AGA MUCH WENLOCK CLASSIC Скачать руководство пользователя страница 1

MUCH WENLOCK CLASSIC

NON-BOILER SOLID FUEL STOVE

INSTALLATION AND OPERATING INSTRUCTIONS

WARNING:  This appliance is hot while in operation and retains its heat for a long period of time after
use. Children, aged or infirm persons should be supervised at all times and should not be allowed to
touch the hot working surfaces while in use or until the appliance has thoroughly cooled.

Содержание MUCH WENLOCK CLASSIC

Страница 1: ...WARNING This appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervised at all times and should not be allowed to...

Страница 2: ...tection 5 12 Specification 6 13 Lighting 7 14 Important Notes 8 15 Operating Instructions 9 16 Primary Air Settings 9 17 Recommended Fuels 9 18 Air Wash Settings 9 19 Tertiary Air System Control 9 20...

Страница 3: ...least 181cm2 or a diameter of at least 150mm It is best to connect to a chimney of the same size as con nection to a larger size may result in a somewhat less draught This appliance is not suitable f...

Страница 4: ...ls should be sealed to prevent the ingress of moisture Existing air vents should be of the correct size and unobstructed for the appli ance in use If there is an air extraction fan or other air using...

Страница 5: ...earances to com bustibles INSTALLATION CLEARANCES Clearance to combustible materials From the front 900mm From the sides 600mm From the back 700mm From the flue pipe 600mm The connector may pass throu...

Страница 6: ...Boiler Nominal Output Wood Logs 5 5 kW Solid Mineral Fuel 4 1 kW Typical refuelling intervals to obtain nominal outputs 1 5 hours wood 4 hours solid mineral fuel WARNING DO NOT OBSTRUCT PRIMARY AIR SU...

Страница 7: ...ell alight open the fire door and add more kindling of a larger size to sustain the fire Close the firedoor Do not operate this appliance with the firedoor open 8 Never use inflammable liquid i e gaso...

Страница 8: ...air ventilation to ensure plenty of air for combustion 8 Do not use as an incinerator burning rubbish household waste 9 Do not leave fire door open for long periods as this will over heat the unit cau...

Страница 9: ...ry to set properly and to season the stove RECOMMENDED FUELS This appliance has been tested using seasoned wood logs and manufactured briquetted smokeless fuel Ancit for closed appliances sized betwee...

Страница 10: ...oor and re set the spin valve to the required setting DE ASHING Never allow the ashpan to over fill as it will cause damage to the grate When ash build up becomes excessive in the fire chamber riddle...

Страница 11: ...condition observe the following tips 1 Wipe over daily with a soapy damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the...

Страница 12: ...1 ASHPAN 1 12 RATING PLATE BRACKET 2 13 AIR SLIDER PLATE 2 14 SIDE BRICK 1 15 BRICK FOR DRY SHELL 1 16 SPRING HANDLE 1 17 FIRE DOOR ASSEMBLY 1 18 HINGE WASHER 1 19 DATA PLAQUE 1 20 DRY SHELL PROTECTIO...

Отзывы: