Water Supply Requirements

Gather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed 

here.
TOOLS NEEDED:  

IMPORTANT:

All installations must meet local  plumbing code requirements.
Do not use a piercing-type or 

³⁄16

" (4.76 mm) saddle valve 

which reduces water flow and clogs more easily.
Use copper tubing and check for leaks. Install copper tubing 

only in areas where the household temperatures will remain 

above freezing.
For models with water filters, the disposable water filter 

should be replaced at least every 6 months. 

Water Pressure

A cold water supply with water pressure of between 35 and 

120 psi (241 and 827 kPa) is required to operate the water 

dispenser and ice maker. If you have questions about your water 

pressure, call a licensed, qualified plumber.

Reverse Osmosis Water Supply

IMPORTANT:  The pressure of the water supply coming out of a 

reverse osmosis system going to the water inlet valve of the 

refrigerator needs to be between 35 and 120 psi (241 and 

827 kPa).
If a reverse osmosis water filtration system is connected to your 

cold water supply, the water pressure to the reverse osmosis 

system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than 

40 to 60 psi (276 to 414 kPa):

Check to see whether the sediment filter in the reverse 

osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 

after heavy usage.
If your refrigerator has a water filter, it may further reduce the 

water pressure when used in conjunction with a reverse 

osmosis system. Remove the water filter. See “Water Filtration 

System.”

If you have questions about your water pressure, call a licensed, 

qualified plumber.

Connect the Water Supply

Read all directions before you begin.
IMPORTANT:  If you turn on the refrigerator before the water line is 

connected, turn off the ice maker to avoid excessive noise or 

damage to the water valve.

Connect to Water Line

1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long 

enough to clear line of water.

3. Find a 

¹⁄2

" to 1

¹⁄4

" (12.7 mm to 31.8 mm) vertical cold water 

pipe near the refrigerator.
IMPORTANT:

Make sure it is a cold water pipe. 
Horizontal pipe will work, but the following procedure 

must be followed: Drill on the top side of the pipe, not the 

bottom. This will help keep water away from the drill. This 

also keeps normal sediment from collecting in the valve.

4. Determine the length of copper tubing you need. Measure 

from the connection on the lower right rear of the refrigerator 

to the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use 

¹⁄4

" (6.35 mm) O.D. (outside diameter) copper tubing. Be sure 

both ends of copper tubing are cut square.

5. Using a cordless drill, drill a 

¹⁄4

" hole in the cold water pipe you 

have selected.

 

6. Fasten the shutoff valve to the cold water pipe with the pipe 

clamp. Be sure the outlet end is solidly in the 

¹⁄4

" drilled hole in 

the water pipe and that the washer is under the pipe clamp. 

Tighten the packing nut. Tighten the pipe clamp screws slowly 

and evenly so the washer makes a watertight seal. Do not 

overtighten. 

7. Slip the compression sleeve and compression nut on the 

copper tubing as shown. Insert the end of the tubing into the 

outlet end squarely as far as it will go. Screw compression nut 

onto outlet end with adjustable wrench. Do not overtighten or 

you may crush the copper tubing. 

8. Place the free end of the tubing in a container or sink, and turn 

ON the main water supply. Flush the tubing until water is clear. 

Turn OFF the shutoff valve on the water pipe. 

Flat-blade screwdriver

7⁄16

" and 

¹⁄2

" Open-end or two 

adjustable wrenches

¹⁄4

" Nut driver

¹⁄4

" Drill bit

Cordless drill

A. Cold water pipe
B. Pipe clamp

C. Copper tubing 
D. Compression nut

E. Compression sleeve

F. Shutoff valve

G. Packing nut

F
G

A
B

C

D
E

Содержание AMLFDR20

Страница 1: ...32 41012942 revA 12 7 12 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potentia...

Страница 2: ...emove ground prong Do not use an adapter Do not use an extension cord Disconnect power before servicing Replace all parts and panels before operating Remove doors from your old refrigerator Use nonfla...

Страница 3: ...upply is required It is recommended that a separate circuit serving only your refrigerator be provided Use an outlet that cannot be turned off by a switch Do not use an extension cord NOTE Before perf...

Страница 4: ...90 4 10 2 cm gap for door swing 25 63 5 cm counter depth 36 1 2 92 7 cm 24 1 2 62 3cm 70 1 4 178 4cm 4 Model AMLFDR20 Dimensions 43 3 8 110 2 cm with fridge door open 24 1 8 61 3 cm 69 15 16 177 6cm...

Страница 5: ...u begin IMPORTANT If you turn on the refrigerator before the water line is connected turn off the ice maker to avoid excessive noise or damage to the water valve Connectto WaterLine 1 Unplug refrigera...

Страница 6: ...ith a second wrench turn the compression nut on the copper tubing counterclockwise to completely tighten Do not overtighten 6 Check connection by pulling on copper tubing Attach the plastic water line...

Страница 7: ...just the leveling screw on the lower side of the refrigerator Using a hex driver turn the screw clockwise to raise that side of the refrigerator until the doors are aligned It may take several turns o...

Страница 8: ...ours between adjustments for the temperature to stabilize AdditionalControl CenterFeatures Max Ice The Max Ice feature assists with temporary periods of heavy ice use by increasing ice production Pres...

Страница 9: ...played press the Refrigerator or touch pads to change the preference status 3 Set your preferences by pressing and holding the Door Alarm touch pad for 3 seconds or by shutting the refrigerator compar...

Страница 10: ...d lter to eject Always dispense water for at least 2 minutes before removing the lter or blue bypass cap 1 Turn lter counterclockwise to remove 2 Remove sealing label from replacement lter and insert...

Страница 11: ...ing Plug in a lamp to see if the outlet is working Household fuse blown or circuit breaker tripped Replace the fuse or reset the circuit breaker If the problem continues call an electrician Are contro...

Страница 12: ...t close completely earlier in this section Large amount of ice recently removed Allow 24 hours for ice maker to produce more ice Ice cube jammed in the ice maker ejector arm Remove ice from the ejecto...

Страница 13: ...ltration system connected to your cold water supply This can decrease water pressure See Water Supply Requirements Water is leaking fromthe dispensersystem NOTE One or two drops of water after dispen...

Страница 14: ...uction Chlorine Taste Odor Particulate Class I 50 reduction 85 reduction 2 00 mg L 14 000 000 mL 2 0 mg L 10 At least 10 000 particles mL 0 06 mg L 370 000 mL 0 050625 mg L 196 666 mL 97 00 97 40 97 5...

Страница 15: ...al codes low voltage failure to provide necessary maintenance or other unreasonable use 7 Parts of service not supplied or designated by the factory 8 9 Alteration or the removal or defacing of the se...

Страница 16: ...16...

Страница 17: ...autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient AVERTISSEMENT r frig rateur prendre quelques pr cautions fondamentale...

Страница 18: ...MENT Risque de suffoquer Enlever les portes de votre vieux r frig rateur Le non respect de cette instruction peut causer un d c s ou des l sions c r brales Renseignements importants propos de la mise...

Страница 19: ...x cuter tout type d installation nettoyage ou remplacement d une ampoule d clairage tourner la commande r glage du thermostat du r frig rateur ou du cong lateur selon le mod le OFF arr t et d connecte...

Страница 20: ...110 2cm with fridge door open 24 1 8 61 3cm 69 15 16 177 6cm 68 1 2 174cm Body Width 35 5 8 90 5 cm Hinge 3 8 front leg adjusters front stabilizers Largeur ext rieure charni re jambe avant r gleurs av...

Страница 21: ...froide verticale de 1 12 7 mm 31 8 mm pr s du r frig rateur IMPORTANT S assurer qu il s agit d un conduit d eau froide Un conduit horizontal fonctionnera mais le proc d suivant doit tre suivi percer...

Страница 22: ...alisation d eau en plastique la caisse du r frig rateur l aide d une bride en P 7 Ouvrirla canalisation d eau du r frig rateur et inspecter s il y a des fuites Corriger toute fuite Achever l installat...

Страница 23: ...se que l autre ajuster la vis de nivellement du c t du r frig rateur le plus bas l aide d un tourne crou t te hexagonale de tourner la vis de nivellement dans le sens horaire a n d lever ce c t du r f...

Страница 24: ...ature dans le compartiment de r frig ration ou de cong lation utiliser les r glages indiqu s dans le tableau ci dessous comme guide Pour ajusterles r glages de temp rature Lorsqu on appuie une premi r...

Страница 25: ...ool pour revenir au point de r glage normal du r frig rateur REMARQUE La caract ristique Max Cool s teindra automatiquement au bout de 12 heures environ FilterReset r initialisation du re La commande...

Страница 26: ...machine gla ons viter de brancher la machine gla ons un approvisionnement d eau adoucie Les produits chimiques adoucisseurs d eau tels que le sel peuvent endommager des pi ces de la machine gla ons et...

Страница 27: ...ions toutes les odeurs form es dans une section seront transf r es l autre Vous devez nettoyer fond les deux sections pour liminer les odeurs Pour viter le transfert d odeurs et l ass chement des alim...

Страница 28: ...e Brancher une lampe pour voir si la prise fonctionne Un fusible est il grill ou un disjoncteur s est il d clench Remplacer le fusible ou r armer le disjoncteur Si le probl me persiste appeler un lect...

Страница 29: ...andes sont elles correctement r gl es pour les conditions existantes Ajuster les commandes un cran plus froid V ri r la temp rature au bout de 24 heures Voir Utilisation de la des commande s Il y a un...

Страница 30: ...t il connect l alimentation en eau et le robinet d arr t d eau est il ouvert Brancher le r frig rateur l alimentation en eau et ouvrir le robinet d arr t d eau compl tement La canalisation de la sourc...

Страница 31: ...A uent moyen Concentration dans l eau traiter E uent maximal E uent moyen de r d minimale de r d moyenne Go t odeur de chlore Particules classe I r duction de 50 r duction de 85 2 00 mg L 14 000 000...

Страница 32: ...non conforme aux codes lectriques basse tension d faut d entretien n cessaire ou tout autre utilisa tion d raisonnable 7 Pi ces de rechange ou services non fournis ou d sign es par l usine 8 Accident...

Отзывы: