The 16718 19A s The 16750 51 52A See the Software Installation chapter in this book A single 16715 16 17 18 19A or 16750 51 52A...

Страница 73: ...n the accessory pouch and find two of the required Connect 2x40 cables the on the modules as shown 2x40 cables MASTER EXPANDER 2x40 Cable 2x40 Cable 2x40 Cable 2x10 Cable Master J3 Expander J6 J6 J8 J...

Страница 74: ...J4 J4 J4 J3 J3 2x10 Cable 2x10 Cable 2x40 Cable 2x40 Cable Master J3 Expander Expander J6 J6 J6 J8 J8 J8 J5 J5 J5 J7 J7 J7 J4 J4 J4 J3 J3 Connect the of the Expanders to the Master Find the in the acc...

Страница 75: ...J4 J4 J3 J3 J3 2x10 Cables 2x10 Cable 2x40 Cable 2x40 Cable 2x40 Cable Master J3 Expander Expander Expander J6 J6 J6 J6 J8 J8 J8 J8 J5 J5 J5 J5 J7 J7 J7 J7 J4 J4 J4 J4 J3 J3 J3 Connect the of the Expa...

Страница 76: ...Cable Master J3 Expander Expander Expander Expander J6 J6 J6 J6 J6 J8 J8 J8 J8 J8 J5 J5 J5 J5 J5 J7 J7 J7 J7 J7 J4 J4 J4 J4 J4 J3 J3 J3 J3 2x10 Cables 2x10 Cables 2x40 Cable 2x40 Cable 2x40 Cable 2x40...

Страница 77: ...available slot Be sure the frame is unplugged before removing or installing modules The 16720A requires software Rev A 02 00 00 or higher The following pages will show you how to connect the to confi...

Страница 78: ...rd Module Expander J13 J12 J11 J10 J9 J8 Master Expander Master Expander MASTER EXPANDER EXPANDER MASTER EXPANDER 2x10 Cable 2x10 Cable 16720A J13 J12 J11 J10 J9 J8 J13 J12 J11 J10 J9 J8 J13 J12 J11 J...

Страница 79: ...slide the four cards half way into the mainframe slots Cable the bottom Expander to the Master Card first Cable the upper two Expanders to the Master Card Gently slide the cabled assembly fully into t...

Страница 80: ...he bottom two Expanders to the Master first Cable the upper two Expanders to the Master Gently slide the cabled assembly fully into the frame and tighten EXPANDER EXPANDER MASTER EXPANDER EXPANDER 2x1...

Страница 81: ...16702B All options based on the above Manufacturer s Name Manufacturer s Address Additional Information Product Name Model Number s Product Options s declares that the product The product herewith com...

Страница 82: ...l level appliances portable equipment etc with smaller transient overvoltages than installation category Indoor use only Altitude up to 3000 m 10 000 ft I II II III Instrument 0 degrees C to 50 degree...

Страница 83: ...16518A 16522A 16533A 16534A 16557D 16710A 16711A 16712A 16715A 16716A 16717A 16718A 16719A All Manufacturer s Name Manufacturer s Address Supplementary Information Product Name Model Number s Product...

Страница 84: ...ategory overvoltage category Local level appliances portable equipment etc with smaller transient overvoltages than installation category Indoor use only Altitude up to 3000 m 10 000 ft I II II III In...

Страница 85: ...1A and 16752A All options based on the above Manufacturer s Name Manufacturer s Address Additional Information Product Name Model Number s Product Options s declares that the product The product herew...

Страница 86: ...ategory overvoltage category Local level appliances portable equipment etc with smaller transient overvoltages than installation category Indoor use only Altitude up to 3000 m 10 000 ft I II II III In...

Страница 87: ...ltage and specified type normal blow time delay etc should be used Do not use repaired fuses or short circuited fuseholders To do so could cause a shock or fire hazard Service instructions are for tra...

Страница 88: ...e products that prove to be defective For warranty service or repair this product must be returned to a service facility designated by For products returned to for warranty service the Buyer shall pre...

Отзывы: