AGA ML15CL Скачать руководство пользователя страница 2

4

!

CAUTION

Cabinet Clearance

Ventilation is required from the bottom front of the appli-

ance. Keep this area open and clear of any obstructions.  

Adjacent cabinets and counter top can be installed around 

the appliance as long as the front grille remains unob-

structed. Overlay door models with articulated hinges are 

intended for built-in applications only. 

!

CAUTION

INSTALLING YOUR APPLIANCE

Select Location

The proper location will ensure peak performance of your 

appliance. We recommend a location where the ice ma-

chine will be out of direct sunlight and away from heat 

sources. To ensure your product performs to specifications, 

the recommended installation location temperature range 

is from 55 to 90°F (13 to 32°C) for built in ice machines and 

55 to 100°F (13 to 38°C) for freestanding ice machines. Ice 

machines will not perform correctly in ambient tempera-

tures less than 55°F (13°C).

Front Grille

Do not obstruct the front grille. The openings within the 

front grille allow air to flow through the condenser heat ex

-

changer. Restrictions to this air flow will result in increased 

energy usage, loss of cooling capacity and low ice produc-

tion. For this reason it is important this area not be obstruct-

ed and the grille openings kept clean. AGA MARVEL does 

not recommend the use of a custom made grille as air flow 

may be restricted. (See Figure 2).

Leveling Legs

Adjustable legs at the front and rear corners of the appli-

ance should be set so the unit is firmly positioned on the 

floor and level from side to side and front to back. The 

overall height of your Marvel appliance may be adjusted 

higher (by turning the leveling leg out) and lower (by turning 

the leveling leg in). Cabinet height adjustment dimensions 

are shown in Table "A".

To adjust the leveling legs, place the appliance on a solid 

surface and protect the floor beneath the legs to avoid 

scratching the floor. With the assistance of another person, 

lean the appliance back to access the front leveling legs. 

Raise or lower the legs to the required dimension by turning 

the legs. Repeat this process for the rear by tilting the appli-

ance forward using caution. On a level surface check the 

appliance for levelness and adjust accordingly.

The front grille screws may be loosened to raise and lower 

the grille to the desired height. When adjustment is com-

plete tighten the two front grille screws. (See Figure 5).

Rear 

Leveling 

Legs

Figure 2

Front Leveling

        Legs

Front Grille, 

keep this area 

open.

!

WARNING

WARNING - Help Prevent Tragedies

Child entrapment and suffocation are not problems of 

the past. Junked or abandoned refrigerators are still 

dangerous - even if they sit out for "just a few hours".

If you are getting rid of your old refrigerator, please 

follow the instructions below to help prevent acci-

dents.

Before you throw away your old refrigerator or 

freezer:

•  Take off the doors or remove the drawers.

•  Leave the shelves in place so children may not 

easily climb inside.

If the appliance was shipped, handled, or stored in other 

than an upright position for any period of time, allow the ap-

pliance to sit upright for a period of at least 24 hours before 

plugging in. This will assure oil returns to the compressor. 

Plugging the appliance in immediately may cause damage 

to internal parts.

Содержание ML15CL

Страница 1: ...glacons transparente Máquina de hielo claro ML15CL ML15CP EN Installation Operation and Maintenance Instructions FR Instructions d installation d utilisation et d entretien ES Instrucciones de instalación operación y mantenimiento ...

Страница 2: ...front to back The overall height of your Marvel appliance may be adjusted higher by turning the leveling leg out and lower by turning the leveling leg in Cabinet height adjustment dimensions are shown in Table A To adjust the leveling legs place the appliance on a solid surface and protect the floor beneath the legs to avoid scratching the floor With the assistance of another person lean the appli...

Страница 3: ... factory equipped with a power supply cord that has a three pronged grounded plug It must be plugged into a mating grounding type receptacle in accor dance with the National Electrical Code and applicable lo cal codes and ordinances see Figure 6 If the circuit does not have a grounding type receptacle it is the responsibility and obligation of the customer to provide the proper power supply The th...

Страница 4: ...em will result in surrounding water damage and or poor ice production Figure 7 CAUTION Observe and follow all local building codes when installing this ice machine and drain lines Water supply inlet Drain access in bottom of unit 43 32 10 4 cm Sanitary trap 21 4 5 7 cm 51 8 13 cm Gravity Drain no drain pump The ice machine is shipped with the drain line installed coiled and secured to the back of ...

Страница 5: ...8 inch I D tubing needs to be plumbed and connected to a sanitary sewer Refer to Figure 10 Figure 10 Drain pump vent tube Keep this open to assure air flows freely as water enters the pump reser voir Drain line coiled and secured to the back of the cabinet Uncoil route to an appropriate drain and cut to length Optional Drain Pump An optional drain pump is available if you have purchased an ice mac...

Страница 6: ...er tubing to the top side of a cold water pipe to prevent the ice maker from plugging with sediment A shutoff valve is recommended on the water supply line to ease servicing the appliance NOTE A SELF PIERCING TYPE VALVE IS NOT RECOMMENDED as they are prone to clogging with sediment which will create pressure drop reducing the water supply to the unit Connect the copper tubing water supply to the w...

Страница 7: ...el Kit This Filler Panel Kit will add 3 inches to the width of the ice machine for installation into an 18 inch wide opening Order one of the following part numbers for the color you require P N 42242831 White Filler Panel Kit P N 42242832 Black Filler Panel Kit P N 42242833 Stainless Steel Filler Panel Kit To order Call AGA Marvel customer service at 800 223 3900 177 8 45 4 cm Figure 12 ...