Programming
Common
Commands
*ESE
(Event
Status
Enable)
The
*ESE
command
sets
the
bits
in
the
Standard
Event
Status
Enable
Register
.
The
Standard
Event
Status
Enable
Register
contains
a
mask
value
for
the
bits
to
be
enabled
in
the
Standard
Event
Status
Register
.
A
one
in
the
Standard
Event
Status
Enable
Register
enables
the
corresponding
bit
in
the
Standard
Event
Status
Register
.
A
zero
disables
the
bit.
Refer
to
T
able
4-1
for
information
about
the
Standard
Event
Status
Enable
Register
bits
,
bit
weights
,
and
what
each
bit
masks
.
The
*ESE
query
returns
the
current
contents
of
the
register
.
Command
Syntax:
*ESE
< mask >
Where:
< mask >
::=
0
to
255
Example:
1
OUTPUT
720;\*ESE
64"
Query
Syntax:
*ESE?
Returned
F
ormat:
< mask >< NL>
Where:
< mask >
::=
0
to
255
(integer{NR1
format)
Example:
OUTPUT
720;\*ESE?"
ENTER
720;Event
Event
1
In
this
example
,
the
*ESE
64
command
enables
URQ
(user
request)
bit
6
of
the
Standard
Event
Status
Enable
Register
.
Therefore
,
when
a
front
panel
ke
y
is
pressed,
the
ESB
(event
summary
bit)
in
the
Status
Byte
Register
is
also
set.
T
able
4-1.
Standard
Event
Status
Enable
Register
Enables
Standard
Event
Status
Enable
Register
(High{Enables
the
ERS
bit)
Bit
Weight
Enables
7
128
PON
-
P
ower
On
6
64
URQ
-
User
Request
5
32
CME
-
Command
Error
4
16
EXE
-
Execution
Error
3
8
DDE
-
Device
Dependent
Error
2
4
QYE
-
Query
Error
1
2
TRG
-
T
rigger
Query
0
1
OPC
-
Operation
Complete
4-20
Содержание 11896A
Страница 2: ...User Programming and Service Guide Agilent 11896A Polarization Controller ...
Страница 17: ...Contents ...
Страница 18: ...1 General Information ...
Страница 30: ...General Information Speci cations and Characteristics 1 13 ...
Страница 33: ...General Information Electrostatic Discharge Information Figure 1 8 Example of a static safe work station 1 16 ...
Страница 35: ...General Information ...
Страница 36: ...2 Installation and Preparation for Use ...
Страница 54: ...3 Using the Agilent 11896A Polarization Controller ...
Страница 59: ...Rear Panel Features The Agilent 11896A rear panel 1 Power input 2 GPIB connector 3 6 ...
Страница 65: ...Using the Agilent 11896A Polarization Controller Using the Agilent 11896A ...
Страница 66: ...4 Programming ...
Страница 100: ...5 Veri cation and Service Information ...
Страница 121: ...Veri cation and Service Information ...
Страница 122: ...A Choosing the Scan Rate and Measurement Time ...
Страница 126: ...B Measurement Considerations ...
Страница 131: ...Measurement Considerations ...
Страница 132: ...Index ...