PRODUCT OVERVIEW IMAGE

PRODUCT VARIANTS 

 

 

 

 

 

PRODUCT OVERVIEW

The AGD641 Pedestrian Detector is an optical product that makes pedestrian crossings safer by delivering robust 
detection within a standard crossing zones. Multiple units easily integrate to cover larger wait areas.

It is a high-performance product that processes information on board with a new chip-set and sophisticated 
algorithms, automating decision-making to provide ultra-reliable detection.

The AGD641 Pedestrian Detector employs a 3D stereo vision optical system that detects moving and stationary targets 
over a 4 x 2m zone. It has an outstanding capability to detect people while rejecting shadows, litter, leaves and small 
objects such as birds walking through the zone.

It has Infra-red illumination for night time operation. 

Right Camera

12-24V ac/dc Version

230Vac Version

Right Camera

Left Camera

Left Camera

Low voltage 
supply and opto 
isolator detect 
outputs

Mains voltage 
supply and opto 
isolator detect 
outputs

Power-Up & 

Detect LED 

(red) and WiFi 

indicator (blue)

Introduction

Product No.

Description

641-500-021

Pedestrian Detector / 12-24V ac/dc / WiFi / Single Opto Output/1m lead / 1m bulkhead mating lead

641-503-021

Pedestrian Detector / 12-24V ac/dc  / WiFi / Single Opto Output / 5m flying lead

641-504-021

Pedestrian Detector / 12-24V ac/dc  / WiFi / Single Opto Output / 1m lead / 4m bulkhead mating lead

641-300-021

Pedestrian Detector / 230Vac / WiFi / Single Opto Output / 5m flying leads

Содержание 641-300-021

Страница 1: ...PRODUCT MANUAL AGD Systems Limited 2019 Doc Ref 641 PM ISS1 AGD641 PEDESTRIAN DETECTOR AGD641 PEDESTRIAN DETECTOR...

Страница 2: ...Connecting Wifi 7 Connecting device 7 Set up device using Wifi AGD Touch setup 8 Step 1 Name site 8 Step 2 Set zone 8 Step 3 Calibrate 9 Home page 9 Optional Parameters 10 TECHNICAL RESOURCE 11 Physi...

Страница 3: ...and stationary targets over a 4m x 2m zone The 641 maintains class leading shadow and unwanted object rejection PRODUCT AND TECHNOLOGY KEY FEATURES 4m x 2m zone adjacent to the detector saving on inf...

Страница 4: ...It has an outstanding capability to detect people while rejecting shadows litter leaves and small objects such as birds walking through the zone It has Infra red illumination for night time operation...

Страница 5: ...e Adjust the tilt angle to be 45 degrees from the horizontal 15 degrees to see a point 4m from base of pole when viewed from the detector Ensure that the detector is securely fixed and the mounting nu...

Страница 6: ...GD641 Pedestrian Detector is provided with a Buccaneer Series PX0728 S 9 pole connector to enable direct connection to the traffic control system The pin outs of the connector and detector function ar...

Страница 7: ...enotes the S N TBD is a renamable field used to name the pole location the 641 is installed on Click connect and input the default password Agd641 XXXXXX XXXX the X denotes the S N The LED on the fron...

Страница 8: ...n the zone is set click Next SET UP DEVICE USING AGD TOUCH SETUP When logged in to the device for the first time you click set up This is the AGD Touch Setup a three stage process that allows installe...

Страница 9: ...your selected zone actively detecting on the Home Page and helpfully if the detector has been previously setup you will come straight to the Home Page on connection The image you see on the screen wil...

Страница 10: ...ght Select this to allow the detector to illuminate the front RED led at night Hold Time sec This value denotes the amount of time the detection OPTO output is held AFTER a valid target leaves the are...

Страница 11: ...METERS The AGD641 operates with a high degree of accuracy when mounted inside normal parameters The diagram below shows a plan view of the expected coverage of the stereo cameras when the detector dev...

Страница 12: ...e unit 3 Is there sufficient current to run the unit identified by the red LED failing to flash or flashing only once during power up and the web page not starting correctly Refer to technical specifi...

Страница 13: ...o LED Indication Front LEDs for detect and WiFi connection Housing Material Black Polycarbonate Sealing IP55 Operating Temp 15 C to 60 C Configuration WiFi AGD Touch Setup Lux Level In built IR illumi...

Страница 14: ...7 2 HSAP 8 1 Polycarbonate Item Qty Material 9 1 Polycarbonate 10 4 Stainless Steel 11 7 Stainless Steel 12 1 Metal Nylon PVC 13 1 Printed Circuit board 14 6 Stainless Steel 15 2 Aluminium 16 2 Mixed...

Страница 15: ...uct must be correctly connected to the specified power supply All connections must be made whilst the power supply is off or suitably isolated Safety must take always take precedence and power must on...

Страница 16: ...16 Certification...

Страница 17: ...Notes...

Страница 18: ...Notes...

Страница 19: ...Notes...

Страница 20: ...iable for any loss or damage including without limitation indirect or consequential loss or damage or any loss or damage whatsoever arising from loss of data or profits arising out of or in connection...

Отзывы: