AES 7058E Скачать руководство пользователя страница 8

AES 7058E RF Subscriber Unit -- Installation and Operation Manual 

AES Corporation 

P/N 40-7058E Rev 2.1 11/11/2014

 

 

► 

OWNER WARRANTY – AES CORPORATION 

LIMITED PRODUCT WARRANTY AND 

TECHNOLOGY LICENSE 

LIMITED PRODUCT WARRANTY: 

AES Corporation (“AES”) warrants to the original purchaser 
that each AES Subscriber Product will be free from defects in 
material and workmanship for three (3) years from date of 
purchase and all other products purchased from AES including 
central station receivers and accessories will be warranted for 
one (1) year from the date of purchase.  At no cost to the original 
purchaser for parts or labor, AES will repair or replace any AES 
Product or any, part or parts thereof which are judged defective 
under the terms of this Warranty. 

Defective  AES  Products  must  be  returned  to  AES  directly, 
provided  they  are  properly  packed,  postage  prepaid.    Or 
exchange  may  be  made  through  any  authorized  direct  factory 
representative  for  any  AES  Products  that  are  judged  defective 
under  the  terms  of  this  Warranty.    Improper  or  incorrectly 
performed  maintenance  or  repair  voids  this  Warranty.    This 
Warranty does not cover replacement parts that are not approved 
by AES.  This Warranty does not  apply to any AES Product or 
any  part  thereof  that  has  been  altered  in  any  way  to  affect  its 
stability  or  reliability,  or  that  has  been  subjected  to  abuse, 
misuse,  negligence,  accident  or  act  of  God,  or  that  has  had  the 
serial number effaced or removed. 

Certain AES Products are designed to operate and communicate 
with  other  specified  AES  Products  and  certain  other  specified 
products, systems  or  networks  authorized  or  approved  by  AES, 
as  identified  in  the  applicable  AES  Product  instructions.    This 
Warranty  does  not  apply  to  any  AES  Product  that  is  used  with 
any unauthorized or unapproved products, systems or networks, 
or that has been installed, applied or used in any  manner, other 
than in strict accordance with AES instructions. 

AES makes no warranty, express or implied, other than what is 
expressly  stated  in  this  Warranty.    If  the  law  of  your  state 
provides  that  an  implied  warranty  of  merchantability,  or  an 
implied  warranty  of  fitness  for  particular  purpose,  or  any  other 
implied  warranty,  applies  to  AES,  then  any  such  implied 
warranty is limited to the duration of this Warranty. 

AES cannot be aware of and is not responsible for the differing 
values  of  any  property  to  be  protected  by  its  alarm  reporting 
systems.    This  Warranty  does  not  cover  and  AES  shall  not  be 
liable for any defect, incidental or consequential, loss or damage 
arising out of the failure of any AES Product to operate. 

Some  states  do  not  allow  the  exclusion  or  limitation  of  the 
durations of implied warranties or the limitation on incidental or 
consequential  damages,  so  the  above  limitations  or  exclusions 
may not apply to you. 

This Warranty gives you specific legal rights and you may also 
have other rights that vary from state to state. 

TECHNOLOGY LICENSE: 

Certain  AES  Products  include  software,  protocols  and  other 
proprietary and confidential technology and trade secrets of AES 
which are incorporated in or provided with AES Products solely 
for use in conjunction with and in order to operate AES Products 
(“Licensed  Technology”).    AES  grants the  original purchaser a 
non-exclusive license to use such Licensed Technology solely in 
connection with the use and operation of AES Products and for 
no other purpose or use whatsoever.  No title or ownership in or 
to  any  such  Licensed  Technology  is  conveyed  by  the  sale  or 
delivery  of  any  AES  Products;  all  such  rights  are  retained  by 
AES. 

Warranty Rev date June 2007

 

 

► Troubleshooting 

The most common causes of an RF failure or trouble are due to 
issues  with  the  transmission  line  including  but  not  limited  to 
the  antenna  type,  antenna  location,  coax,  connectors,  and 
transceiver.    Antennas  in  close  proximity  to  metal  or  with 
conductive  material  blocking  or  reflecting  the  transmitted 
signal would be at the top of the list.  Observe the RX light on 
the  7058E.    If  it  is  on  steady  or  most  of  the  time  you  may  be 
receiving  some  RF  or  electrical  interference.    Try  different 
locations  for  the  antenna  or  use  a  remote  long  range  RF 
antenna.  Try replacing transmission line components such as a 
new transceiver, the coaxial connectors, coax and antenna. 
Problems  on  the  circuit  boards  usually  require  returning  the 
defective unit to AES for service. Antennas should be mounted 
at  least  5-10  feet  above  the  roof  line  on  roofs  containing 
significant metal surface.

 

► Maintenance 

Once  installed  and  normal  operation  is  confirmed,  there  is 
typically little maintenance required.  Monitoring the automatic 
test  messages  will  confirm  proper  RF  operation.    Batteries 
should be periodically tested to be certain they have sufficient 
capacity to operate the system as needed.

 

 

AES SERVICE PROCEDURE: 

Contact AES by Phone (978) 535-7310, Fax (978) 535-
7313 or Email [email protected], to receive a 
Return Material Authorization Number.  Have the AES 
part number and serial number ready.  Repack 
equipment in original or equivalent packaging.  Inside the 
box, please include a contact name, telephone number, 
address and a brief description of the reason for return.

 

Ship items freight-prepaid to: 

 

 

 

Repair Services, RMA#_____ 
AES Corporation, 
285 Newbury Street 
Peabody, MA 01960 USA  
 

(Contact AES for Return Material Authorization number) 

 

 

FCC Identification: AES Model 7058E Subscriber Unit 

 

This unit complies with FCC part 68 as of date of manufacture.  
FCC# 5IWUSA-47000-MO-N Ringer Equivalence 0.0B Jack: Barrier Block 

• FCC COMPLIANCE 

 

NOTE: This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following measures: Reorient 
or relocate the receiving antenna; Increase the separation between the equipment 
and the receiver; Connect the equipment into an outlet on a circuit different from 
that to which the receiver is connected; Consult the dealer or an experienced 
radio/TV technician for help. CAUTION: Changes or modifications to this 
equipment not expressly approved by the party responsible for compliance could 
void the user’s authority to operate the equipment.  

• CANADIAN COMPLIANCE 

 

This digital apparatus does not exceed the Class B limits for radio noise 
emissions from digital apparatus as set out in the interference-causing equipment 
standard entitled "Digital Apparatus", ICES-003 of Industry Canada.  
Cet appareil numérique respects les limites de bruits radio électriques 
applicables aux appareils numériques de Classe B prescrites dans la 
norme sur le matériel brouilleur: "Appareils Numeriques", NMB-003 
édictés par l'Industrie Canada.  

 

Содержание 7058E

Страница 1: ... ALARM SIGNAL INPUTS 8 individually programmable Zones NO NC Supervised EOL Fire EOL Trouble and Restore BACK UP BATTERY 12V up to 7 5AH max lead acid gel type LOW BATTERY REPORTING Below 11V 22 5 Minute Test Cycle approx AC STATUS REPORTING Detects AC Fail Restore in less than a min without with AC Report to central station after detection is 100 minutes plus transmission delay 0 60 minutes rando...

Страница 2: ...3 J1 Programmer External Module connector Plug programmer s cable into this jack to perform programming functions The internal supply voltage of the 7058E will power programmer The AES IntelliPro or IntelliTap or other supported accessories are connected and powered by this jack Any attached module must be disconnected to connect the programmer and the programmer must be disconnected to use an acc...

Страница 3: ...use is recommended between J4 and the relay The pin is switched to ground by an internal transistor Maximum load is 200 mA Status LED Indicators LED Indicators on Circuit Board There are 4 LED s on the main circuit board of the 7058E The function of each is described below TX Red indicates radio transmit RX Green Indicates radio receive includes any radio activity on this frequency strong enough t...

Страница 4: ...080 004 Except for the low battery fault and AC Fail most other persistent fault messages may indicate that the unit requires AES authorized servicing Report the error code to AES service rep Programming the Unit Programming is accomplished by attaching a compatible programmer to the J1 connector on the 7058E Smart Controller board Following are programming instructions using the AES 7041 Hand Hel...

Страница 5: ... entered correctly the following message appears COMM TIMEOUT OLD NEW ENTER SECS 121 Enter Comm Delay time in 60 300 Seconds 120 is default Then Press ENTER This is the delay before ACK delay is reported OK Timing parameter programming complete Zone Programming Factory default zone programming is set to EOL Supervision S without restore X If this is satisfactory skip to the next section To start p...

Страница 6: ...he 7058E repeating capability Default is Y Press ENTER the following appears SPRSS ACFAIL N Enter a Y to suppress the reporting of AC Fail and Restore messages Enter N to allow AC Fail reporting Default is N which will result in the reporting of AC Fail and Restoral Messages to central station OK is displayed when Set Modes is Complete Program ID and System Cipher Code The unit ID and the system c...

Страница 7: ...to determine adequate signal strength quick reception of messages and acceptable routing Refer to separate Net7000 or MultiNet software manuals for use of testing functions Programming the Subscriber Unit from a PC In place of a handheld terminal a cable adapter kit 7043 may be ordered from AES to link the 7058E to your computer s serial port Use a terminal program like Hyper Terminal or Telix to ...

Страница 8: ...ucts all such rights are retained by AES Warranty Rev date June 2007 Troubleshooting The most common causes of an RF failure or trouble are due to issues with the transmission line including but not limited to the antenna type antenna location coax connectors and transceiver Antennas in close proximity to metal or with conductive material blocking or reflecting the transmitted signal would be at t...