![AGA MUCH WENLOCK CLASSIC Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/aga/much-wenlock-classic/much-wenlock-classic_installation-and-operating-instructions-manual_2865846005.webp)
Fig3
REAR FLUE EXIT
For rear flue outlet configuration push in flue con-
nector pipe (not supplied) into flue outlet socket at
the rear of the stove and cement into place using
approved fire cement ensuring that no cement
blocks the flue passageway.
Fig. 4
LOCATION
There are several conditions to be considered in
selecting a location for your stove.
a. Position in the area to be heated, central loca-
tions are usually best. If situated in an alcove, site
as far forward as possible to provide more heat to
the room. For non-combustible surfaces, allow a
minimum air gap to the rear, sides and top of
100mm for air to flow around the appliance.
b. Allowances for proper clearances to com-
bustibles.
INSTALLATION CLEARANCES
Clearance to combustible materials
From the front - 900mm
From the sides - 600mm
From the back - 700mm
From the flue pipe - 600mm
The connector may pass through walls or partitions
constructed of combustible materials provided the
connector is either listed for wall pass-through or is
routed through a device listed for a wall pass-
through and is installed in accordance with the con-
ditions of the listing. Any unexposed metal that is
used as part of a wall pass-through system is
exposed to flue gases shall be constructed of stain-
less steel or other equivalent material that will resist
corrosion, softening, or cracking from flue gas at
temperatures up to 982°C.
FLOOR PROTECTION
It is recommended that this appliance is installed on
a solid, level non-combustible hearth conforming to
current Building Regulations.
5