9
4.
Finally,
insert
the
AC
connection
socket
into
the
AC
socket
on
the
inverter
audibly
snaps
into
place.
DANGER!
Danger
to
life
due
to
high
voltages
in
the
inverter.
•
Do
not
switch
on
the
circuit
breaker
until
the
PV
generator
has
been
connected
and
the
inverter
is
securely
closed.
5.3
Connection
of
the
PV
Generator
(DC)
CAUTION!
Load
Disconnection
Unit
You
must
install
an
individual
circuit
breaker
on
the
DC
side
out
of
each
inverter,
in
order
that
the
inverter
can
be
safely
installed.
5.3.1
Conditions
for
the
DC
Connection
•
The
connected
PV
modules
must
meet
following
requirements
–
Same
type
–
Same
number
–
Identical
alignment
–
Identical
tilt
•
The
following
limit
values
at
the
DC
input
of
the
inverter
must
not
be
exceeded
(connecting
to
a
higher
voltage
will
destroy
the
device):
Anyhome
Maximum
input
voltage
Maximum
input
current
1.5KW
500V
8A
2KW
500V
12A
5.3.2
Assembling
the
DC
Plug
Connector
In
order
to
connect
to
the
inverter,
all
connection
cables
of
the
PV
modules
must
be
equipped
with
the
DC
plug
connectors
provided.
You
will
find
the
necessary
DC
plug
connector
for
DC
connection
in
the
delivery.