5.4. Shutdown
1. Close the gas shut off valve.
2. Allow heater flame to burn out. This drains all gas from supply.
3. Move the toggle switch to the OFF position.
5.5. Storage Instructions
If the heater is not to be used for an extended period of time:
1. Close the propane/natural gas valve at tank/hydrant.
2. Allow the heater unit to run until the flame burns out. This purges the gas out of the heater plumbing and
supply lines.
3. Turn the gas valve on the heater to OFF.
4. Turn off and unplug the heater.
5. Allow the fan to operate for at least 2 minutes to cool the heater down.
6. Shut off the fan.
7. Storage area:
•
Outside storage— cover the heater with a tarp or other protective cover.
•
Inside storage — ensure the heater is placed in a dry and safe location and away from anything that may
damage it.