Safety Instructions

 

Please read these instructions carefully, they include important information about the installation, usage and maintenance of 
this product. 
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives this 
instruction booklet. 
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not 
higher than that stated on the decal or rear panel of the fixture. 
• This product is intended for indoor use only! 
It is essential that the device is earthed. A qualified person must carry out the electric connection. 
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials 
close to the unit while operating. 
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that 
no ventilation slots are blocked. 
• Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size and 
type. 
• Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles. 
• Maximum ambient temperature (Ta) is 104° F (40°C).    Do not operate the fixture at temperatures higher than this. 

 

Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand during its operation. Turn off the 

power and allow about 15 minutes for the unit to cool down before replacing or serving. 

• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical 
assistance center. Always use the same type of spare parts. 
• Don’t connect the device to a dimmer pack. 
• Make sure the power cord is never crimped or damaged. 
• Never disconnect the power cord by pulling or tugging on the cord. 
• Avoid direct eye exposure to the light source while it is on. 
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device 
shall remain readily operable. 

 

Features 

 

2x DMX channels 

 

Warm white W°K 

 

Optical linear, square law, inverted square law and S-curve dimmer 

 

Adjustable beam angles from 9° to 30° 

 

Specifications 

Power supply ...................................................................................................... 100-240Vac 50/60Hz 
Consumption ............................................................................................................................. 105W 
LED source ..................................................................................................................... 98W COB LED 
Color temperature .................................................................................................................... 2700°K 

GB 

Содержание 16-2800

Страница 1: ...10 00 0W W W WA AR RM M W WH HI IT TE E L LE ED D P PA AR R W WI IT TH H M MA AN NU UA AL L B BE EA AM M A AN NG GL LE E A AD DJ JU US ST TM ME EN NT T PARLED100 Z 16 2800 GB INSTRUCTION MANUAL F MAN...

Страница 2: ...re to replace with same fuse size and type Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is...

Страница 3: ...ging make sure the light will not fall from the truss use the safety cable go through the truss and bracket of the light as a supporting to avoid the light to fall down There is no entrance to the wor...

Страница 4: ...xture must have a specific starting address When receiving signal transmission every fixture will receive channels control signals for its own starting address The user can set several fixtures to the...

Страница 5: ...to adjust the address from 001 to 512 Once the address has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and press the...

Страница 6: ...thout any change after 8 seconds Back to the functions without any change press the MENU button again DMX State Select press the ENTER button Use the DOWN and UP button to select Blackout or Hold the...

Страница 7: ...e functions press the MENU button FIXTURE HOURS To select press the ENTER button to show the FIXTURE HOURS on the display and the display will show the number of working hours of the unit To go back t...

Страница 8: ...The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered to by a skilled installer...

Страница 9: ...pr sente exactement les m mes caract ristiques que l ancien S curisez l appareil sur le dispositif de fixation au moyen d une cha ne Ne portez jamais l appareil en le tenant par le bo tier Tenez le p...

Страница 10: ...e la structure en passant un c ble d acier dans la structure et l trier Personne ne doit se trouver en dessous de la zone de travail pendant l installation Nous d clinons toute responsabilit pour des...

Страница 11: ...sur le bouton MENU jusqu ce que la fonction d sir e s affiche sur l cran S lectionnez la fonction en appuyant sur la touche ENTER et l affichage clignote Utilisez les boutons DOWN et UP pour changer l...

Страница 12: ...immer Mode 1 Dimmer Mode 4 au moyen des touches DOWN et UP Appuyez sur ENTER pour confirmer Pour revenir au menu pr c dent appuyez sur le bouton MENU pendant une seconde ou attendez 8 secondes pour qu...

Страница 13: ...pour s lectionner luminosite d000 d100 ou stroboscope S000 S100 Une fois que le mode a t s lectionn appuyez sur la touche ENTER pour valider Pour revenir des fonctions sans aucun changement appuyez s...

Страница 14: ...apide 169 208 Stroboscope al atoire 209 255 Stroboscope al atoire 250 255 Ouvert Diagnostic de d faillance Ci apr s vous trouverez quelques probl mes courants qui peuvent survenir pendant le fonctionn...

Страница 15: ...chtige Informationen ber Installation Gebrauch und Instandhaltung des Ger ts Die Anleitung f r sp tere Bezugnahme aufbewahren und an den n chsten Bediener weitergeben Stets die Netzspannung vor Anschl...

Страница 16: ...standsgesetz umgekehrtes Abstandsgesetz Manuell einstellbare Abstrahlwinkel von 9 bis 30 Technische Daten Versorgung 100 240Vac 50 60Hz Verbrauch 105W Abstrahlwinkel 9 15 20 25 30 Abmessungen 491 x 27...

Страница 17: ...Men s und der gew hlten Funktionen LED Anzeige Anzeige der eingestellten Betriebsart Menu Tasten Sicherung F3 15A Netzein ausgang Powercon Verbinder DMX Ein Ausgang Alle DMX Kabel m ssen 3 pol XLR Ver...

Страница 18: ...den Funktionen zur ck zu schalten die MENU Taste 1 Sekunde lang dr cken oder 8 Sekunden warten Dimmer mode 1 Dimmer mode 2 Dimmer mode 3 Dimmer mode 4 Optisch linear Abstandsgesetz Umgekehrtes Abstan...

Страница 19: ...e dr cken Um ohne Ver nderung der Einstellungen zu den Funktionen zur ck zu schalten die MENU Taste 1 Sekunde lang dr cken oder 8 Sekunden warten SELBSTTEST ENTER Taste dr cken bis TEST erscheint Das...

Страница 20: ...ie ein anderes DMX Steuerpult 5 Pr fen ob die DMX Kabel entlang von Hochspannungskabel liegen die dies DMX Schnittstelle st ren oder besch digen Reinigung und Instandhaltung des Ger ts Schalten Sie da...

Отзывы: