POWER UP SEQUENCE
After applying power to the unit, the front red LED will permanently illuminate for approximately 30 secs while
the operating system loads. The LED will then start flashing and either extinguish if the detector has been
previously set-up and revert to normal operation (illuminated if zone is in detect, not illuminated if zone is
empty), or the LED will continue to flash until the unit has been set-up and commissioned.
OPTO-COUPLER RATINGS FOR ALL
VOLTAGE VERSIONS
• Max current 60mA
• Max Voltage 100V
• Max on-state impedance 25 Ohms
ELECTRICAL INSTALLATION
The detector is powered using a 12-24V ac/dc (±20%) or 230Vac supply. For the
non mains units the power is applied to the detector using the multi-pin mating
connector.
The AGD641 Pedestrian Detector is provided with a Buccaneer Series PX0728/S 9
pole connector to enable direct connection to the traffic control system. The pin
outs of the connector and detector function are highlighted in the table below:
CONNECTIONS FOR 12V-24V ac/dc VERSIONS
CONNECTIONS FOR 230Vac VERSION
Installation and Commissioning
Pin
No.
Wire
Colour
Function
Power
Off
Power On-
No Detect
Power
On- Detect
1
RED
12-24V ac/dc
-
-
-
-
2
BLACK
0V ac/dc
-
-
-
-
3
GREEN
Earth/Ground
-
-
-
-
4
WHITE
Opto 1/2 Common -
-
-
-
5
YELLOW Opto 1 N/O
N/O
N/C
N/O
-
6
BLUE
Opto 1 N/C
N/C
N/O
N/C
Not for use on Puffins/Toucans
7
-
-
-
-
-
-
8
BROWN
Not Connected
-
-
-
-
9
VIOLET
Not Connected
-
-
-
-
Power supply
ratings
12Vac
24Vdc
24Vac
230Vac
Day time mode
-
-
170mA
17mA
Night time mode 300mA
140mA 200/255mA 24/30mA
Twin Cable 230Vac Supply Wiring (5m flying leads)
Cable
Wire Colour Function
Power Off Power On - No Detect Power On –Detect
Power
Brown
230Vac Live
-
-
-
Blue
230Vac Neutral
-
-
-
Signal
Red
Opto Common
-
-
-
Blue
Opto Contact
N/C
N/O
N/C
Green
Opto Contact
N/O
N/C
N/O