1 - 3

Installation

Checking the scope of delivery ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

- 1 Telephone system
- 1 Set of securing material (3 dowels S6, 3

wood screws (cross head recess) 4 x 40)

- 11 connection terminals
- 1 ISDN connecting cable (IAE-IAE), 1.5 m
- 1 PC connecting cable
- 1 Instruction manual
- 1 Installation manual

- 4 Short-form operating instructions for

   system telephones

- 8 Short-form operating instructions for

   a/b and ISDN terminals

- 8 Remote control cards
- 1 Set of 3.5" diskettes with the programs:

   TK-Set, TK-Bill, TK-LCR, TK-Phone and
   TK-Timer.

Choosing a location ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

- The telephone system must only be in-

stalled in a dry room in which there are
no explosion hazards.
It must not be installed: in the proximity
of air conditioning systems. radiators, de-
vices that produce inadmissible interfer-
ence radiation, in locations that are sub-
ject to direct sunlight, in environments
containing excessive amounts of dust or
in locations where it may be splashed
with water or chemicals.

- Ambient temperature: 5°C to 40°C

- Humidity: max. 70% (no condensation)

- You must install the telephone system ver-

tically, with the connection side pointing
downwards, on a firm and flat surface.

- Minimum distance between the housing

and other limits above or below it: 50
mm.

- The distance between the telephone sys-

tem and the 230 V mains socket and the
IAE socket should not be more than 1 m
(mains lead approximately 1.2 m long).

- For configuration of the PBX AS 31 ST via

the serial PC / printer interface (RS 232C),
it must be possible to place a laptop or a
PC in the direct proximity of the tel-
ephone system.
The PBX AS 32, however, can be
configured by a PC with ISDN adapter via
the internal S0 bus.

Do not plug in the 230 V mains plug un-
til you have completed installation and
checked the wiring after closing the
housing.

Pay attention to the fact that the electri-
cal connection (shock-proof socket) for
the telephone system (and if applicable,
for additional devices) must have been
installed by an authorised electrician.
This will avoid any hazards for persons
and property.

A separate circuit is recommended for the
telephone system’s 230 V mains power sup-
ply.
Short-circuits caused by other domestic ap-
pliances will then not have any detrimental
influence on the telephone system.

Power consumption of the telephone sys-
tem: approximately 40 VA (full load).

230 V power supply ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

Содержание AS 31 ST

Страница 1: ...1 1 Installation Business Line AS 31 ST AS 32...

Страница 2: ...ust be electrically earthed Therefore connect the Euro PE contact plug of the power cable only to an expertly installed socket PE socket to prevent danger to persons and material Before connecting the...

Страница 3: ...ith the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits above or below it 50 mm The distance between the telephone sys tem and the 2...

Страница 4: ...Caution Disconnect power cord before remove M M Cover latching Cover Cover latching M Swiches S400 and S401 RS 232C Schnittstelle b7 a7 b8 a8 NF U TFE S0 Anschlu extern BE X16 externe MoH X15 X2 X3 X...

Страница 5: ...ting a connecting lead 1 Remove the telephone system s 230 V mains plug from the socket 2 Remove the Western plugs of all ex ternal ISDN basic accesses from the telephone system the network termina to...

Страница 6: ...1 b1 Internal S0 only AS 32 GND GND 1 2 3 4 5 6 TAE 6 F a b d a d b Systemtelephone Ports 1 to 4 Port 8 230 V Connections of TAE S400 S401 TS TS NF KT T0 T0 Port 3 GND Bell buttom Door hands free unit...

Страница 7: ...which must belong to one connecting line must be closed for the point to point connection Point to multipoint connection The point to multipoint connection may consist of an S0 bus Up to 12 ISDN socke...

Страница 8: ...ires to the La and Lb wires speech wires of the Vario ports You must not connect the Da and Db connections System telephones Connect system telephones by four wires to the Vario ports by connecting th...

Страница 9: ...an internal S0 port Telecommunications cable we recom mend the cable type I Y St Y 2 x 2 x 0 6 IAE or UAE connection sockets up to 12 sockets Terminators 100 Ohm load carrying ca pacity 0 25 watt 2 te...

Страница 10: ...ty 30 VDC 1 A or 123 VAC 0 5 A You can only activate the door opener from a terminal of the telephone system after connecting an external bell trans former For connection carry out the following op er...

Страница 11: ...ne system drawing 2 Set the volume of external music on hold on the audio device To set or check the vol Connecting external music on hold MoH ume call an internal user of the telephone system from an...

Страница 12: ...l ephone system s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as...

Страница 13: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Страница 14: ...ne number entered Number of calls 5 Don t disturb off for all terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal...

Страница 15: ...ection System telephones 4 wire plug in screw terminal a b terminals 2 wire plug in screw terminal Range System telephones 2 x 75 Ohm 0 6 mm twisted 1200 m a b terminals 2 x 50 Ohm 0 6 mm 800 m Dialli...

Страница 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Отзывы: