Afikim Afi-lite Plus Скачать руководство пользователя страница 13

February 27, 2003

 

Afi-lite

 User Manual

  

 

7

Cow and Milk Information Accessible from 

Afi-lite

  

Important information on each cow and her milk can be read from the 

Afi-lite

 milk 

meter, where the cow is identified. 

Identification Information 

Cow Number:   

Press

 

 

to see the number of the cow identified at 

the milking point. 

Cow number displays with communication protocol 
C2000 (default protocol): 

If a cow number has more than four digits (ex. 12,345), 
the last four digits are displayed, and a point appears after 
the first digit displayed to indicate there are more digits in 
the cow number. For example: 

2

345

 .  Press and hold 

 to see the first digits of the number.  If the first 

digit is a letter, a “

”  indicates a letter.  For example: cow 

number A123 is displayed as 

123

Group Number:   

Press

 

 

and

 

 

simultaneously to 

see the group number of the cow identified at the 
milking point.

 

Milking Point (Stall) Number:   

Press 

 and 

 simultaneously to 

see milking point number of the 

Afi-lite

 milk meter

.  

Milking Information 

Expected Yield:   

Press 

 and 

 simultaneously to see 

the expected milk yield of the cow at the milking 
point. 

Conductivity: 

Press 

 to see the milk conductivity of the cow 

being milked. 

Expected

 Conductivity:   

An increase in milk conductivity indicates possible 
mastitis.  The 

Afi-lite

 milk meter automatically 

measures the milk's electrical conductivity.  
Conductivity level may be read either during or after 
milking.   

Press 

 and 

 simultaneously to see 

the 

expected

 milk conductivity of the cow. 

Milk Flow Rate (momentary)

:    Press 

 and 

 to see the milk flow 

rate of the present milking, in units (kilograms or 
pounds) per minute.   

Содержание Afi-lite Plus

Страница 1: ...lite Plus Milk Meter Product number 4098999 User Manual http February 27 2003 Kibbutz Afikim 15148 ISRAEL 972 4 675 4811 972 4 675 1862 market afimilk co il www afimilk co il This manual P N 9040310...

Страница 2: ...Afi lite User Manual P N 9040310 b...

Страница 3: ...ine 19 Warnings 19 Recommendations 19 General Instructions 20 Cleaning Cycle 20 Detergent Wash 21 Acid Wash 22 Operation in Cleaning Mode 22 Chapter 4 Milk Meter Body and Fat Sampler 23 The Milk Meter...

Страница 4: ...Afi lite User Manual P N 9040310 d...

Страница 5: ...ment display when starting up has been corrected June 17 2003 6 one sheet Stimulation activation instructions are added July 27 2003 9 10 one sheet When assigned to an animal ALL milking codes 1 8 dea...

Страница 6: ...Afi lite User Manual P N 9040310 f...

Страница 7: ...e following tasks during milking Measures the amount of milk produced Measures conductivity of the milk Controls Automatic Cluster Removal ACR Displays cow information Alerts milkers to health and mil...

Страница 8: ...Afi lite User Manual P N 9040310 2...

Страница 9: ...February 27 2003 Afi lite User Manual 3 The Afi lite milk meter control box Chapter 2 The Milk Meter Control Box This chapter describes operation of the Afi lite milk meter control box...

Страница 10: ...ou to attach the cluster to the jetter while other cows are still being milked The Cancel ACR key Afi lite will detach the cluster automatically when the milk flow rate drops to a predefined level Man...

Страница 11: ...of each Afi lite milk meter This cancels the cleaning mode and the milk meter enters into milking mode 3 Press the key of each milk meter This shuts off the vacuum and retracts the cluster 4 Bring th...

Страница 12: ...press the key to shut off the vacuum and retract the cluster 7 Repeat steps 5 and 6 for each cow While milking is in process the milk yield appears in the display In addition the milker can view the...

Страница 13: ...letter For example cow number A123 is displayed as 123 Group Number Press and simultaneously to see the group number of the cow identified at the milking point Milking Point Stall Number Press and si...

Страница 14: ...taneously to see the number of days that have passed since the cow calved Days after Insemination Press and simultaneously to see the number of days that have passed since the cow was last inseminated...

Страница 15: ...h the cow number For example if cow 1305 has just calved Codes 1 through 8 can be assigned to and canceled from cows from Afi lite milk meters in the parlor Assigning codes is explained in the followi...

Страница 16: ...se a big cluster on a cow with large udders Code 7 is also displayed after cluster removal Therefore this code may be appropriate for situations where milk needs to be diverted such as with cows under...

Страница 17: ...used to designate an antibiotic cow 8 Colostrum cow To see a code during milking press and hold The code alternates with the cow number Alerts Mastitis alert Premature cluster removal Milk yield flas...

Страница 18: ...s are predetermined and they are used to assign a code cancel a code or to send a letter Predetermined Messages As detailed in the table below certain messages specific numbers are predetermined for s...

Страница 19: ...322 The milk meter display returns to its previous reading after the message is entered Example C A message can be sent to delete cancel a code from a cow For example to cancel code 2 from cow 1405 At...

Страница 20: ...Afi lite User Manual P N 9040310 14...

Страница 21: ...he original ID number The identification number of each milk meter is displayed on its control panel with four digits It begins with the letters followed by two numbers For example is the identificati...

Страница 22: ...e of milk from the cow decreases the milk meter body is emptied at greater intervals When the milk meter body is not emptied within the time specified in the cluster is removed Milk flow rate is calcu...

Страница 23: ...ss simultaneously appears for a few seconds Then 1st parameter in the family appears While appears press respective short cut key For press short cut For press short cut For wait a few seconds until i...

Страница 24: ...Afi lite User Manual P N 9040310 18...

Страница 25: ...h chemical detergents Prevent any contact with active detergents and acids in the same container Avoid all contact of pesticide materials with the exterior of AfiFlo milk meter bodies and control pane...

Страница 26: ...d to the jetters During every stage of cleaning check that there is sufficient water to flood the interior chamber of the milk meter bodies The volume of each milk meter body is 500cc The amount of wa...

Страница 27: ...s may be baked onto the surfaces 2 Circulate the water in a closed circuit CIP with detergent Use a basic detergent additive pH 13 and hot water Entry water 70 C 158 F or hotter Returning water 55 C 1...

Страница 28: ...s thereby preventing excessive load on the power supply The schedule creates a delay of 100 msec between stalls and is set according to milking point numbers Every seventh milking point has the same d...

Страница 29: ...te User Manual 23 Chapter 4 Milk Meter Body and Fat Sampler This chapter contains information about The basic structure and components of the AfiFlo milk meter body Silicone and rubber component repla...

Страница 30: ...Meter Body Structure and Components Valve Milk inlet Electrode Electrode Electrode Silicon Diaphragm Milk Outlet Upper Cover and Milk Inlet Upper Gasket Mid Section Lower Cover and Milk Outlet Lower G...

Страница 31: ...ilk portions may vary from 180 250 cc When the solenoid valve is energized vacuum from the solenoid line causes the silicon diaphragm to pull the valve down This releases a portion of the milk Dependi...

Страница 32: ...10 M cable Replace annually 4 AfiFlo body valve gasket 4098072 4098072 4098072 5 AfiFlo body milk valve 4098070 4098070 4098070 6 AfiFlo body lower cover 4098040 4098040 4098040 Replace annually 7 Af...

Страница 33: ...February 27 2003 Afi lite User Manual 27...

Страница 34: ...ilk line Fat Sampler Operation The fat sampler is made up of a sampling bottle and a sampler head Milk is sampled each time the meter body is emptied As the milk flows out of the milk meter body a sma...

Страница 35: ...uctivity and to identify the problem To continue milking from the previous milk measurement 1 Press 2 Reattach the cluster Error Alerts Error alerts flash in the display panel of the milk meter They a...

Страница 36: ...Probable cause Solution Afi lite control box display is not illuminated Power supply cable is not properly connected to the Afi Lite control panel Check and correct When power is turned on Afi lite c...

Страница 37: ...uster removal 29 B back flush assembly 25 F fat sampler 25 arrow on head of 28 mounting 28 M milking point identification number 15 P power supply excess load 22 S single vacuum shut off valve 25 stal...

Страница 38: ......

Страница 39: ......

Отзывы: