IMPORTANT
PLEASE READ THROUGH COMPLETELY BEFORE COMMENCING INSTALLATION.
WARNING:
THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE
REGULATIONS IN FORCE AND ONLY USED IN A WELL VENTILATED SPACE, READ THE
INSTRUCTIONS BEFORE INSTALLING OR USING THIS APPLIANCE.
PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS (TYPE
OF GAS AND GAS PRESSURE) AND THE ADJUSTMENTS OF THE APPLIANCE ARE
COMPATIBLE.
THE ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE
, WHICH IS SITUATED INSIDE THE HOB UNIT ON THE METAL BASE.
This appliance is not connected to a combustion products evacuation device. It must be installed
and connected in accordance with current installation regulations. Particular attention shall be
given to the relevant requirements regarding ventilation (B.S. 5440 Part 2). It should be in
accordance also with any relevant requirements of the gas Region and Local Authority.
In your own interests, and that of safety and compliance with the law, all gas appliances must be
installed by a competent person. Failure to install the appliances correctly could lead to
prosecution.
On completion, test the gas installation for tightness.
WARNING: THIS APPLIANCE MUST BE EARTHED.
The appliance is designed for the voltage stated on the data plate.
Any adjacent walls that project above the height of the hob must be of heat resistant material.
Surfaces over the top of the hob must not be closer than 650mm.
THE ISOLATOR SHOULD
NOT
BE POSITIONED IMMEDIATELY ABOVE THE HOB OR THE
MAIN COOKER, BUT
MUST
BE SITED WITHIN 1.5 METRES OF THE APPLIANCE.
The hob must be wired and installed by a Qualified Engineer in accordance with the Current
National Wiring Regulations and also any local regulations which may apply.
The appliance requires a 3 amp, 230 volt ~ 50 Hz supply.
The method of connection to the mains supply should ensure complete electrical isolation of the
appliance by the use of a fused double pole switch having a contact separator of at least 3mm
serving only the appliance. The point of connection should be accessible and adjacent to the
appliance. The installation should be protected by a 30 mA Residual Current Circuit Breaker
(RCCB).
IMPORTANT
The wires in the mains lead on this appliance are coloured in accordance with the following:
Green/Yellow - Earth
Blue - Neutral
Brown - Live
3
GENERAL REQUIREMENTS