16

Factory default IP

The N-111 is factory programmed with the following default network settings:

IP address

192.168.10.11

Netmask

255.255.255.0

Gateway

192.168.1.1

DNS

None programmed

If the N-111 has not had its IP address changed by the user it will be possible to connect
to it at this network address. If you do not know the IP address of the unit, you can reset
the unit back to factory defaults and then connect at the default address.

Содержание N-111

Страница 1: ...1 Net I O N 111 User s Manual Revision 8 2 2013...

Страница 2: ...ed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract EXCEPT FOR THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITN...

Страница 3: ...13 Factory default IP Reset sequence NTP timeserver configuration Operating modes 17 Overview Serial Server Mode Serial Client Mode Alarm input forwarding Aux outputs Pilot interface Web Interface 22...

Страница 4: ...4 Ethernet Serial Aux Alarm...

Страница 5: ...5 1 Introduction Overview Package Checklist Product Features Product Specifications...

Страница 6: ...card registers to send data to a remote monitoring system N 111 devices can be linked together over a standard Ethernet connection making it possible to use a pre existing LAN or the Internet for dev...

Страница 7: ...s Connector type Screw terminal Power input voltage 12 VDC Power required 5W maximum POE class Class 0 POE type 802 3af Mechanical Dimensions 4 43 x 4 175 x 1 125 113mm x 106mm x 29mm Weight 8 oz 0 22...

Страница 8: ...8 2 Getting Started Panel Layout Connecting the Hardware LED indicators Real time clock...

Страница 9: ...ting power with incorrect polarity may damage the N 111 The N 111 is also capable of being powered over the network connection through 802 3af Power over Ethernet PoE To power a N 111 over POE connect...

Страница 10: ...RS485 four wire To connect to a serial port in RS485 4 wire mode you will need a DB9 connector wired as indicated Four connections will need to be made for the two data transmit lines and the two dat...

Страница 11: ...11...

Страница 12: ...ion web page if an alarm condition will correspond to the connection being made or the connection being broken To connect an alarm source such as a door switch or motion detector to the N 111 use two...

Страница 13: ...Tighten the terminal screws to secure the wires in the terminal block Aux Contact Out When an output is not active the Common terminal will be electrically connected inside the N 111 to the Normally...

Страница 14: ...s the status of the aux contact output During initial powering up of the unit this LED will briefly flash green then red for a moment It will then be illuminated green if the aux contact output is act...

Страница 15: ...15 3 Initial IP configuration Factory default IP Reset sequence NTP timeserver configuration...

Страница 16: ...11 Netmask 255 255 255 0 Gateway 192 168 1 1 DNS None programmed If the N 111 has not had its IP address changed by the user it will be possible to connect to it at this network address If you do not...

Страница 17: ...set the N 111 perform the following steps Disconnect power from the N 111 With a paperclip or other small object press and hold the reset button recessed in the rear of the unit Connect power to the N...

Страница 18: ...ersal Time UTC This battery backed time and date setting can be updated by regular Network Time Protocol NTP packets from a server connected to the same network as the N 111 Alternately the N 111 can...

Страница 19: ...19 4 Operating modes Overview Serial Server Mode Serial Client Mode Alarm input forwarding Aux outputs Pilot interface...

Страница 20: ...be point to point communication between to devices while contacts can be set to trigger various actions locally or remotely as desired Each serial port or contact input or output can be configured ind...

Страница 21: ...he N 111 has a contact input which can be connected to customer supplied contact closure devices such as motion detectors or door switches This alarm input can be linked through the N 111 to trigger t...

Страница 22: ...tes of all alarm and aux status These messages can trigger events in the CMS Pilot Software Aux outputs The N 111 makes an aux contact output available to devices on the network Any device on the netw...

Страница 23: ...external piece of network connected equipment and on detection of a failure trigger an alarm notify a technician or power cycle an external device through a relay Pilot interface The N 111 is intended...

Страница 24: ...24 5 Web Interface Connecting to the N 111 Interface layout Operator setup Global settings IP Ethernet Setup NTP Setup Alarm Setup Aux Setup Communications Watchdog Upload Firmware SNMP Reboot Net I O...

Страница 25: ...a User Name and Password to access the unit note need to fix this to have the right address and username password The default User Name and Password are Admin and Password respectively It is strongly...

Страница 26: ...led Save and Default The Save button at the bottom of each screen will cause the specific settings on that screen to be saved to the N 111 s nonvolatile configuration files and then will return the us...

Страница 27: ...ion are required It is recommended that you change these from the default settings Changes to this page take place immediately If you change the username or password and save changes you will then hav...

Страница 28: ...Pilot servers The Global Settings screen also permits the user to change which authentication will be used for the API The user may select for the fixed internal username and password to be used or fo...

Страница 29: ...nter the new IP address in the browser address bar to reconnect to the unit Changes to the IP address or subnet mask will also cause any active Pilot or serial port network connections to disconnect T...

Страница 30: ...how if the N 111 has successfully connected to that server In order to send email notifications the N 111 needs to connect to an SMTP mail server The server may be an IP Address or mail server URL In...

Страница 31: ...te over time so this mode is not recommended If Accept NTP Broadcast is selected the N 111 will update its time and date settings every time it received a NTP broadcast packet on the network This is t...

Страница 32: ...stered when the two contact inputs are not shorted to each other The default mode is Normally Open The Supervision setting selects if the alarm input is a normal contact closure or a supervised contac...

Страница 33: ...33 selected the N 111 will not trigger an alarm until the input has been maintained continuously for that duration...

Страница 34: ...message This feature can be individually enabled or disabled for each alarm input Remote Aux Actions Address indicated the network IP address of the target device This may be up to 15 characters long...

Страница 35: ...duration will simply cause the N 111 to set the target aux contact ON or OFF once and leave it so set Buttons are provided which force an ON or OFF message to be sent to the indicated remote aux outp...

Страница 36: ...e behavior causing the targeted aux to go OFF when the local alarm is triggered and ON when it is not Selecting Indefinitely for the duration will simply cause the N 111 to set the target aux contact...

Страница 37: ...succeeded in contacting the target unit not from when the alarm was triggered Thus if a N 111 is set to set a specific aux contact out ON for 5 seconds when an alarm input is triggered and it takes 3...

Страница 38: ...appropriate trap message This feature can be individually enabled or disabled for the aux contact As each contact output has terminals for normally closed and normally open there is no setting to chan...

Страница 39: ...h no connection to the network The hardware baud rate for each port can be selected from 0 to 57600 bps This controls the rate at which the hardware port receives and transmits data It does not affect...

Страница 40: ...ether The serial port function of the N 111 is intended to be used with two or more N 111 devices on a network where a serial port on one N 111 is linked to a serial port on another N 111 The only res...

Страница 41: ...onnection as quickly as it is received During conditions of heavy network activity or high latency the buffer may become full When this occurs some data may be lost Data coming from the remote unit ov...

Страница 42: ...response for a ping it will increment a counter which records the number of consecutive failed pings A single successfully received ping response will set this counter to zero When a number of failed...

Страница 43: ...in dotted quad format followed by a colon followed by a port number in the range of 0 to 32767 The default setting of 0 0 0 0 23 indicates no action to be taken The TCP Message field holds a text mes...

Страница 44: ...ry file will appear in the text box Press the Upload button to start uploading the new binary file The file upload may take up to a minute to complete Once it has competed you should see either a scre...

Страница 45: ...ontact on or off The names of the communities must mach the community names set in the user s management software This enables a degree of security for controlling contacts or changing warning levels...

Страница 46: ...is used When the N 111 is being reset the aux contact output turn OFF until the reset cycle is completed at which time it will behave as configured on the Aux Setup page Any messages to change aux ou...

Страница 47: ...47 A Pinouts and connectors Power Ethernet Serial Aux Alarm...

Страница 48: ...RX 4 N C 5 N C 6 RX 7 N C 8 N C Serial RS232 Pins 1 Data Carrier Detect DCD 2 Receive Data RD 3 Transmit Data TD 4 Data Terminal Ready DTR 5 Ground 6 Data Set Ready DSR 7 Request To Send RTS 8 Clear...

Страница 49: ...mit Data Negative TX 4 Not connected 5 Ground 6 Not connected 7 Transmit Data Positive TX 8 Receive Data Negative RX 9 Not connected Aux Alarm Pins 1 Aux Contact Common 2 Aux Contact Normally Closed 3...

Страница 50: ...chnical Assistance If any questions arise concerning the installation of American Fibertek products please allow us to assist you by calling faxing or by E mail Phone 732 302 0660 FAX 732 302 0667 tec...

Страница 51: ...51...

Отзывы: