AGA ML15CL Скачать руководство пользователя страница 6

8

Reverse osmosis, (RO), water, softened water, and de-

ionized water are not recommended as they can adversely 

affect the quality and quantity of the ice.

Water

Supply 

Line

Clamp and

Screw

Figure 11

Back view of

ice machine

NOTE

!

CAUTION

INSTALLING THE WATER SUPPLY 

Compression

fitting

Water

supply

line

Water supply

service loop

to shut off 

valve

Water valve

inlet

Water Supply

Observe and follow all local building codes when installing 

this appliance.

This ice machine must be connected to a potable cold wa-

ter supply line. delivering water pressure between a mini-

mum of 20 psi and a maximum of 120 psi.

Use 

1

4

" copper tubing for your water supply which is avail-

able at any local hardware or plumbing supply store. Route 

the 

1

4

" copper tubing to suit your installation being sure not 

to kink the tubing. Purchase enough copper tubing length to 

allow a coil to be formed behind the unit for a "service loop" 

which will allow the appliance to be pulled out from the 

installation for servicing or cleaning. (See Figure 11). Con-

nect the copper tubing to the "top side" of a cold water pipe 

to prevent the ice-maker from plugging with sediment. 

A shutoff valve is recommended on the water supply line to 

ease servicing the appliance. 

NOTE: A SELF-PIERCING 

TYPE VALVE IS NOT RECOMMENDED 

as they are prone 

to clogging with sediment which will create pressure drop 

reducing the water supply to the unit. 

Connect the copper tubing water supply to the water valve 

inlet with the compression nut fitting provided. 

IMPORTANT: 

Secure the water supply line to the back of 

the cabinet with the screw and strain relief clamp provided 

in the corner of the back panel. (See Figure 11).

Make certain all connections are watertight after installa-

tion. Form the tubing so that it will not vibrate against the 

cabinet body or kink when your appliance is moved in and 

out of position.

This ice machine is designed to make clear ice from the 

majority of water sources on a daily basis. If your results 

are unsatisfactory, your water may need to be filtered or 

treated. A water specialist can recommend proper water 

treatment.

!

CAUTION

To prevent water leaks:

• 

The water line fitting is to be used with copper tubing 

only. Do not use with plastic tubing.

• 

Do not use any thread sealers on this water line fitting.

Содержание ML15CL

Страница 1: ...glacons transparente Máquina de hielo claro ML15CL ML15CP EN Installation Operation and Maintenance Instructions FR Instructions d installation d utilisation et d entretien ES Instrucciones de instalación operación y mantenimiento ...

Страница 2: ...front to back The overall height of your Marvel appliance may be adjusted higher by turning the leveling leg out and lower by turning the leveling leg in Cabinet height adjustment dimensions are shown in Table A To adjust the leveling legs place the appliance on a solid surface and protect the floor beneath the legs to avoid scratching the floor With the assistance of another person lean the appli...

Страница 3: ... factory equipped with a power supply cord that has a three pronged grounded plug It must be plugged into a mating grounding type receptacle in accor dance with the National Electrical Code and applicable lo cal codes and ordinances see Figure 6 If the circuit does not have a grounding type receptacle it is the responsibility and obligation of the customer to provide the proper power supply The th...

Страница 4: ...em will result in surrounding water damage and or poor ice production Figure 7 CAUTION Observe and follow all local building codes when installing this ice machine and drain lines Water supply inlet Drain access in bottom of unit 43 32 10 4 cm Sanitary trap 21 4 5 7 cm 51 8 13 cm Gravity Drain no drain pump The ice machine is shipped with the drain line installed coiled and secured to the back of ...

Страница 5: ...8 inch I D tubing needs to be plumbed and connected to a sanitary sewer Refer to Figure 10 Figure 10 Drain pump vent tube Keep this open to assure air flows freely as water enters the pump reser voir Drain line coiled and secured to the back of the cabinet Uncoil route to an appropriate drain and cut to length Optional Drain Pump An optional drain pump is available if you have purchased an ice mac...

Страница 6: ...er tubing to the top side of a cold water pipe to prevent the ice maker from plugging with sediment A shutoff valve is recommended on the water supply line to ease servicing the appliance NOTE A SELF PIERCING TYPE VALVE IS NOT RECOMMENDED as they are prone to clogging with sediment which will create pressure drop reducing the water supply to the unit Connect the copper tubing water supply to the w...

Страница 7: ...el Kit This Filler Panel Kit will add 3 inches to the width of the ice machine for installation into an 18 inch wide opening Order one of the following part numbers for the color you require P N 42242831 White Filler Panel Kit P N 42242832 Black Filler Panel Kit P N 42242833 Stainless Steel Filler Panel Kit To order Call AGA Marvel customer service at 800 223 3900 177 8 45 4 cm Figure 12 ...

Отзывы: