39
A46
-
A47
-
A48
-
A49
-
A50
-
A51
-
A52
-
A53
-
A54
-
A55
-
A56
Pv24AbnormalFault
Battery Fault
B01
PcsBatOverVoltFault
Battery voltage over
or under
1. Check
inverters
connected
battery lines and connectors broken
or loose connect,
2. Carry out rectification if broken
or loose.
3. Checking battery voltage is
abnormal or not, then maintenance
or change new battery.
B02
PcsBatUnderVoltFault
B03
PcsBatInsOverVoltFaul
B04
PcsBatReversedFault
Bat. (+) and Bat. (-)
are reversed.
1. Check Bat.(+) and Bat.(-)connect
reversed or not.
2. Make correction If reversed.
B05
PcsBatConnectFault
Battery wires loose
1. Check
battery
wires
and
connectors
damage
or
loose
connect.
2. Carry out rectification if break.
B06
PcsBatComFault
Battery
communication
abnormal
1. Check
battery
side
communication wires damage or
loose connect, and then carry out
rectification.
2. Check battery is off or other
abnormal,
then
Mastertenance
battery or change new battery.
B07
PcsBatTempSensorOpen
Battery temperature
sensor abnormal
1. Check battery temperature
sensor and connected wires damage
or not , then
rectification or
change new one.
B08
PcsBatTempSensorShort
B09
BmsBatSystemFault
All these faults will be
detected or reported
by battery BMS.
1. If specific fault high temperature
or low temperature, then should
change
battery
installed
environment temperature.
2. Restart battery, maybe can
working as normal.
B10
BmsBatVolOverFault
B11
BmsBatVolUnderFault
B12
BmsCellVolOverFault
B13
BmsCellVolUnderFault
B14
BmsCellVolUnbanceFau
Содержание AF3.6K-DH
Страница 14: ...13 4 2 Mounting ...
Страница 17: ...16 Lithium ...
Страница 19: ...18 ...
Страница 22: ...21 Pin BAT NCT CAN 1 TEP T 2 TEP G 3 CAN H 4 CAN L ...
Страница 27: ...26 EPS Connection Generator Connection ...
Страница 49: ...48 8 Specifications Hybrid Inverter ...
Страница 50: ...49 ...
Страница 51: ...50 ...
Страница 52: ...Building 7 No 333 Wanfang Rd Minhang District Shanghai China 201112 Version HH1004 01 ...