AFi RR-984C-SL Скачать руководство пользователя страница 3

 

3

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

Thank you for purchasing your American Fibertek RR-984C-SL singlemode eight channel digital video 
receiver with RS485, RS422, RS232, or Manchester data. Please take a few minutes to read these 
installation instructions in order to obtain the maximum performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The RR-984C-SL receiver operates as half of a transmitter / receiver pair for the transmission of eight 
channels of high performance 10 bit digital NTSC, PAL, RS170, or RS343 video signals. The RR-984C-
SL also supports one bi-directional RS485, RS422, RS232 or Manchester data channel. The RS485 
channel may be configured for 2-wire (half duplex) or 4-wire (full duplex) operation. This unit is 
designed for rack mounting into the American Fibertek SR-20/2 subrack. LED indicators provide for 
easy monitoring of video, data, and optical power.  
 
The RR-984C-SL is designed to operate with the MT or RT-984C-SL video transmitter with bi-
directional data over one singlemode fiber optic cable. The RR-984C-SL encodes a data signal into a 
serial data stream that is transmitted on a 1550 nm optical wavelength. The RR-984C-SL also detects 
and demultiplexes a return optical serial data stream containing eight video signals along with one data 
signal at 1310 nm wavelength. Refer to the data sheets for detailed performance specifications 
 

 
 
 
 

INSTALLATION 

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD 
CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. 
  
The unit slides into any two adjacent open slots in the SR-20 subrack. Use a small screwdriver to push 
and lock the four ¼ turn fasteners into place. 
 

 

POWER SOURCE 

Power to the unit is supplied by the subrack. Please refer to the SR-20/SR20D and PSR-2 instructions 
for further details. 

 
POWER CONNECTION 

Power is supplied to the unit via a backplane connector. The RR-984C-SL can be inserted into the 
subrack or removed from the subrack with power applied to the backplane. 

 
FIBER CONNECTION 

The fiber optic connection is made via a FC/PC connector located on the back of the unit. Be sure to 
allow sufficient room for the required minimum bend radius of the fiber cable used. 