ELECTRICAL CONNECTION IS LOCATED AT THE TOP RIGHT HAND SIDE OF THE APPLIANCE, BEHIND SIDE PANEL.
DURING INSTALLATION REMOVE THE RIGHT HAND SIDE PANEL TO CONNECT ELECTRICAL SUPPLY.
Remove 3 screws securing side panel to gain access to mains terminal. See Fig. 4 for location of cover.
Remember that the mains electrical cable must be routed through the grommet at the rear right hand side of the cooker
near the top, before connecting to the mains terminal connection.
Refer to Fig. 3 for single phase wiring connection, or Fig 3A for three phase wiring connection to appliance.
Remember that an excess of cable length is required behind the cooker for the withdrawal of the cooker from between the
kitchen units etc.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
SINGLE PHASE CONNECTION
- The cooker requires a 45 amp power supply fitted in conjunction with a double pole
isolator with a minimum contact clearance of 3mm and be connected to the mains with a minimum 10mm
2
cable to comply
with the latest editions of the local and national wiring regulations.
THE ISOLATOR
MUST NOT
BE POSITIONED IMMEDIATELY ABOVE THE COOKER, BUT
MUST
BE SITED WITHIN 2
METRES OF THE APPLIANCE.
Replace the right hand side panel once electrical connection has been made and replace fixing screws.
NOTE:
Ensure that the insulation card covering the mains terminal is in place, between the side panel and mains terminal.
8
ELECTRICAL CONNECTION
Fig. 3
DESN 517106
SINGLE PHASE CONNECTION -
Minimum 10mm
2
cable and must comply with the latest editions of the local and
national wiring regulations.