Especially Airtight Properties:-
If the stove is being fitted in a property where the
design air permeability is less than 5m
3
/ (h.m
2
) (nor-
mally newer properties built from 2006), then a per-
manent ventilation must be fitted to provide 550mm
2
of ventilation for each kW of rated output. If a
draught stabiliser is also fitted then the requirement
is 850mm
2
per kW of rated output.
If spillage occurs following the above operation, an
additional air vent of sufficient size to prevent this
occurrence should be installed.
PERMANENT AIR VENT
The stove requires an adequate air supply in order
for it to operate safely and efficiently. The installer
may have fitted a permanent air supply vent into the
room in which the stove is installed to provide com-
bustion and/or ventilation air. This air vent should
not under any circumstances be shut off or sealed.
Extractor Fan
There must not be an extractor fan fitted in the same
room as the stove as this can cause the stove to
emit smoke and fumes into the room.
COMMISSIONING & HANDOVER
On completion of the installation allow a suitable
period of time for any fire cement and mortar to dry
out, when a small fire may be lit and checked to
ensure the smoke and fumes are taken from the
stove up the chimney and emitted safely to the
atmosphere.
Do not run at full output for at least
24 hours.
On completion of the installation and commissioning
ensure that the operating instructions for the stove
are left with the customer. Ensure to advise the cus-
tomer on the correct use of the appliance with the
fuels likely to be used on the stove and warn them to
use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes
be emitted from the stove. The customer should be
warned to use a fire guard to BS 8423:2002 in the
presence of children, aged and/or infirm persons.
5
LOCATION
There are several conditions to be considered in
selecting a location for your stove.
A. Position in the area to be heated - central loca-
tions are usually best. If situated in an alcove,
site as far forward as possible, to provide more
heat to the room.
B. Allowances for proper clearances to com -
bustibles.
CLEARANCE TO COMBUSTIBLES
It is recommended that this appliance is sited next to
and on a non-combustible surface. A minimum all
round clearance of 100mm will allow air circulation
and not impede the performance of the stove. If it is
necessary to site the stove near to a combustible
surface a minimum clearance of 475mm to side
walls and 550mm to rear wall must be maintained.
The connector may pass through walls or partitions
constructed of combustible materials provided the
connector is either listed for wall pass-through or is
routed through a device listed for a wall pass-
through and is installed in accordance with the con-
ditions of the listing. Any unexposed metal that is
used as part of a wall pass-through system is
exposed to flue gases shall be constructed of stain-
less steel or other equivalent material that will resist
corrosion, softening, or cracking from flue gas at
temperatures up to 982°C.
FLOOR PROTECTION
It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.