DANGER/ DANGER 

Dangerous Voltage! Tension électrique dangereuse! 

If the covers are attached correctly, no contact with dangerous tension 
is possible. Never remove the cover!  

Lorsque les capots sont fixés correctement, n’y a pas de contact avec 
tension dangereuse est possible.N'ouvrez jamais le capot de 
l’instrument! 

It is not allowed to insert objects into the housing. 

Ne jamais introduire d'objets non prévus à cet effet dans les 
ouvertures du boîtier 

Module is partially energized when switched off, as long as power cord 
is plugged in. 

L'alimentation continue à utiliser un peu d'électricité, même si 
l'interrupteur du panneau avant est en position d'arrêt (OFF). 



Repair work at the module can lead to personal injuries, e.g. shock 

hazard, when the module cover is opened and the instrument is 
connected to power. 

Les travaux de réparation sur le module peuvent entraîner des 
blessures, par ex. des électrocutions, lorsque le capot du module est 
ouvert et que l'instrument est branché au secteur. 



Provide sufficient space next to the power socket of the instrument 

to allow the cable to be unplugged. 

Prévoyez un espace suffisamment important à proximité de la prise 
d'alimentation pour que le câble puisse être débranché. 



Unplug the power cord before opening the module. 

Débranchez le câble d’alimentation de l’instrument avant d’ouvrir le 
capot de l’instrument. 

 

WARNING/ AVERTISSEMENT 

Sharp Metal Edges! Arêtes métalliques tranchantes! 

Sharp-edged parts of the equipment may cause injuries. 

Les composants de l'instrument dotées d'arêtes tranchantes peuvent 
occasionner des blessures. 



In order to prevent personal injury, be careful when getting in 

contact with sharp metal areas. 

Afin d'éviter de vous blesser, prenez garde aux arêtes métalliques 
tranchantes. 

Содержание 1220 Infinity II LC Series

Страница 1: ...Scientific Instruments Manufacturer GmbH D Oberhausen 49 0 208 94 10 78 0 www sim gmbh de User Manual SIM Sample Cooler for Agilent 1220 Infinity II LC System ...

Страница 2: ...GmbH shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Copyright 2018 SIM GmbH Printed in Germany All rights reserved NOTE Read this instruction carefully prior...

Страница 3: ...or OpenLAB CDS 2 x 9 3 SITE REQUIREMENTS 9 4 MODE OF OPERATION 10 5 INITIAL OPERATION 11 5 1 Connections 11 5 2 Software Installation 12 5 3 Set Up and configuration for OpenLAB ChemStation EZChrom OPT021 022 024 12 5 3 1 Software settings for OPT021 022 024 OpenLAB CDS ChemStation EZChrom 2 x 19 5 3 2 Installation of the Standalone Software OPT023 20 5 3 3 Software settings for OPT023 Standalone ...

Страница 4: ...rence to the User Manual of the Agilent 1220 Infinity II LC System G4280 90016 3 Prevent errors and protect persons against injuries and the device against damage 4 Make sure that the ventilation slots of the module are not covered and sufficient ventilation is provided additional 10 cm 3 9 in space to the side and in the rear 5 Periodically remove dust from the ventilation slots to prevent overhe...

Страница 5: ...is danger is not avoided Dommages matériels si ce danger n est pas évité 1 3 General Safety Instructions Informations générales de sécurité The following safety instructions are essential and have to be observed in all operating modes including maintenance and repair work of the module Failure to observe the precautions and warnings in the manual result in the violation of development production a...

Страница 6: ...l injuries e g shock hazard when the module cover is opened and the instrument is connected to power Les travaux de réparation sur le module peuvent entraîner des blessures par ex des électrocutions lorsque le capot du module est ouvert et que l instrument est branché au secteur Provide sufficient space next to the power socket of the instrument to allow the cable to be unplugged Prévoyez un espac...

Страница 7: ...lorsque la pince se trouve sous l aiguille CAUTION ATTENTION Liquids at in the module Liquides dans ce module Liquids at in the module will damage the system electronics Les liquids présents dans le module endommageront l électronique du système Make sure that no liquid enters the module because this can result in electrical shock and the destruction of the device La présence d un liquide dans le ...

Страница 8: ... cooling plate and cooling hoses as well as electrical connections 2 edge protection and fixing screw 3 syringe with threaded connection 4 for refilling the coolant manual not shown 2 2 OPT021 Driver for OpenLABCDS ChemStation software LC 1220 10 21 2 LAN cables 0 2 and 2m LC 1220 10 75 2 3 OPT022 Driver for OpenLAB CDS EZChrom software LC 1220 10 22 2 LAN cables 0 2 and 2m LC 1220 10 75 2 4 OPT02...

Страница 9: ...Never use cables other than the ones supplied by SIM and Agilent Technologies to ensure proper functionality and compliance with safety or EMS regulations N utilisez jamais de câble d alimentation autre que le modèle SIM et Agilent Technologies destiné à votre pays NOTE In case of emergency it must be possible to disconnect the instrument from the power line any time Make sure that there is easy a...

Страница 10: ...e cooling module for the sample tray of the Agilent 1220 Infinity II LC System is firmly mounted on the LC It is designed to temper the sample tray from 5 C to 40 C The module is controlled by the delivered SIM software possible options driver for OpenLAB CDS ChemStation EZChrom 2 x or a standalone version The original sample tray is modified by a metal plate beneath the sample tray This plate is ...

Страница 11: ... module with the LC system by using the APG remote cable Fig 2 Connections Tab 1 Connections Connection Action LAN connect the cooling module through LAN with the LC system upper LAN port as well as with the PC or laboratory network lower LAN port USB Port currently not in function developed for future use APG Remote combined with the stand alone software this port is used for connection of coolin...

Страница 12: ...80 90016 chapter 3 2 Then install the software file setup_SIMPeltierDriver_Vxxx exe for using OpenLAB CDS ChemStation EZChrom 2 x see chapter 5 3 1 or setup_SIM_LC1220_Vxxx exe for using stand alone version see chapter 5 3 2 on the PC The cooling module is set to a default fixed IP address 192 168 254 99 Class C network with a subnet mask of 255 255 255 0 You can communicate with the device as lon...

Страница 13: ...Scientific Instruments Manufacturer GmbH D Oberhausen 49 0 208 94 10 78 0 www sim gmbh de User Manual SIM Sample Cooler_06 2018 13 ...

Страница 14: ...bH D Oberhausen 49 0 208 94 10 78 0 www sim gmbh de 14 User Manual SIM Sample Cooler_06 2018 2 When the installation is finished start your Chromatographic data system and note the differences between ChemStation edition and EZChrom edition ...

Страница 15: ... Sample Cooler and add this module using the Arrow button With a click on the button Configure the device specific configuration dialogue is opened Configuration of the Sample Cooler EZChrom and 2 x edition 4 At the instrument configuration screen select the SIM Sample Cooler and add this module using the Arrow button Double click the entry on the right side or right click and choose Open to enter...

Страница 16: ...f PC and Sample Cooler 6 If the network settings are correct the IP address is obtained automatically and the serial number is displayed Complete the installation of the driver with a click on the OK button in the window with the serial number and then the OK button in the main window If an error message is displayed check the connection of PC and Sample Cooler as well as the power supply to corre...

Страница 17: ... or former changes have to be reverted 8 Click on TCP IP settings so that the dialogue on the left will be opened All the devices which are physically connected to the instrument server work station PC are shown here If no device appears click Discover to retry the search for devices and check the cable connection Choose the device from the list and click either Enable DHCP to let the device retri...

Страница 18: ...get ready Switch Off after Sequence cooling of the samples automatically ends when the sequence is finished Cooler Controlled by method you can specify methods in OpenLAB CDS which control the temperature setpoint the readiness feature and the temperature tolerance If the box is unchecked the cooler can only be switched on and off using the status dashboard the temperature setpoint can only be cha...

Страница 19: ...IM Tray Cooler There are little differences between EZChrom 2 x and ChemStation EZChrom 2 x after a right click in the window SIM Tray Cooler select Download Settings from the drop down menu ChemStation automatically transmits these changes when you close the Method window with OK or Apply All necessary information about this module and its settings are obtained by clicking on the help button see ...

Страница 20: ...stall the software file SETUP_SIM_LC1220_VXXX EXE and follow the instructions in the Setup Wizzard similar procedure described in chapter 5 3 At the end of the installation you see the following window Fig 4 Installation standalone software 2 Request the IP address by clicking Discover 3 Enter the address marked in the red circle above into the field Network in the Communication Settings ...

Страница 21: ...ample Cooler_06 2018 21 Or Assign a Fixed IP Address The cooling module is set to a default fixed IP address 192 168 254 99 Class C network with a subnet mask of 255 255 255 0 Use File Change IP Address to assign a new fixed IP address In this case no dynamic IP address is requested via DHCP Fig 5 IP address ...

Страница 22: ...irm the value with SET Further buttons Tab 2 Display Display Definition Status bar Left temporary information about connection to cooling module Right status message of the cooling module Discover Find the related IP address see log window found new device at IP 10 43 43 220 red marking in Fig 6 Connect Connect the software and cooling module Config Select the Ready conditions for the APG Remote p...

Страница 23: ...e to the cooling module OFF Switch off only the Peltier element of the cooling module the complete cooling module is switched on off with the switch at the rear of the module see Fig 2 Current temperature Shows the actual temperature at the cooling plate Config Settings for APG Interface Select the Ready conditions by clicking on the Config button Fig 7 Settings for APG interface ...

Страница 24: ...ter level at the viewing window see Fig 2 It should be within the min max marking when the pump is not working If necessary please contact a service engineer to refill distilled water 2 Please check the water level also during operation and a longer break as well as before every restart 6 4 Setting of Parameters for the Sample Tray Cooling NOTE Even if you use an OpenLAB driver keep in mind the eq...

Страница 25: ... Débranchez le câble d alimentation de l instrument avant d ouvrir le capot de l instrument WARNING AVERTISSEMENT Risk of personal injury through sharp metal edges Des blessures grave par les composants de l instrument dotées Sharp edged parts of the equipment may cause injuries Les composants de l instrument dotées d arêtes tranchantes peuvent occasionner des blessures To prevent personal injury ...

Страница 26: ...ircuit d écoulement Clean the module case with a soft cloth slightly dampened with water or a solution of water and a mild detergent 7 2 Water level DANGER DANGER Risk of explosion or fire Risque d explosion ou d incendie Use of explosive or inflammable liquids can cause an explosion or fire L utilisation de liquides explosifs ou inflammables peut provoquer une explosion ou un incendie Never fill ...

Страница 27: ...he water level at the viewing window red arrow in Fig 8 when the pump is not working In order to improve visibility at the viewing window light the water tank with a flashlight shining through the ventilation slots below 2 If the level is below the min marking please contact a service engineer for refilling distilled water Fig 8 Water level ...

Страница 28: ...warning level Temperature display gets red and Peltier element is switched off in log data is displayed Peltier hot side is at error level disabled Peltier no cooling water see viewing window fan is covered or damaged ambient temperature is too high contact service engineer check the distance to other devices the wall minimum distance 10 cm clean the fan grill or contact the service engineer make ...

Страница 29: ...ambient 5 C to 40 C Non operating temperature ambient 40 70 C Humidity max 95 at 40 C non condensing Interfaces APG Remote LAN USB for future use Cooling Liquid distilled water see also annotations in chapter 7 2 Operating altitude 2000 m Safety standards CSA installation category II pollution degree 2 for indoor use only Tab 5 Performance specifications Type Specification Temperature range Settab...

Отзывы: