AFi RR-984C-SL Скачать руководство пользователя страница 5

 

5

TYPICAL SYSTEM DATA CONNECTIONS 

The RS422 or RS485 four wire interconnection between the RR-984C-SL and the copper device to 
which it is attached is based on industry standard EIA terminology for the transmission of electronic 
data signals. Using this terminology, the driver of an electronic signal is labeled TX or Data Out. 
Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard, 
the TX or Data Out of the copper device is connected to the RX or Data In of the RR-984C-SL. The 
plus terminal of the copper device is connected to the plus terminal of the RR-984C-SL and the minus 
is connected to the minus. The reverse flow of data from the RR-984C-SL to the copper device follows 
the same pattern. Not all manufactures follow standard EIA terminology. Consult the installation 
instructions for your copper device if you are unsure which two wires are the drive (data out) wires and 
which two wires are the received (data in) wires. 

 
DATA CONFIGURATION 

The RR-984C-SL is factory shipped with the data channel configured in the RS485-4 wire  mode.  

 
In order to reconfigure the data channel, the configuration switch bank on the top of the unit needs to 
be modified. 
 
See the tables below for a summary of the switch settings.  

 
Data Switch Off=Up On=Down

 

1 2 3 

4 5 

 

Off 

Off 

Off 

Off 

Off 

RS485-4W / Manchester 

On Off On 

Off Off 

RS485-2W 

Off On Off 

On Off 

RS422 

On On On 

On Off 

RS232 

 

 

RR-984C-SL STATUS INDICATORS 

The RR-984C-SL transmitter provides the following LED status indicators to aid in installation and 
troubleshooting: 

 
DATA TX 

A green LED indicator is provided to monitor the input data from the electrical interface and out onto the 
fiber. The intensity of this indicator will vary with input data patterns. However, in typical applications it 
will cycle on and off as data is transmitted. Data status associated with this LED is summarized below. 
 

Data TX LED 

Data Status 

Green 

Data Flow Present  

Off 

Data Flow Not Detected 

 
DATA RX 

A green LED indicator is provided to monitor the data coming in from the fiber and out onto the 
electrical interface. The intensity of this indicator will vary with input data patterns. However in typical 
applications it will cycle on and off as data is received. Data status associated with this LED is 
summarized below. 
 

Data RX LED 

Data Status 

Green 

Data Flow Present  

Off 

Data Flow Not Detected 

 
 
 

Отзывы: