AGD 641-300-021 Скачать руководство пользователя страница 13

13

AGD 

641

PEDESTRIAN DETECTOR

AGD 

641

PEDESTRIAN DETECTOR

180mm

160mm

160mm

52.5mm

106mm

PRODUCT DIMENSIONS

Technical Specifications

SPECIFICATIONS

Description

Pedestrian Detector

Technology

AGD 3D HD Optical Stereo Vision

Detection Zone

4m x 2m

Mounting Height

3-4m (3.5m nominal)

Power Supply

12 - 24V ac/dc or 230Vac

Power

3.6W @ 12Vdc @ 300mA  /  6.9W @ 230Vac @ 30mA

 

6.1W @ 24Vac @ 255mA  /  3.4W @ 24Vdc @ 140mA

WiFi Frequency/Power

Frequency range (MHz): 2412-2472 
Highest EIRP power in the range (dBm): 19.7

Opto / Relay Current

60mA

Detect Output

Single Opto

LED Indication

Front LEDs for detect and WiFi connection

Housing Material

Black Polycarbonate

Sealing

IP55

Operating Temp

-15°C to +60°C

Configuration

WiFi AGD Touch-Setup

Lux Level

In built IR illuminator for low light/nightime

Dimensions

W 181mm x D 160mm x H 106mm

Weight

500g

Complies with

EMC: BS EN 50293: 2012, EN301 489-17, EN301 489-1 

Health & Safety: EN 60950-1, EN 60950-22, EN 50556, EN 62311 

Spectrum: EN 300 328. RoHS: EN 50581, TOPAS 2507A

Patent No.

GB 2448617

Owing to the Company’s policy of continuous improvement, AGD Systems Limited  

reserves the right to change their specification or design without notice.

RoHS

 COMPLIANT

Restriction on Hazardous 

Substances

Registration 

Evaluation 

Authorisation 

and Restriction of 

Chemicals

Содержание 641-300-021

Страница 1: ...PRODUCT MANUAL AGD Systems Limited 2019 Doc Ref 641 PM ISS1 AGD641 PEDESTRIAN DETECTOR AGD641 PEDESTRIAN DETECTOR...

Страница 2: ...Connecting Wifi 7 Connecting device 7 Set up device using Wifi AGD Touch setup 8 Step 1 Name site 8 Step 2 Set zone 8 Step 3 Calibrate 9 Home page 9 Optional Parameters 10 TECHNICAL RESOURCE 11 Physi...

Страница 3: ...and stationary targets over a 4m x 2m zone The 641 maintains class leading shadow and unwanted object rejection PRODUCT AND TECHNOLOGY KEY FEATURES 4m x 2m zone adjacent to the detector saving on inf...

Страница 4: ...It has an outstanding capability to detect people while rejecting shadows litter leaves and small objects such as birds walking through the zone It has Infra red illumination for night time operation...

Страница 5: ...e Adjust the tilt angle to be 45 degrees from the horizontal 15 degrees to see a point 4m from base of pole when viewed from the detector Ensure that the detector is securely fixed and the mounting nu...

Страница 6: ...GD641 Pedestrian Detector is provided with a Buccaneer Series PX0728 S 9 pole connector to enable direct connection to the traffic control system The pin outs of the connector and detector function ar...

Страница 7: ...enotes the S N TBD is a renamable field used to name the pole location the 641 is installed on Click connect and input the default password Agd641 XXXXXX XXXX the X denotes the S N The LED on the fron...

Страница 8: ...n the zone is set click Next SET UP DEVICE USING AGD TOUCH SETUP When logged in to the device for the first time you click set up This is the AGD Touch Setup a three stage process that allows installe...

Страница 9: ...your selected zone actively detecting on the Home Page and helpfully if the detector has been previously setup you will come straight to the Home Page on connection The image you see on the screen wil...

Страница 10: ...ght Select this to allow the detector to illuminate the front RED led at night Hold Time sec This value denotes the amount of time the detection OPTO output is held AFTER a valid target leaves the are...

Страница 11: ...METERS The AGD641 operates with a high degree of accuracy when mounted inside normal parameters The diagram below shows a plan view of the expected coverage of the stereo cameras when the detector dev...

Страница 12: ...e unit 3 Is there sufficient current to run the unit identified by the red LED failing to flash or flashing only once during power up and the web page not starting correctly Refer to technical specifi...

Страница 13: ...o LED Indication Front LEDs for detect and WiFi connection Housing Material Black Polycarbonate Sealing IP55 Operating Temp 15 C to 60 C Configuration WiFi AGD Touch Setup Lux Level In built IR illumi...

Страница 14: ...7 2 HSAP 8 1 Polycarbonate Item Qty Material 9 1 Polycarbonate 10 4 Stainless Steel 11 7 Stainless Steel 12 1 Metal Nylon PVC 13 1 Printed Circuit board 14 6 Stainless Steel 15 2 Aluminium 16 2 Mixed...

Страница 15: ...uct must be correctly connected to the specified power supply All connections must be made whilst the power supply is off or suitably isolated Safety must take always take precedence and power must on...

Страница 16: ...16 Certification...

Страница 17: ...Notes...

Страница 18: ...Notes...

Страница 19: ...Notes...

Страница 20: ...iable for any loss or damage including without limitation indirect or consequential loss or damage or any loss or damage whatsoever arising from loss of data or profits arising out of or in connection...

Отзывы: