Dear customer,

Thank you for choosing this product and the trust you have placed in us with your purchase. To
ensure that you are able to fully utilize all of the advantages offered by our product, we have
compiled the information you will need in order to optimally use your AffloVest in this manual. To
ensure the safe use of this device, please pay particular attention to all of the points identified in
this booklet.

The instructions for use also contain important information on SAFETY and TECHNICAL

DATA. You should therefore carefully read the instructions before using the device for the first

time and keep these instructions in a safe place for future reference.

With proper maintenance and care, you will be rewarded by your AffloVest with a long service
life and trouble-free operation of our product. We greatly value the satisfaction of our customers
and hope you are happy with your AffloVest by IBC.

CONTENTS

Explanation of Symbols ..........................................................................................

Page 4

Technical Data ................................................................................................................... Page 5
User Information ................................................................................................................ Page 6

Purpose/Method/Application .............................................................................................. Page 6
Starting the AffloVest in Battery Mode ............................................................................... Page 7
Battery Warning Information .............................................................................................. Page 8
Technology and Design ..................................................................................................... Page 8
Buttons and Functions ...................................................................................................... Page 9/10

Body Zones ....................................................................................................................... Page 10
Test Regulations for Commercial/Clinical Use .................................................................. Page 11

Safety Information ............................................................................................................. Page 11
Guarantee of the Battery Pack .......................................................................................... Page 12
Environmental Protection .................................................................................................. Page 13
Turning Off Device............................................................................................................. Page 13
Cleaning and Care ............................................................................................................ Page 13
Troubleshooting ................................................................................................................ Page 14
Electromagnetic Guidelines for Clinical Applications ........................................................ Page 15/17

Содержание RP8001

Страница 1: ......

Страница 2: ...it Charger RP8001 Rechargeable Battery RP8003 AffloVest L RP8300 M RP8200 S RP8100 Carrying Case RP8005 AffloVest Instructions for Use Adapter Cable for D C Operation RP8002 g y Aff ff f loVe Ve V st...

Страница 3: ...place for future reference With proper maintenance and care you will be rewarded by your AffloVest with a long service life and trouble free operation of our product We greatly value the satisfaction...

Страница 4: ...Charger Test and Identification Symbols RP8003 Battery Pack Not for Outdoor Use T V Rheinland Approval In Accordance with EN60601 1 and IEC 60601 1 Communan Europ enne European Community Directives g...

Страница 5: ...A Nominal Voltage Nominal Power Consumption Power Supply Unit Charger Lithium Polymer Battery Pack Manufacturer Distributor Sizes 12V DC Approx 30W Model RP 8001 INPUT 100 240V AC 50 60 Hz OUTPUT 12V...

Страница 6: ...proceduresonorinjuriestothespinal column The AffloVest is intended for promoting airway clearance and improvement of bronchial drainage by enhancing mobilization of bronchial secretions where external...

Страница 7: ...ry has reached its maximum charge disconnect it from the charger and connect it to the AffloVest It is not recommended to start a new cycle if more than half of the LED lights on the battery are not i...

Страница 8: ...nductive surface Lithium Polymer batteries that are totally discharged are defective and must no longer be used Do not expose the battery pack to direct sunlight The maximum permissible ambient temper...

Страница 9: ...level of intensity Programs P1 P2 and P3 always start with SOFT intensity Note The intensity automatically switches to SOFT when changing the programs P1 P2 and P3 You can then freely select your chos...

Страница 10: ...functions are available again after pressing any button The LED lights P1 P2 or P3 on the hand held controller light up to indicate the currently active program The LED lights 1 5 show which oscillati...

Страница 11: ...ns The use of any other power supply units and chargers can lead to fire and electric shock Overcharging must be avoided Pay attention to the voltage ratings on the power supply unit The device is des...

Страница 12: ...epairs shall not extend the warranty period Incorrect use or operation e g incorrect charging or excessively high discharge rates shall invalidate any guarantee claims The same applies to defects caus...

Страница 13: ...ailed information at your nearest collection point for recyclable materials from your local authority Recycling instead of waste disposal Devices accessories and packaging should be recycled only for...

Страница 14: ...ly fuse defective or automatic circuit breaker tripped Power Failure Standby Mode Plug in correctly Plug in power plug and or Plug in charge battery Needs to be repaired by an IBC authorized electrici...

Страница 15: ...ive humidity should be at least 30 Fast Electrical Transients Bursts as per IEC 61000 4 4 2 kV for Power Supply Lines 1 kV for Input Output Lines Mains power quality should be that of a typical commer...

Страница 16: ...The higher frequency range applies at 80 MHz and 800 MHz NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorbtion and reflection from structures o...

Страница 17: ...Transmitter Output W 150 kHz to 80 MHz d 1 2 m P 80 MHz to 800 MHz d 1 2 m P 800 MHz to 2 5 GHz d 2 3 m P 0 01 0 1 1 10 100 0 12 1 2 0 38 3 8 12 0 12 0 23 0 38 0 73 1 2 2 3 3 8 7 3 12 23 The recommend...

Отзывы: