GAS CONTROL VALVE (GCV) - ASSESSMENT.
Ensure Stove is cool before commencing any work.
Ensure batteries are new, mounted correctly, and connections are good.
Start with the valve in standby position
– slide switch in
ON
(Power Isolator Switch - Sliding)
(I) position, red light on valve off, and fire burner also off.
Press the power button, marked , and hold for approx. 1 second, or until the red LED lights up, then
release. This should start the ignition sequence, and within a few seconds a repetitive spark should be
produced at the electrode.
The fire may make up to 3 automatic attempts to ignite. Each ignition cycle takes 15-30 seconds, with a
pause of approx. 10 seconds between each cycle. Multiple attempts
DOES NOT
signify that there is a
fault, each fire and installation is unique, and may account for this.
If the fire fails to ignite after 3 automatic cycles, the red light on the valve will stay permanently lit,
indicating valve lockout. A connected display handset will also return the error code E00. To reset the
lockout press the power button to return the valve to standby, and try normal start-up process again.
If problem persists, and valve repeatedly goes to lockout,
refer to the Cleaning & Servicing
section. It
is possible that the valve has become contaminated with debris, and requires cleaning to restore normal
operation.
If the fire does not light and/or…
There is an error code EXX (where XX is a two-digit number) displayed on the handset.
The red LED on the valve is flashing like a heartbeat.
The display handset is showing low battery.
Please then refer to troubleshooting section and error codes section for further information.
Power Isolator Switch (Sliding) this turns the power onto the Gas Control Valve (GCV)
Red Indicator
Light
AGA
-
G
AS
C
ONTROL
V
ALVE
(GCV)
Power ON Start Button