3

the appliance and should not be less than (4in) internal 
diameter.

7. In the event of an extractor fan being fitted in the vicinity of

the range, compensatory ventilation will be required to 
satisfy the demands of the fan without influencing
combustion efficiency or chimney flue condition.

Direct Vent - Models GC and GE

The location chosen for the appliance must permit the
provision of a satisfactory flue termination.
The location must also provide adequate space for servicing
and air circulation around the range.
Should the installation of the appliance be in an unusual
location or restricted space, special procedures may be
necessary and the following current codes give detailed guide
lines on this aspects:

U.S.: 

The National Fuel Gas Code ANSI Z223.

1-latest edition.

Canada: 

The CAN/CGA B -149 installation codes.

The following notes are intended to give general guidance.
1. The range must be installed so that the flue terminal is

exposed to the external air and terminal clearances comply
with:
In 

U.S.

: The National Fuel Gas Codes ANSI Z223 1-latest 

edition Section 7.7.
In 

Canada

: CAN/CGA-B149 installation code.

2. Termination should be on a clear expanse of wall, the 

terminal being preferably not less than 355mm (14in) away
from a corner, recess of projection.

3. A hole must be cut through an outside wall as indicated in 
Fig. 6 with the hole rising from inside to outside face 
of wall.

DO NOT

install the terminal:-

(a) Within 300mm (12in) measured vertically, from the 

bottom of an openable window, air vent or any other 
ventilating opening.

(b) Within 300mm (12in) above adjacent ground level.
(c) Within 600mm (24in) of any surface  facing the 

terminal.

(d) Within 355mm (14in) (

U.S

.) or

300mm (12in) (

Canada

) below eaves or balcony.

The direct vent terminal must be protected by a terminal
protective guard installed over the terminal to prevent
unauthorised contact with hot terminal surfaces.
See Fig. 8.
4. All jointing faces providing primary air and flue exhaust 

paths, must be sealed in an airtight fashion, with particular
emphasis on the following locations:
(a) Air intake tube joints to be sealed with silicone adhesive

provided.

(b) Combustion chamber top sealed with a fire-cemented 

gasket to the outer barrel.

(c) Fire cement joints between underside contact faces of 
hotplates and simmering plate with cement provided.
(d) Gasket between flue intake/exhaust manifold.

Gasket provided.

The air inlet/products outlet direct vent, and the terminal of the
appliance must not be less than 300mm (12in) to combustible
material. The terminal is suitable for walls of 150mm (6in) to
355mm (14in) overall thickness.
For special lengths up to 610mm (24in), consult your local Aga
Distributor.

If the cooker is to stand in a recess or against a wall which is
to be tiled, in no circumstances should the tiles overlap the
range top plate.

NOTE: A GAS CONTROL VALVE MUST BE INSTALLED.
IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT
SUPPLIED).
9.5mm (3/8in) N.P.T. Male connection near the front of the
range on the L.H. or R.H. side - Optional.

ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.

Maximum Heat Input: 4.4 kw (15,000 Btu/h)

WALL TILING

GAS SUPPLY - U.S. PIPE THREADS

Содержание GC Open Flue Range

Страница 1: ...rial for a minimum thickness of 12mm 1 2in and comply with current Building Regulations and National Fire Laws The wall behind the cooker draft hood and flue connector must have a minimum air gap of 5...

Страница 2: ...ng types of vent i Type B Vent 25mm 1in minimum ii Single wall vent connector 150mm 6in minimum Listed connectors passing through combustible walls and partitions must be guarded by a ventilated metal...

Страница 3: ...ly from the bottom of an openable window air vent or any other ventilating opening b Within 300mm 12in above adjacent ground level c Within 600mm 24in of any surface facing the terminal d Within 355mm...

Страница 4: ...ly piping system at test pressures equal to or less than 1 2 psig 3 5kPa The model and serial numbers for this appliance are found on the name plate These numbers must be used when requesting advice f...

Страница 5: ...tablished release the control knob gradually and rotate anti clockwise to its low fire position whereupon the main burner will light Leave in the low fire position for at least 30 minutes NOTE Any att...

Страница 6: ...ows Description 1 Pilot Thermocouple 2 Main Burner 3a Pilot Burner Assembly N G 3b Pilot Burner Assembly L P G 4 Combination Gas Valve 5a Pressure Regulator N G 5b Pressure Regulator L P G 6 Combustio...

Страница 7: ...7 Fig 12 Pilot Thermocouple DESN 512827...

Страница 8: ...he PTFE insulation cable remains intact and strip is firmly connected to the spark electrode Clean any carbon away from the electrode 7 Refit combustion chamber baffle 8 DIRECT VENT MODEL ONLY GC AND...

Отзывы: