42
23. Electrical connection - 160i
The isolator should not be positioned immediately above the
cooker, but must be fitted within 2 metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the
areas shown in
Fig. 23.1
and
Fig. 23.2
for cable routing
options.
For 2 or 3 phase installations an optional adaptor kit must be
obtained (Part No. AE4M280352).
Induction Hob
(100 - 4i, 160 - 5i)
An additional,
separate single phase power supply
is
required. 230V ~ 50Hz, 13amp fused three pin plug electrical
supply.
For the fan oven
(160i only)
An additional,
separate single phase power supply
is
required. 230V ~ 50Hz, 13amp fused three pin plug electrical
supply.
SECURE MAINS CABLE USING ‘P’ CLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.
450mm MA
X
2.5
me
tres
2.5 met
res
WORKTOP
WORKTOP
Cable point for 3m long 13A cable supplying induction hob.
Cable point for 3m long 32A cable supplying main cooker.
Cable point for 3m long 13A cable
supplying additional conventional
fan oven.
Fig. 23.1
Fig. 23.2
DESN 517652
AGDN 100248
n
WARNING: This appliance must be earthed.
n
This appliance is designed for the voltage stated on
the rating plate, which is situated behind the plinth
cover.
n
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified person to avoid a hazard.
For the Main cooker
A 1PH 13 amp 230V or 3PH 400V minimum 16A per phase
~ 50 Hz fused electrical supply is required adjacent to the
appliance. External wiring to the unit must be installed using
the mains cable provided, in accordance with the current
wiring regulations and any local regulations which apply.
If the cable is shortened, new ferrules must be fitted to the
stripped conductors.
The method of connection to the mains electricity supply
must facilitate complete electrical isolation of the appliance,
by a multi-pole switch, having a contact separation of at least
3 mm on all poles.
THE MAINS SUPPLY MUST BE WITHIN THE ZONES SHOWN. IF A RECESSED COOKER CONNECTION IS TO BE
USED BEHIND THE APPLIANCE WITHIN THE HATCHED AREA ALLOW A 5mm GAP AT REAR OF APPLIANCE.
Cable point for 3m long 13A cable supplying induction hob.
Cable point for 3m long 13A cable supplying main cooker.
Cable point for 3m long 13A cable
supplying additional conventional fan oven.
SECURE MAINS CABLE USING ‘P’ CLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.