PARLED100-Z 

Zoom adjustment ..................................................................................................... 9°/15°/20°/25°/30° 
Dimensions ...........................................................................................................491 x 275 x 224mm 
Weight ........................................................................................................................................ 3.4kg 
 

 

INSTALLATION AND CONNECTION 

This fixture may be mounted in any position, provided there is adequate room for ventilation. It is important never to obstruct 
the fan or vents pathway. When selecting installation location, take into consideration lamp replacement access and routine 
maintenance. Safety cables must always be used.  Never mount in places where the fixture will be exposed to rain, high 
humidity, extreme temperature changes or restricted ventilation. 
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his 
service agent or a similar qualified person in order to avoid a hazard. 
Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the light will 
not fall from the truss, use the safety cable go through the truss and bracket of the light as a supporting, to avoid the light to 
fall down. There is no entrance to the work area during mounting. Periodically check if the safety cable has fretted away or 
clamp is loosened. We will not take any responsibility for damages caused by a badly installed unit. 
 

Fixture Linking

 

You will need a serial data link to run light shows of one or 
more fixtures using a DMX-512 controller or to run 
synchronized shows on two or more fixtures set to a 
master/slave operating mode. The combined number of 
channels required by all fixtures on a serial data link 
determines the number of fixtures that the data link can 
support. 

Important

: Fixtures on a serial/data link must be daisy chained in one single line.    Maximum recommended serial data link 

distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures 

 

CABLE CONNECTORS 

Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 
 

Содержание 16-2800

Страница 1: ...10 00 0W W W WA AR RM M W WH HI IT TE E L LE ED D P PA AR R W WI IT TH H M MA AN NU UA AL L B BE EA AM M A AN NG GL LE E A AD DJ JU US ST TM ME EN NT T PARLED100 Z 16 2800 GB INSTRUCTION MANUAL F MAN...

Страница 2: ...re to replace with same fuse size and type Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is...

Страница 3: ...ging make sure the light will not fall from the truss use the safety cable go through the truss and bracket of the light as a supporting to avoid the light to fall down There is no entrance to the wor...

Страница 4: ...xture must have a specific starting address When receiving signal transmission every fixture will receive channels control signals for its own starting address The user can set several fixtures to the...

Страница 5: ...to adjust the address from 001 to 512 Once the address has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and press the...

Страница 6: ...thout any change after 8 seconds Back to the functions without any change press the MENU button again DMX State Select press the ENTER button Use the DOWN and UP button to select Blackout or Hold the...

Страница 7: ...e functions press the MENU button FIXTURE HOURS To select press the ENTER button to show the FIXTURE HOURS on the display and the display will show the number of working hours of the unit To go back t...

Страница 8: ...The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered to by a skilled installer...

Страница 9: ...pr sente exactement les m mes caract ristiques que l ancien S curisez l appareil sur le dispositif de fixation au moyen d une cha ne Ne portez jamais l appareil en le tenant par le bo tier Tenez le p...

Страница 10: ...e la structure en passant un c ble d acier dans la structure et l trier Personne ne doit se trouver en dessous de la zone de travail pendant l installation Nous d clinons toute responsabilit pour des...

Страница 11: ...sur le bouton MENU jusqu ce que la fonction d sir e s affiche sur l cran S lectionnez la fonction en appuyant sur la touche ENTER et l affichage clignote Utilisez les boutons DOWN et UP pour changer l...

Страница 12: ...immer Mode 1 Dimmer Mode 4 au moyen des touches DOWN et UP Appuyez sur ENTER pour confirmer Pour revenir au menu pr c dent appuyez sur le bouton MENU pendant une seconde ou attendez 8 secondes pour qu...

Страница 13: ...pour s lectionner luminosite d000 d100 ou stroboscope S000 S100 Une fois que le mode a t s lectionn appuyez sur la touche ENTER pour valider Pour revenir des fonctions sans aucun changement appuyez s...

Страница 14: ...apide 169 208 Stroboscope al atoire 209 255 Stroboscope al atoire 250 255 Ouvert Diagnostic de d faillance Ci apr s vous trouverez quelques probl mes courants qui peuvent survenir pendant le fonctionn...

Страница 15: ...chtige Informationen ber Installation Gebrauch und Instandhaltung des Ger ts Die Anleitung f r sp tere Bezugnahme aufbewahren und an den n chsten Bediener weitergeben Stets die Netzspannung vor Anschl...

Страница 16: ...standsgesetz umgekehrtes Abstandsgesetz Manuell einstellbare Abstrahlwinkel von 9 bis 30 Technische Daten Versorgung 100 240Vac 50 60Hz Verbrauch 105W Abstrahlwinkel 9 15 20 25 30 Abmessungen 491 x 27...

Страница 17: ...Men s und der gew hlten Funktionen LED Anzeige Anzeige der eingestellten Betriebsart Menu Tasten Sicherung F3 15A Netzein ausgang Powercon Verbinder DMX Ein Ausgang Alle DMX Kabel m ssen 3 pol XLR Ver...

Страница 18: ...den Funktionen zur ck zu schalten die MENU Taste 1 Sekunde lang dr cken oder 8 Sekunden warten Dimmer mode 1 Dimmer mode 2 Dimmer mode 3 Dimmer mode 4 Optisch linear Abstandsgesetz Umgekehrtes Abstan...

Страница 19: ...e dr cken Um ohne Ver nderung der Einstellungen zu den Funktionen zur ck zu schalten die MENU Taste 1 Sekunde lang dr cken oder 8 Sekunden warten SELBSTTEST ENTER Taste dr cken bis TEST erscheint Das...

Страница 20: ...ie ein anderes DMX Steuerpult 5 Pr fen ob die DMX Kabel entlang von Hochspannungskabel liegen die dies DMX Schnittstelle st ren oder besch digen Reinigung und Instandhaltung des Ger ts Schalten Sie da...

Отзывы: