46 Operation
4510012 - REV F – 220621
Adjusting Manifold Angle
If desired, the Steam Jets of each Manifold can be angled upward or downward to further
customize how steam is directed.
To Adjust the Angle of the Manifolds:
If not already done, power off the GEN-S and allow the system to cool to 100 °F.
Once the system has cooled, continue to be cautious of heat and steam.
Open all four Manifold Access Doors.
To redirect the angle of the Steam Jets on a Manifold, use a 13 mm Wrench to
loosen the Cap Screws on the Manifold Cuffs on both ends of the desired Manifold
(just inside each opening of the Steam Tunnel).
Rotate the Manifold so that the holes along its length are directed at the desired
angle for steam output.
Use the 13mm Wrench to retighten the Cap Screws when finished
Repeat for any other Manifolds for which a change in Steam Jet angle is desired.
Manifold
Cuffs
Steam
Manifolds
Cap
Screws
AFM-4510012-00050-01
AFM-4510012-00068-01
Rotating the Steam Manifolds
Steam Manifold
(Cross Section)
Steam
Jet
Содержание STC-WSN300-2M
Страница 1: ...WSN GEN S Steam Heat Shrink Tunnel User Guide ...
Страница 2: ...2 Abbreviations 4510012 REV F 220621 ...
Страница 8: ...8 Abbreviations 4510012 REV F 220621 ...
Страница 28: ...28 Introduction 4510012 REV F 220621 STC WSN600 2M GEN S Top View Front View Exit View Entry View ...
Страница 66: ...66 Troubleshooting 4510012 REV F 220621 ...
Страница 67: ...Electrical Schematics 67 4510012 REV F 220621 Electrical Schematics Complete System WSN GEN S ...
Страница 68: ...68 Electrical Schematics 4510012 REV F 220621 Boiler ...
Страница 72: ...72 Parts List 4510012 REV F 220621 Exploded Diagrams Stand Drawing Number YS130EX2 01 ...
Страница 74: ...74 Parts List 4510012 REV F 220621 Tunnel Drawing Number YS130EX2 02 ...
Страница 78: ...78 Parts List 4510012 REV F 220621 Boiler ...
Страница 79: ...Parts List 79 4510012 REV F 220621 Inside Boiler Electrical Cabinet ...
Страница 84: ...84 Technical Support 4510012 REV F 220621 ...