Contents

Содержание 16048A

Страница 1: ...Agilent 16048A Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan Ltd Agilent PN 16048 90001 March 2000 Printed in Japan ...

Страница 2: ... reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated 1990 First Edition part number 16048 90000 November 1998 Second Edition part number 16048 90001 August 1999 Third Edition part number 16048 90001 March 2000 Fourth Edition part number 16048 90001 Safety Summary The following general safety precautions must be observed during al...

Страница 3: ... resuscitation is present DO NOT Substitute Parts Or Modify Instrument Because of the danger of introducing additional hazards do not install substitute parts or perform unauthorized modifications to the instrument Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained Dangerous Procedure Warnings Warnings such ...

Страница 4: ...rants that its software and firmware designated by Agilent Technologies for use with an instrument will execute its programming instruction when property installed on that instrument Agilent Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free Limitation of Warranty The foregoing warranty shall not apply to defects resulting...

Страница 5: ...ymbol when it is necessary for the user to refer to the instrument manual WARNING This warning sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in injury or death to personnel CAUTION This Caution sign denotes a hazard It calls attention to a procedure practice condition or the like which if not corre...

Страница 6: ...6 ...

Страница 7: ...Contents 7 1 Operation Product Description 10 Specifications 11 Typical Characteristics 12 Compensation for Fixture Residual Impedance Error 13 2 Service Maintenance 16 ...

Страница 8: ...8 Contents ...

Страница 9: ...8A Test Leads The 16048A is shown pictorially in Figure 1 1 its physical dimensions are given in Table 1 1 and typical characteristics related to offset error are given in Table 1 2 To order additional copies of this operating note use the part number listed on the rear cover ...

Страница 10: ...nt 4 terminal pair type fixture which is equipped with four BNC m terminated coaxial test leads These test leads are used to attach user fabricated test fixtures DC bias levels of up to 40V can be applied to the 16048A Cable length is 1 meter The 16048A is shown in Figure 1 1 Figure 1 1 Product Overview ...

Страница 11: ... with 4 terminal pair LCR Meters and Impedance Analyzers Connector Type BNC male Cable Length Approximately 1m Maximum Voltage 40V peak max AC DC Weight 315 g Safety Standards EN61010 1 1993 A2 1995 IEC61010 1 1990 A1 1992 A2 1995 CSA C22 2 No 1010 1 1992 INSTALLATION CATEGORY I POLLUTION DEGREE 2 INDOOR USE ...

Страница 12: ...stics NOTE f is the measurement frequency in megahertz The incremental errors calculated from the equation in the table for measurements at frequencies above 1 MHz are additive Figure 1 2 Incremental error at freq 1 MHz Parameter reading error Offset value for D 5 f 10 è ø æ ö 2 0 02 f 10 è ø æ ö 2 ...

Страница 13: ...6048A has inherent stray capacitance residual inductance and residual resistance that affect the accuracy of measured values To compensate for or negate these residuals to minimize measurement error the instrument s Open Short compensation procedure should be performed The procedure is given in the instrument s operating manual ...

Страница 14: ...14 Chapter1 Operation Compensation for Fixture Residual Impedance Error ...

Страница 15: ...15 2 Service ...

Страница 16: ...ipally of cleaning contacts and replacing worn or damaged parts Take special care when cleaning contacts To order parts use the Agilent Technologies part numbers listed in Table 2 1 If a faulty part is located in an assembly that cannot be disassembled order the next higher assembly or return the whole device to the nearest Agilent Technologies Sales Service Office for repair or replacement ...

Страница 17: ...Chapter 2 17 Service Maintenance Figure 2 1 Parts Identification ...

Страница 18: ...TOR BNC 10 2 CONNECTOR BNC 11 2200 0103 1 SCREW 12 2190 0206 1 WASHER 13 16047 40000 1 STOPPER 15 16048 04000 1 COVER TOP 16 1400 0719 2 TIE RAP 17 1 GROMMET 18 1 CABLE 19 1 BUSHING 21 2360 0115 1 SCREW 22 3050 0010 1 WASHER 23 16021 50021 1 CABLE CRAMP 24 16021 50022 1 CABLE CRAMP 25 4 BOOT BNC 26 4 SLEEVE 27 4 SLEEVE 28 4 INSULATOR 29 1250 0089 4 CONTACT 30 1250 0052 4 CONNECTOR BNC 16048 60010a...

Страница 19: ...0 0118 4 CONNECTOR BNC FEMALE 32 2360 0115 2 SCREW 1 thru 30 33 16032 10021 1 PLATE 34 2190 0016 4 WASHER 35 2950 0001 4 NUT 36 16032 10022 1 PLATE 37 16032 60001 1 BNC BRACKET 31thru36 a Agilent internal only part number Reference Agilent Part No Qty Description Note ...

Страница 20: ...20 Chapter2 Service Maintenance ...

Страница 21: ...rope Agilent Technologies Test Measurement European Marketing Organization P O Box 999 1180 AZ Amstelveen The Netherlands tel 31 20 547 9999 Japan Agilent Technologies Japan Ltd Call Center 9 1 Takakura Cho Hachioji Shi Tokyo 192 8510 Japan tel 81 426 56 7832 fax 81 426 56 7840 Latin America Agilent Technologies Latin American Region Headquarters 5200 Blue Lagoon Drive Suite 950 Miami Florida 3312...