AES 7058E Скачать руководство пользователя страница 3

AES 7058E RF Subscriber Unit -- Installation and Operation Manual 

AES Corporation 

P/N 40-7058E Rev 2.1 11/11/2014

 

► 

Wiring – Antenna Cut / 

Acknowledge Delay Output (J4) 

If the radio channel is "quiet" for more than 6 minutes (as 
would be the case if the antenna was cut) the 7058E subscriber 
attempts to send a test message to another subscriber.  If that 
message is not acknowledged within the programmed 
acknowledgment delay period (default is 2 minutes), a fault 
condition exists.  This fault condition is annunciated at J4, 
which is a 12V open collector output.  The pin closest to the 
heat sink grounds on activation.  The pin closest to the LEDs 
is connected to +12V.  (See diagrams below).  The voltage 
can be used to drive a relay, sounder or other device to notify 
someone of the condition.  Maximum load is 200 mA.  An 
“Acknowledge Delay” message is also added to the transmit 
queue to be sent when the unit re-connects to the network. 
(Seen as an R356 E903 or T903 in automation)

 

The (+) pin of J4 is internally connected directly to the 12 
Volt supply. A fuse is recommended between J4+ and the 
relay. 
The (–) pin is switched to ground by an internal transistor. 
Maximum load is 200 mA.

 

 

 

► 

Status (LED) Indicators 

 

LED Indicators on Circuit Board

 

There are 4 LED’s on the main circuit board of the 7058E.  
The function of each is described below. 

TX     

   (Red) indicates radio transmit 

RX    

   (Green) Indicates radio receive  (includes any 

radio activity on this frequency strong enough to 
break squelch) 

WA  

   (Yellow) Steady On = Waiting for 

acknowledgment of last transmission; 

 

Steady Blinking = Not on Network; Off = Normal 

ALM 

  (Red)  Status  /  troubleshooting  indicator,  

See “…Blink Patterns” below 

 

► 

Red ALM LED, Blink Patterns

 

Blink Codes: “●” = short  “▬“ = long. Period between 
patterns is about 1 second with diagram showing 3 repeats. 
|1 second| 
● 

● 

● 

Steady blink – System OK; 

●● 

●● 

●● 

Short-Short blink – low battery; 

●▬ 

●▬ 

●▬ 

Short-long blink – an input is in 
alarm or trouble 

●●▬  ●●▬  ●●▬  Short-short-long blink – low batt 

& zone in alarm or trouble 

●  ●●  ●  ●●  ●  ●●  short-pause-short-short, AC Fault 
●●  ●●  ●●  ●●  ●●  ●● short-short-pause-short-short,  

AC Fault and low battery 

▬▬▬▬▬▬▬▬▬  Steady / no blink – Self test fail 

(Excluding low battery) 

► Parts List 

The standard 7058E RF Subscriber includes the following 
items. 

 

Transceiver,  Part  number  varies  (7085-UE5  is  most 
common) 

 

7214 UHF Tamper Resistant Antenna Assembly 

 

40-7450-S Instruction manual 

 

Содержание 7058E

Страница 1: ... ALARM SIGNAL INPUTS 8 individually programmable Zones NO NC Supervised EOL Fire EOL Trouble and Restore BACK UP BATTERY 12V up to 7 5AH max lead acid gel type LOW BATTERY REPORTING Below 11V 22 5 Minute Test Cycle approx AC STATUS REPORTING Detects AC Fail Restore in less than a min without with AC Report to central station after detection is 100 minutes plus transmission delay 0 60 minutes rando...

Страница 2: ...3 J1 Programmer External Module connector Plug programmer s cable into this jack to perform programming functions The internal supply voltage of the 7058E will power programmer The AES IntelliPro or IntelliTap or other supported accessories are connected and powered by this jack Any attached module must be disconnected to connect the programmer and the programmer must be disconnected to use an acc...

Страница 3: ...use is recommended between J4 and the relay The pin is switched to ground by an internal transistor Maximum load is 200 mA Status LED Indicators LED Indicators on Circuit Board There are 4 LED s on the main circuit board of the 7058E The function of each is described below TX Red indicates radio transmit RX Green Indicates radio receive includes any radio activity on this frequency strong enough t...

Страница 4: ...080 004 Except for the low battery fault and AC Fail most other persistent fault messages may indicate that the unit requires AES authorized servicing Report the error code to AES service rep Programming the Unit Programming is accomplished by attaching a compatible programmer to the J1 connector on the 7058E Smart Controller board Following are programming instructions using the AES 7041 Hand Hel...

Страница 5: ... entered correctly the following message appears COMM TIMEOUT OLD NEW ENTER SECS 121 Enter Comm Delay time in 60 300 Seconds 120 is default Then Press ENTER This is the delay before ACK delay is reported OK Timing parameter programming complete Zone Programming Factory default zone programming is set to EOL Supervision S without restore X If this is satisfactory skip to the next section To start p...

Страница 6: ...he 7058E repeating capability Default is Y Press ENTER the following appears SPRSS ACFAIL N Enter a Y to suppress the reporting of AC Fail and Restore messages Enter N to allow AC Fail reporting Default is N which will result in the reporting of AC Fail and Restoral Messages to central station OK is displayed when Set Modes is Complete Program ID and System Cipher Code The unit ID and the system c...

Страница 7: ...to determine adequate signal strength quick reception of messages and acceptable routing Refer to separate Net7000 or MultiNet software manuals for use of testing functions Programming the Subscriber Unit from a PC In place of a handheld terminal a cable adapter kit 7043 may be ordered from AES to link the 7058E to your computer s serial port Use a terminal program like Hyper Terminal or Telix to ...

Страница 8: ...ucts all such rights are retained by AES Warranty Rev date June 2007 Troubleshooting The most common causes of an RF failure or trouble are due to issues with the transmission line including but not limited to the antenna type antenna location coax connectors and transceiver Antennas in close proximity to metal or with conductive material blocking or reflecting the transmitted signal would be at t...

Отзывы: